Tender For supply of layer 2 access switch non poe,layer 2 access switch poe,sfp pluggable transceiver,monitoring and analyzer,network policy controller,12u rack enclosures networking,zero u pdu,aggregated power management unit,video conferencing camera,microphone with speeker,edge computing device,h res av cable,high speed data and control cable,storage media centre,multi viewer with av switching and control,dome camera,16 channels nvr,access control system,power conditioning and surge protection unit,cat 6 information outlet,cat 6 u-utp patch panel,cat 6 u-utp patch cord 1 mtr,cat 6 uutp patch cord 2 mtr,cat 6 u-utp cable,cat 6 cable for outdoor,fiber optic patch cord lc-sc,single mode fiber cable,splice closure for optical fiber cable,pvc channel 25mm,pvc channel 50 mm,pvc copper cable,power socket with electrical switch,cable pulling pit,underground trenching, laying of foc and restoration of ground,installation, testing, commisioning and integration
Tender For supply of electrical items for repair and maintenance of electrical installation at iiser bhopal - supply of 22 (+/-2) watt led tube light betten t-5 made of aluminium/pc body with pc diffuser with inbuilt driver for proper driving of leds. the minimum system lumen output 100lm/watt, and p.f>0.9. the cct of led used should be between 5700k to 5000k only. (make: havells/crompton/philips/wipro/orient/panasonic/ jaquar)., supply of 10 (+/-2) watt led tube light betten t-5 made of aluminium/pc body with pc diffuser with inbuilt driver for proper driving of leds. the minimum system lumen output 100lm/watt, and p.f>0.9. the cct of led used should be between 5700k to 6000k only. (make: havells/crompton/philips/wipro/orient/panasonic/jaquar)., supply of 38 (+/-2) watt recessed mounted 2x2 feet led light fitting with pc diffuser with inbuilt driver for proper driving of leds. the minimum system lumen output 100lm/watt and p.f>0.9, up to 2 kv surge protection. the cct of led used should be between 6000k to 6500k only (make-havells/crompton/philips/wipro/orient/ panasonic/jaquar), supply of 38 (+/-2) watt surface mounted 2x2 feat led light fitting with pc diffuser with inbuilt driver for proper driving of leds. the minimum system lumen output 100lm/watt and p.f.> 0.9, up to 2 kv surge protection. the cct of led used should be between 6000k to 6500k only (make-havells/crompton/philips/wipro/orient/ panasonic/jaquar)., supply of surface mounted ceiling light 18 watt led light fitting with pc diffuser with inbuilt driver for proper driving of leds. the minimum system lumen output 100lm/watt and p.f. 0.9, up to 2 kv surge protection. the cct of led used should be between 6000k to 6500k only (make:-havells/crompton/philips/ wipro/orient/ panasonic/jaquar)., supply of recessed mounted (11) ceiling light 22 (+/-2 watt led light fitting with pc diffuser with inbuilt driver for proper driving of leds. the minimum system lumen output 100lm/watt and p.f 0.9, up to 2 kv surge protection. the cct of led used should be between 6000k to 6500k only. (make-havells/crompton/philips/wipro/orient/ panasonic/jaquar), supply of surface mounted motion sensor ceiling light 10 watt led light fitting with inbuilt driver for proper driving of leds. the minimum system lumen output 100lm/watt and pf>0.9, up to 2 kv surge 6000k to protection. the cct of led used should be between (make-havells/crompton/philips/wipro/orient/ panasonic/jaquar) 6500k only, supply of 10 watt (+/-2 watt) bulkhead light fitting with inbuilt driver for proper driving of leds. the minimum system lumen output 100 im/watt and p.f>0.9, up 10 2 kv surge protection. the cct of led used should be between 6000k to 6500k only. (make:-havells/crompton/philips/ wipro/orient/ panasonic jaquar), supply of 10 watt track (study lamp) light fitting with inbuilt driver for proper driving of leds. the minimum system lumen output 100 im/watt and p.f>0.9, up to 2 kv surge protection. the cct of led used should be between 6000k to 6500k only. (make: havells/crompton/philips wipro/orient/ panasonic/jaquar), supply of 45 watt (+/-2 watt) streetlight fitting with inbuilt driver for proper driving of leds. the minimum system lumen output 100 lm/watt and p.f. 0.9, up to 2 kv surge protection. the cct of led used should be between 6000k to 6500k only. (make: havells/crompton/philips wipro/orient/ panasonic/jaquar), supply of aesthetically designed post top led luminaire smd of 40 w+ 5%, rated voltage 240v ac, 50 hz. ip 65 protection, system lumen efficacy > 90 lumens/w, voltage range 140-270 v ac, pf 20.95, cct: 5700k-6500 k, thd-10%, cri->70, operating temperature 0°c to 50°c, (make havells/crompton/philips/wipro/orient/panasonic/ jaquar)., supply of aesthetically designed tripod style inverted pyramid bollard of 0.8m to 0.9m heighted led light of 10 (+/-) 2 w at 230 v ac operation, ip 65 protection, voltage range 150-260 v ac, pf>0.9, cct: 5400k 6500k, surge protection 4.5kv made up of aluminium casting with acryli
Tender For corrigendum : supply and installation of high mast signages including design, manufacturing, supply, transportation, installation and commissioning of the complete high mast signage, display panels, civil foundation works, earthing and lightningprotectionsystem
