Tender For corrigendum : supply of liquefiedpetroleumgas, type : commercial butane- propane mixture,confirming to is:4576-1999 (second revision) with amendment no 1 of may 2003 (reaffirmed 2009) edition 3.1 (2003-05) in 19 kgs cylinders. as per specn. cylinders. [ warranty period: 30 months after the date of delivery ]
Tender For quotation for stationery items , cartridge refilling , computer and printer spares , banner printing , streetlight items supply , pesticide medicines and bleaching powder , vehicle hiting , xerox work , tent and mic set , etc.
Tender For work contract for “day to day maintenance, shifting of fire extinguishers plant to fire station, cleaning, fitting, refilling of fire extinguishers, testing and fitting of valves of firefighting system of dspm tps korba eastâ€.
Tender For out sourcing comprehensive maintenance of civil, electrical operations relating to day to day maintenance, special repair and house keeping etc of custom and central excise colony including water supply pump set fire fighting, lift diesel generator set and horticulture work, vibhuti khand gomti nagar (up) (sh:- refilling of fire extinguishers)
Tender For the scope of this contract shall include servicing, painting, certification, labeling, refilling and periodical maintenance of co2, abc and mechanical foam type of fire extinguishers for a period of 2 years at nagjhari power house and ambikanagar office complex covering all associated works and components required for successful completion of the work.
Tender For following works shall be carried out quarterly during the contract period for the two identical sets of co2 flooding system at mghe power house. the one set of system for carting to the units-1,2,3&4 and the second set of system for carting to units-5,6,7&8. i)cleaning of heat detector externaly with dry cloth ii)ensure working condition of heat detectors iii)cleaning of smoke detector externaly with dry cloth iv)ensure working condition of smoke detectors v)simulate heat and smoke detector simultaneously and check for cross zone vi)checking for leakage in pilot cylinder vii)checking the weight of co2 pilot cylindersviii)check the condition of co2 pilot hose ix)check the condition of co2 discharge hose x)inspect pressure switch and check for its functioning xi)inspect maual call points and check for its functioning xii)inspect abort switch and check for its functioning xiii)inspection of online weigh monitor and check for its functioning xiv)inspect hooter with strobe and check for its functioning xv)checking for healthiness of the battery xvi)checking the condition for slave nrv xviichecking the condition for master nrv xviii)checking of solenoids. xix)refilling of co2 cylinder and pressure testing 45 kg capacity and 4.5kg capacity (in case release of co2 gas during generator fire incidents) xx)any other work connected with the system not explicitly mentioned shall also be carried out for safe and proper operation of the system. xxi)conducting the demo of operation of the co2 flooding system twice (once in 2 quarter) during the annual maintenance contract period for kpcl staff.
Tender For corrigendum : work of annual contract for supply / refilling of toner in laser/inject printers including all consumable parts-repairing and replacement at all s.dn ,lab,tru, store under city-1 division bhavnagar