Tender For supply and delivery of 75 hp pump motor and panel board and starter at adhi nagar sewerage pumping station at zone-5 east tambaram area in tambaram city municipal corporation
Tender For corrigendum : supply of electrical ee1 d d - 2 , scr triggering circuits experiment board and trainer kit 1 , scr triggering circuits experiment board and trainer kit 2 , set of induction motor coupled dc shunt generator 1 , set of induction motor coupled dc shunt generator 2 , simulation panel for differential protection of transformer1 , simulation panel for differential protection of transformer2 , simulation panel for differential protection of transformer3 , simulation panel for differential protection of transformer4 , simulation panel for differential protection of transformer5 , simulation panel for differential protection of transformer6 , simulation panel for differential protection of transformer7 , simulation panel for differential protection of transformer8 , simulation panel for differential protection of transformer9 , single phase 1 hp induction motor 1 , single phase 1 hp induction motor 2 , single phase auto transformer 1 , single phase auto transformer 2 , single phase auto transformer 3 , single phase auto transformer 4 , single phase auto transformer 5 , single phase auto transformer 6 , single phase auto transformer 7 , single phase auto transformer 8 , single phase auto transformer 9 , single phase power factor meter 1 , single phase power factor meter 2 , single phase power factor meter 3 , single phase power factor meter 4 , single phase transformer 1 kva 1 , single phase transformer 1 kva 2 , single phase transformer 1 kva 3 , single phase transformer 1 kva 4 , single phase universal motor 1 , single phase universal motor 2 , switchgear testing kit 1 , switchgear testing kit 2 , switchgear testing kit 3 , three phase auto transformer 1 , three phase auto transformer 2 , three phase auto transformer 3 , three phase auto transformer 4 , three phase auto transformer 5 , three phase auto transformer 6 , three phase induction motor protection simulation unit 1 , three phase induction motor protection simulation unit 2 , three phase induction motor protection simulation unit 3 , three phase induction motor protection simulation unit 4 , three phase transformer 5kva 1 , three phase transformer 5kva 2 , three phase transformer 5kva 3 , three phase transformer 5kva 4 , three phase transformer 5kva 5 , three phase transformer 5kva 6 , three point starter for dc motor 230 volts, 10 amps 1 , three point starter for dc motor 230 volts, 10 amps 2 , transformer workbench 1 , transformer workbench 2 , transformer workbench 310 mz function generator 1, 10 mz function generator 2, 10 mz function generator 3, 10 mz function generator 4, 10 mz function generator 5, 10 mz function generator 6, 10 mz function generator 7, 10 mz function generator 8, 5 mhz function generator counter with power supply 1, 5 mhz function generator counter with power supply 2, 5 mhz function generator counter with power supply 3, 5 mhz function generator counter with power supply 4, potential transformer 1, potential transformer 2, simulation panel for differential protection of transformer1, simulation panel for differential protection of transformer2, simulation panel for differential protection of transformer3, simulation panel for differential protection of transformer4, simulation panel for differential protection of transformer5, simulation panel for differential protection of transformer6, simulation panel for differential protection of transformer7, simulation panel for differential protection of transformer8, simulation panel for differential protection of transformer9, single phase auto transformer 1, single phase auto transformer 2, single phase auto transformer 3, single phase auto transformer 4, single phase auto transformer 5, single phase auto transformer 6, single phase auto transformer 7, single phase auto transformer 8, single phase auto transformer 9, //bid details2 / 90
Tender For construction of 1 no. 360 men barrack (g plus 7), 1 no. pump house, 1 no. substation building including internal water supply sanitary installation, drainage development work and e&m works for crpf at new town, rajarhat, kolkata.(sh : phase-i providing of monoblock motor pumping set including starter panel, valves, gi pipes etc. for water supply system.)
