Get complete information related to latest Load Balancer Repair Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Load Balancer Repair Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Load Balancer Repair Tenders.
Tender For corrigendum : supply of deluge system equipment for msb unit for nrep - a. deluge water spray systems (mvws system + water curtain system + hvws system)cs deluge valve with dry pilot trim & electric release trim, horizontal inlet & horizontal outlet, without skid, ul/fm approved, complete with dry pilot trim with test, alarm & drain devices, local deluge valve control station (dvlcs) (1 no. per dv), pressure transmitters (02 nos per dv.), 3/3 way sil2 certified intrinsically safe solenoid valve-24v dc (1 no. per dv), pressure gauges (03 nos. per dv), air filetr regulator (afr)(1 no. per dv), air vessel of adequate capacity (1 no. per dv), etc. in compliance with the scheme shown in attached "technical data sheets for fire fighting & safety equipment (tk-1p21a-sa-dat-0001)".the deluge valves shall be supplied with the trim and associated instruments duly assemblied with the deluge valve and with suitable packaging to avoid damage during transportation. the upstream strainer, block valves and by-pass valve including the pipes connecting to these items are not in bidders scope of supply.all items shall be suitable and certified for zone 1,iic,t3 area classification. all electrical and instruments shall be certified for intrinsically safe (ex-ia) and solenoid valve shall be certified to explosion proof (ex-d). all instruments and enclosures (junction boxes/ cabinets/panels/ accessories) in field shall be dust proof and weather proof with ip-67., 200 mm nb, 150 mm nb, 100 mm nb, 80 mm nb, mvw spray nozzle with 1/2" mnpt end connection, moc - stainless steel, ul / fm listed, (with inbuilt strainer): size 15 nb, mvw spray nozzle with 1/2" mnpt end connection, k factor-18, spray angle 120 , moc - stainless steel with corrosion resistant coating, ul listed., mvw spray nozzle with 1/2" mnpt end connection, k factor-18, spray angle 110 , moc - stainless steel with corrosion resistant coating, ul listed., mvw spray nozzle with 1/2" mnpt end connection, k factor-18, spray angle 90 , moc - stainless steel with corrosion resistant coating, ul listed., mvw spray nozzle with 1/2" mnpt end connection, k factor-22, spray angle 110 , moc - stainless steel with corrosion resistant coating, ul listed., mvw spray nozzle with 1/2" mnpt end connection, k factor-22, spray angle 90 , moc - stainless steel with corrosion resistant coating, ul listed., mvw spray nozzle with 1/2" mnpt end connection, k factor-26, spray angle 120 , moc - stainless steel with corrosion resistant coating, ul listed., mvw spray nozzle with 1/2" mnpt end connection, k factor-26, spray angle 90 , moc - stainless steel with corrosion resistant coating, ul listed., mvw spray nozzle with 1/2" mnpt end connection, k factor-30, spray angle 120 , moc - stainless steel with corrosion resistant coating, ul listed., mvw spray nozzle with 1/2" mnpt end connection, k factor-30, spray angle 110 , moc - stainless steel with corrosion resistant coating, ul listed., mvw spray nozzle with 1/2" mnpt end connection, k factor-30, spray angle 90 , moc - stainless steel with corrosion resistant coating, ul listed., mvw spray nozzle with 1/2" mnpt end connection, k factor-35, spray angle 110 , moc - stainless steel with corrosion resistant coating, ul listed., mvw spray nozzle with 1/2" mnpt end connection, k factor-35, spray angle 90 , moc - stainless steel with corrosion resistant coating, ul listed., mvw spray nozzle with 1/2" mnpt end connection, k factor-41, spray angle 90 , moc - stainless steel with corrosion resistant coating, ul listed., mvw spray nozzle with 1/2" mnpt end connection, k factor-51, spray angle 110 , moc - stainless steel with corrosion resistant coating, ul listed., mvw spray nozzle with 1/2" mnpt end connection, k factor-51, spray angle 90 , moc - stainless steel with corrosion resistant coating, ul listed., mvw spray nozzle with 1/2" mnpt end connection, k factor-79, spray angle 90 , moc - stainless steel with corrosion resistant coating, ul listed., quartzo
