Web Analytics Made Easy - StatCounter

Lt Bushing Tenders

Get complete information related to latest Lt Bushing Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Lt Bushing Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Lt Bushing Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :40242232 Due date: 16 May, 202516 May, 2025 NA
Tender For supply of supply of the hydraulic power pack with chiller unit , installation & commissioning of the hydraulic power pack with chiller unit

corporations/Associations/Others

CTN :40206381 Due date: 08 May, 202508 May, 2025 8.40 Lacs
Tender For for the work of replacement of old and damaged lt bushing rod including oil seal/gaskets etc. (250 to 1000 kva transformer) under 11 kv and lt line- north, meerut.

corporations/Associations/Others

CTN :40208625 Due date: 19 May, 202519 May, 2025 NA
Tender For supply of lt bushing brass rod 12 mm dia

CTN :40156713 Due date: 13 May, 202513 May, 2025 233.82 Crore
Tender For purchase of 16 kva, 3 phase aluminium wound energy efficient level-1 (star-1) completely self protected (csp) distribution transformers with provision of lt bushing box

corporations/Associations/Others

CTN :38469235 Due date: 02 May, 202502 May, 2025 102.18 Crore
Tender For corrigendum : supply of 40 kva, 11/0.433 kv, aluminium wound eel-1 (is:1180-1:20144 amendment) star-1 rating completely self protected (csp) distribution transformers with having provision of lt bushing box against tn2025

corporations/Associations/Others

CTN :38469234 Due date: 02 May, 202502 May, 2025 74.02 Crore
Tender For corrigendum : supply of 25 kva, 11/0.433 kv, aluminium wound eel-1 (is:1180-1:20144 amendment) star-1 rating completely self protected (csp) distribution transformers with having provision of lt bushing box against tn2026

Central Government/Public Sector

CTN :39814316 Due date: 06 May, 202506 May, 2025 NA
Tender For corrigendum : supply of hydraulic power supply unit bhel mcode w90311400299 , main con trol fluid pump along with motor & coupling bhel mcode w99311400483 , bearings of main cfp motor ie3 bhel mcode w99318146434 , cfp motor for main hpsu bhel mcode w99318146418 , motor for circulation pump for main hpsu ie3 bhel mcode w99318146426 , pressure transmitter for main hpsu bhel mcode w99318146205 , level transmitter for main hpsu bhel mcode w99318146191 , pressure switch for main hpsu bhel mcode w99318146140 , differential pressure switch type-1 for main hpsu bhel mcode w99318146159 , differential pressure switch type-2 for main hpsu bhel mcode w99318146167 , differential pressure switch type-3 for main hpsu bhel mcode ww99318146175 , proximity switch for main hpsu bhel mcode w99318146230 , rtd for main hpsu bhel mcode w99318146213 , pressure gauge type-1 for main hpsu bhel mcode w99318146094 , pressure gauge type-2 for main hpsu bhel mcode w99318146108 , pressure gauge type-3 for main hpsu bhel mcode w99318146116 , pressure gauge type-4 for main hpsu bhel mcode w99318146124 , permanday charges for training supervision during erection and commissioning , per visit charges for training supervision during erection and commissioning

corporations/Associations/Others

CTN :40126145 Due date: 05 May, 202505 May, 2025 2.62 Lacs
Tender For 22/2025-26 purchase of laqshya instruments - purchase of instruments ( laqshay), radiant warmer- technical specification of radiant warmer with baby bassinet a radiant warmer is used to keep the patient s core temperature stable at 37 o c. it should be microprocessor controlled radiant warmer with manual and servo options. it should have facility to display both skin and air (ambient) temperature separately.. it should have audiovisual alarm facility for overheating beyond set temperature range. it should have alarm facility for patient temperature less than or greater than the required temperature i.e. above or below the set range. it should rotate and swivel in different direction, so as to allow taking x-ray. the light should be dazzle free. it should have alarm for power failure. it should have alarm for heater failure and auto cut off for high temp. it should have alarm for probe failure. it should have time out alarm in manual mode. it should have facility to auto reset the system in case of hang up caused by power fluctuation. it should have manual setting for high and low alarm setting. in servo mode, the heater output should be controlled to maintain the baby at the required set temperature. in manual mode, the heater output should be directly controlled by a setting on the front panel should have a facility to lock the keyboard to avoid unwanted user. the desired temperature range from 25 to 40 degree c. the resolution should be 0.1 degree c halogen based observation light should be provided for observing the baby. it should be mounted on a pole with sturdy base with lockable castors power supply: power input to be 220-240 vac, 50hz fitted with indian plug. certificate of calibration and inspection from the factory. warranty: comprehensive warranty for 5 years after warranty documentation: user, technical, maintenance manuals to be supplied ce, iso certified , fetal doppler - technical specification of fetal doppler should be compact, table type and light weight. large lcd display for display of fetal heart rate. back light for better visibility display signal quality, low battery, etc., high sensitivity doppler probe of frequency 2.0 mhz ultra sound intensity 10mw/cm2. built-in speaker with output not less than 1.0w should work on rechargeable batteries with minimum battery time of 300minutes. battery charger and spare set of batteries aa type to be supplied. volume control facility and audio output for ear phone should be available. heart rate range should be from 50 to 240 b pm with accuracy of + /-2% should be water proof body. should have facility for fhr data transfer to pc. doppler probe should be light weight with holder facility when not in use. should be supplied with carrying case. machine should be iso mark, baby digital thermometer - technical specification of baby digital thermometer range 0.1 to 1000 degree centigrade measurement mode- min, max, average, differential, dual temperaturereading measurement unit- degree centigrade, degree fahrenheit,kelvin temperature probe with connecting cable relative humidity10 to 90% rh non-condensing ip rating- ip 40 g) probe response time 2-3 seconds it should be who & unicef standards, delivery trolley/patient stretcher trolley- technical specification of patient stretcher trolley overall size: 1905mm l x 710mm w x 660mm to 910 mm h. stretcher dimension 1830 mm l x 555 mm w. two section top. height adjusted by foot operated maintenance free hydraulic pump. height adjustment shall be obtained by hydraulically operated mono block type linear actuator pump foot operated actuation having stroke of 140 +/- 5 mm, push force 10 kn at 270 bars, number of complete pump stroke 22 to 24 for full stroke length x-ray permeable removable stretcher, backrest raised on ratchet. quick trendelenburg as well as reverse trendelenburg positions shall be provided with easily accessible operating handle provided with two gas springs for easy action. s.s. saline rod with 12 mm dia s.s