Tender For supply of sitc of lightningprotectionsystem d d -sitc of piezo electric ese air terminal , sitc of type 1 spd class b , sitc of type 2 spd class c , sitc of type 3 spd class d , supplying and drawing of 6 sqmm of frls pvc , p and l earth connection from earth electrode , chemical earthing
Tender For corrigendum : providing of custom bid for services - earthing and lightningprotectionsystem adequacy study for switchyard, main plant and off site areas at ntpc dadri thermal
Tender For supply of for training , providing and supplying of halogen lamp set with stand for illumination of solar panels in lab ac mains operated to provide 0 to 1000 watts per meter square , providing and supplying of motorized bench grinder ac mains operated , providing and supplying of battery charger 0 6 9 12 24 48 v 30amp , providing and supplying of solar photovoltaic module set 75 w mono crystalline module 75 w amorphous silicon module 250 w thin film module 5w 10w 40w poly crystalline module set of , providing and supplying of solar panels 250 wp , providing and supplying of solar charge controller with dusk to dawn automatic switching 12v 10a , providing and supplying of solar charge controller with manual switch day lighting 12 v 10 a , providing and supplying of array junction box for connecting 250w x 4 nos solar panel with dc fuse dc mcb and surge suppressor protection , providing and supplying of solar lantern led type , providing and supplying of solar lantern cfl type , providing and supplying of solar lantern assembly sets , providing and supplying of home light system 12 v dc with fm receiver led bulb and mobile charger as loads , providing and supplying of solar cell kit , providing and supplying of clinometer for angle measurement , providing and supplying of spirit level for floor level check , providing and supplying of anemometer for wind speed measurement , providing and supplying of dc table fan 12 v , providing and supplying of ac voltmeter mi 0 , providing and supplying of volt meter 0 30v , providing and supplying of volt meter 0 100v , providing and supplying of ammeter mc 0 1a , providing and supplying of ammeter mc 0 5a , providing and supplying of ammeter mc centre zero 0 20a , providing and supplying of ammeter mc centre zero 050a , providing and supplying of power factor meter , providing and supplying of rheostat set 0 1 ohm 5 amp 0 10 ohm 5 amp 0 25 ohm 1 amp 0 300 ohm 1 amp set , providing and supplying of ac energy meter single phase 10 a 240 v inductiontype , providing and supplying of ac energy meter three phase 15 a 440 v induction type , providing and supplying of kilo wattmeter analog 0153kw pressure coil rating 240v440v current rating5a10a analog portable type housed in bakelite case , providing and supplying of digital wattmeter 230 v 1 kw 50 hz , providing and supplying of phase sequence indicator 3 phase 415 v , providing and supplying of frequency meter 45 to 55 hz , providing and supplying of dc led lamp set 3w 5w 10w set of 3 , providing and supplying of dc pump 24 v , providing and supplying of pwm controller , providing and supplying of mppt charge controller , providing and supplying of inverter with battery 1 kva with 12 v battery input 12 volt dc output 220 volt ac
Tender For special repair of low voltage panels and feeder pillars installed in various locations and special repair of deteriorated lightningprotectionsystem of building in maintenance ofora and depot at maintenance of (mb) ghatkopar under ge (nw) bhandup
Tender For survey investigation, design, supply, installation, testing and commissioning of tank filling scheme consisting of construction of intake channel, forebay, jack well cum pump house, power supply including terminal bay, transmission line, electrical substation, rising main, distribution network, delivery chamber, gravity main network, various types of valves, receiving chambers, staff quarters, surge protectionsystem for filling of 22 tanks in kambadal hosur and surrounding villages by lifting 0.19 tmc of water from bhadra river near gonibeedu village of bhadravathi taluk, shimoga district including operation and maintenance for a period of 5 years after successful completion of work for kambadal hosur tank filling scheme on turn-key basis
Tender For corrigendum : supply of high availability single section digital axle counter (hassdac) system complete as per rdso specification rdso/spn/ 177/2012 ver. 3.0 or latest. the system shall consist of the following: a)track side high availability digital axle counter unit - 2 nos. b) axle detectors (each set consists of web mounting type 2 nos tx coils and 2 numbers rx coils) - 2 sets c) vital relay box - 2 numbers. each box shall be wired with following relays. d) vital relay qna1k, 24v, 6f/6b - 2 nos. e) reset relay qna1k, 24v, 6f/6b - 1 no. f) preparatory pr relay qnn1, 24v, 6f/2b (dual) - 1 no. g) clamp with deflector plates and hardware - 4 nos. h) reset box model no.259a - 2 nos i) surge voltage protection device mounted on din 35 rail - 2 nos.