Tender For tender for supply of soil investigation - mobalisation of necessary eqpt and man power to the project site and dismantling of the same of completion of field work from the site , provision of two bore hole of 150 mm dia in any type of soil upto max 10 mtr or upto refusal n 100 whichever meet first conducting standard penetration test as per is 2131 1981 reaffirmed 2016 test shall be made at not more than 1 50 mtr interval or on change of strata whichever is less , conducting following lab test on bore collected soil sample i direct triaxial shear test ii grain distribution curves & pattern in bore holes iii bulk density iv natural moisture content v dry density vi water table vii specific gravity viii atterberg limit ix hydrometer analysis x liquid & plastic limit xi swelling index , collection of lab test data calculation of gross and net safe bearing capacity and preparation of report on minimum 80 gsm a4 size white paper duly spiral bound in quintuplet duly vetted by any iit nit vetting shall not be in the personal capacity of the professor for foundation report shall recommend type of foundation and sizes at different depths below ngl including size gross and net safe bearing capacity , i photographic record of geo exploration as well as testing shall also part of the report ii recommendation as regards possibility of liquefaction of soil in case of saturated or partially saturated loose uncompacted sandy soil iii swelling index and swelling pressure in respect of black cotton soil and its depth layer if any iv depth of gr water table gwt in peak mansoon lowest and peak summer highest after correlation of result with seasonal of water table in the station v recommendation for filling under floors vi rl of ground level foundation level with ref to a bm should invariably be mentioned in the soil investigation report
Tender For work for rectification of defect in existing alstom make scada system and configuration of gateway for data transmission to sldc and sub sldc at 132 kv sub station sarila, hamirpur under etd hamirpur.
Tender For work for rectification of defect in existing alstom make scada system and configuration of gateway for data transmission to sldc and sub sldc at 132 kv sub station patara, hamirpur under etd hamirpur.
Tender For work for integration of new 33 kv bay and rectification of deffect in existing siemens make scada system and configuration of gateway for data transmission to sldc and sub sldc at 132 kv sub station pailani, under etd banda.
Tender For supply of 1) auto-pointing reflector-less electronic total station, auto-pointing of 1000 mtrs, colourlcd touch screen dual face display, 0.5 second least count and 1 second accuracy, capable of measuring appr oximate 1000 mtrs in reflector-less mode and approximate 6 kms under good weather conditions with singl e prism, with an accuracy of (1 mm + 2 ppm xd) in prism mode, internal memory of 1 gb, with data interfa ce such as usb flash memory for pen drive and usb type mini b port, guide light unit to assist in quick set ting out, graphical display of surveyed points, comes along with the following accessories: (i) main unit. (ii) rechargeable batteries x2. (iii) quick charger with power cable, stylus, lens hood, lens cap, (iv) tool kit o perations manual and carrying case. (v) pen drive. (vi) companyoriginal calibration certificate & warranty card. 2) wooden telescopic tripod. 3) single range pole assembly, consisting of prism, single tilting mount with co-axial target, telescopic range pole, range pole level and all in soft carrying case. 4) range pole trip od for prism. model-ix-601 of make sokkia or similar. [ warranty period: 24 months after the date of deliv ery ]
Tender For upgradation of substation control and monitoring system with supervisory control and data acquisition with associated accessories for different 11kv and 3.3 kv circuit breakers at karo sub station
Tender For repair maintenance of external services i/c sub-station & dg sets installed at north block, new delhi. (sh: providing services for preparing/ editing of files and entry of data etc. and providing staff for office assistant.)
Tender For contingencies of the works- 1.maintenance of 2 nos. lifts, sub-station, fire alarm system, diesel generator set etc. at old ag office building at bhubaneswar, odisha during 2025-26. 2. maintenance of 2 nos. lifts, sub-station, fire alarm system, fire fighting system, vrf system, diesel generator set etc. at new ag office building at bhubaneswar, odisha during 2025-26. 3. maintenance of 62.5 kva diesel generator set, 4 nos. 500 kva transformer, sub-station of new ag colony, bhubaneswar during 2025-26. 4. maintenance of 62.5 kva diesel generator set, sub-station of old ag colony at bhubaneswar during 2025-26. sh-providing service of data entry operator.
Tender For corrigendum : procurement of motion platform small capable to carry car rear target adult dummy and adult bicycle dummy control station for motion platform small communication system in between rtk based data logger and motion platform small