Tender For corrigendum : providing materials for watersupply items to kattalagere gp davanagere dist. - mains wire //ana gp, panel board items //ana gp, cable 4mm //ana gp, pump 18 stage //ana gp, pump 16 stage //ana gp, pump 14 stage //ana gp, pump 12 stage //ana gp, moter 10hp //ana gp, moter 7.5hp //ana gp, moter 6hp //ana gp, bar casing up //gp, bar casing //gp, steeg box //gp, panel bourd //gp, nrv 2 g a //gp, puc 63 m m threeded elbow //gp, puc cap 25 m m //gp, puc cap 75 m m //gp, puc cap 63 m m //gp, motor 6 h p 10 stage //gp, motar cail //gp, elbow 1/2 g a //gp, caller 1/2 g a //gp, nipple 1/2 g a 2 feet //gp, nipple 1/2 g a 1 feet //gp, elbow 3/4 g a //gp, caller 3/4 g a //gp, nipple 3/4 g a 2 feet //gp, nipple 3/4 g a1 feet //gp, electrical tape//gp, motor 7.5 15 stage //gp, motor 7.5 12 stage//gp, realy //gp, volto meter //gp, hamse meter //gp, starter //gp, praventer //gp, auto stater //gp, pipe 2 g a //gp, caller 2 g a //gp, nipple 2 g a feet //gp, bend 2 g a //gp, cabel 4 sq //gp, xcet blade //gp, selvent //gp, puc tee 25 mm //gp, puc tee 75 mm //gp, puc tee 63 mm //gp, puc elbow 75 mm //gp, puc elbow 63 mm //gp, puc elbow 25 mm //gp, puc caller 75 mm //gp, puc caller 63 mm //gp, puc caller 25 mm //gp, repair coupler 110 mm //gp, repair coupler 90 mm//gp, repair coupler 75 mm //gp, repair coupler 63 mm //gp, puc ballwall 75 mm //gp, puc ballwall 63 mm //gp, puc ballwall 20 mm //gp, puc ballwall 25 mm //gp, puc pipe 110 mm //gp, puc pipe 90 mm //gp, puc pipe 75 mm //gp, puc pipe 63 mm //gp, puc pipe 50 mm //gp, puc pipe 40 mm //gp, puc pipe 32 mm //gp, puc pipe 25 mm //gp, puc pipe 20 mm //gp
Tender For rewinding of 335hp motor no. 3 and provision and repair of 650 amps contactor for fcma starter no. 3, repair of fcma soft starter no. 2 and standby starter and repair of apfcr panel at pnr palya pump house in city corporation limit
Tender For corrigendum : ridf xxviii - lift irrigation projects in various padashekharams of wayanad district- procurement of submersible pumpsets, fittings, accessories, and related electrical works - procurement, installation, erection, testing, and commissioning of pumpsets and allied works at punchavayal, manikkuni, kolembetta, valiyavattam, and padiyeri pumphouses. - procurement, installation, erection, testing, and commissioning of pumpsets and allied works at punchavayal, manikkuni, kolembetta, valiyavattam, and padiyeri pumphouses., supply, installation, erection, testing, commissioning and fitting charges for all accessories of horizontally mounted submerged centrifugal non clog pump set of compact unitary mono-block submerged single/multi stage,volute type casing with suitable radial type impellers on common shaft for pump and motor ,anti friction bearing with life time greasing, protection features with sensors to monitor temperature,mechanical seal leakage ,etc.(the pump should be confirming to his/is standards).the moc of pump,casing-cast iron,impeller -ss cf8m,shaft-ss-316,suction strainer -ss and other as per is standard.the motor should be suitable for 3 phase,415v /-10%,50hz /5%,ac supply submersible motor having class f /h insulation, air filled and ip-68protection confirming to is 325 or latest standards suitable for day night operation.the pump discharge capacity of 230 cubic metre /hour against duty point head of 42 mtrs, working head range 18 - 47m, discharge range 136 - 57 lps ,speed 1450rpm(n) or nearer ,with 10meters of copper power cable and control cable, railing arrangement. the pump should be painted with three coats of suitable anti corrosive paint over priming coat. the electrical works for the pumpset should be completed as per kseb rules and regulations and the contractor is responsible for arranging premissions and certificates from the electrical inspectorate. the suction side of the