corporations/Associations/Others

CTN :40126147 Due date: 05 May, 202505 May, 2025 2.62 Lacs
Tender For 22/2025-26 purchase of laqshya instruments - purchase of instruments ( laqshay), radiant warmer- technical specification of radiant warmer with baby bassinet a radiant warmer is used to keep the patient s core temperature stable at 37 o c. it should be microprocessor controlled radiant warmer with manual and servo options. it should have facility to display both skin and air (ambient) temperature separately.. it should have audiovisual alarm facility for overheating beyond set temperature range. it should have alarm facility for patient temperature less than or greater than the required temperature i.e. above or below the set range. it should rotate and swivel in different direction, so as to allow taking x-ray. the light should be dazzle free. it should have alarm for power failure. it should have alarm for heater failure and auto cut off for high temp. it should have alarm for probe failure. it should have time out alarm in manual mode. it should have facility to auto reset the system in case of hang up caused by power fluctuation. it should have manual setting for high and low alarm setting. in servo mode, the heater output should be controlled to maintain the baby at the required set temperature. in manual mode, the heater output should be directly controlled by a setting on the front panel should have a facility to lock the keyboard to avoid unwanted user. the desired temperature range from 25 to 40 degree c. the resolution should be 0.1 degree c halogen based observation light should be provided for observing the baby. it should be mounted on a pole with sturdy base with lockable castors power supply: power input to be 220-240 vac, 50hz fitted with indian plug. certificate of calibration and inspection from the factory. warranty: comprehensive warranty for 5 years after warranty documentation: user, technical, maintenance manuals to be supplied ce, iso certified , fetal doppler - technical specification of fetal doppler should be compact, table type and light weight. large lcd display for display of fetal heart rate. back light for better visibility display signal quality, low battery, etc., high sensitivity doppler probe of frequency 2.0 mhz ultra sound intensity 10mw/cm2. built-in speaker with output not less than 1.0w should work on rechargeable batteries with minimum battery time of 300minutes. battery charger and spare set of batteries aa type to be supplied. volume control facility and audio output for ear phone should be available. heart rate range should be from 50 to 240 b pm with accuracy of + /-2% should be water proof body. should have facility for fhr data transfer to pc. doppler probe should be light weight with holder facility when not in use. should be supplied with carrying case. machine should be iso mark, baby digital thermometer - technical specification of baby digital thermometer range 0.1 to 1000 degree centigrade measurement mode- min, max, average, differential, dual temperaturereading measurement unit- degree centigrade, degree fahrenheit,kelvin temperature probe with connecting cable relative humidity10 to 90% rh non-condensing ip rating- ip 40 g) probe response time 2-3 seconds it should be who & unicef standards, delivery trolley/patient stretcher trolley- technical specification of patient stretcher trolley overall size: 1905mm l x 710mm w x 660mm to 910 mm h. stretcher dimension 1830 mm l x 555 mm w. two section top. height adjusted by foot operated maintenance free hydraulic pump. height adjustment shall be obtained by hydraulically operated mono block type linear actuator pump foot operated actuation having stroke of 140 +/- 5 mm, push force 10 kn at 270 bars, number of complete pump stroke 22 to 24 for full stroke length x-ray permeable removable stretcher, backrest raised on ratchet. quick trendelenburg as well as reverse trendelenburg positions shall be provided with easily accessible operating handle provided with two gas springs for easy action. s.s. saline rod with 12 mm dia s.s

CTN :39498866 Due date: 28 Apr, 202528 Apr, 2025 NA
Tender For bid to ras supply of hydraulic power unit (hpu)
 Loading, Please wait...

Connect us via What's Up