pumpset should be provided with an additional iron grill for preventing foreign particles inside the inlet side of the pump casing., supply and erection of 60hp auto transformer starter (ats) with suitable incommer and contactors including 24 kvar capacitor with required indications ,metering and protections for single phasing ,overload, pump monitoring unit to protect from ingress, high temperature level etc enclosed in a closed panel board, supply and laying additional termination cable of 1.1kv 3.5 core 95sqmm aluminium conductor xlpe insulated ;steel armoured ug cable as per relevant is 7098 with support for cable, supply, installation, erection, testing, commissioning and fitting charges for all accessories of horizontzlly mounted submerged centrifugal non clog pump set of compact unitary mono-block submerged single/multi stage,volute type casing with suitable radial type impellers on common shaft for pump and motor ,anti friction bearing with life time greasing, protection features with sensors to monitor temperature,mechanical seal leakage ,etc.(the pump should be confirming to his/is standards).the moc of pump,casing-cast iron,impeller -ss cf8m,shaft-ss-316,suction strainer -ss and other as per is standard.the motor should be suitable for 3 phase,415v /-10%,50hz /5%,ac supply submersible motor having class f /h insulation, air filled and ip-68protection confirming to is 325 or latest standards suitable for day nightoperation.the pump discharge capacity of 188 cubic metre /hour against duty point head of 35 mtrs,working head range 16 - 42m, discharge range 102 - 42 lps ,speed 1450 rpm(n) or nearer ,with 10meters of copper power cable and control cable,railing arrangement. the pump should be painted with three coats of suitable anti corrosive paint over priming coat. the electrical works for the pumpset should be completed as per kseb rules and regulations and the contractor is responsible for arranging premissions and certificates from the electrical inspectorate. the suction side of the pumpset should be provided wi
Tender For supply of prabhu industrial make auto transformer starter d d - isolator 630a 6600 v on off earth part no ht100c , vaccum contactor 400 amp 6600 v grade part no ht200 , diode by255 for vacuum contactor part no ht200c , vaccum contactor rectifier bridge part no ht201 , bottle for vacuum contactor 400amps 6600 v part no ht202 , vacuum contactor closing coil 110 vdc part no ht203 , vacuum contactor holding coil 110 vdc part no ht204 , pt 50 va pri 110v sec 0 to 8 to 12 v part no ht206 a , auxiliary contactor 3no 1nc 110 v part no ht208 , ht control fuse 6600 v 2amp part no ht400 , resin cast moulded cbct 6600 v part no ht500a , epoxy moulded 2 core ct ratio125 200 to 5 5 part no ht600c , earth leakage realy 30 ma to 3a with time delay part no ht800a , copper terminal bar for outgoing terminal part no ht701 a , ct operated motor protection relay ct sec 5a part no ht900e , ammeter 96 sq mm, part no ht1000a , ammeter selector switch part no 1001 , voltmeter 96 sq mm part no ht1100 a , voltmeter selector switch part no ht1101 , lamp holder with lamp on off and trip part no ht1400 , push button with element for start and stop part no ht1300 , power hrc fuse part no ht1500 , timer electronics 3 sec to 3 min on delay part no ht2004a , intrinsically safe pilot panel complete part no ht3000 , auto transformer oil cooled copper wound part no tr1000kw , copper bus bar 400amps 6600 v part no ht101a , realy overvoltage and under voltage realy part no ht4004 ) /bid number: gem/2026/b/7092913 * /dated: 19-01-2026 & & / bid document1 / 23
Tender For transportation laying and charging of armored cable and 02 nos pump motor and starter from surface to ug or old panel no 12ls 17ls to cm panel 27d and panel 27r dep distt 4a seam at haldibari ug mine