Get complete information related to latest Lt Rod Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Lt Rod Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Lt Rod Tenders.
Tender For corrigendum : providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - industry unit; electrical system or installation, design, supply, installation and commissioning of diffrential protection system; service provider
Tender For tender for supply of 2 mp network ptz camera 45x zoom ir range 300 mtr , 2 mp network bullet camera verifocal zoom ir range 60 mtr , prefabricated gi pole of 30 feet length with stair provision with cemented work , pvc pipe with bends for safety of cameras wiring , weather proof outdoor boxes for cameras accessories with locks , power surge protector for cameras accessories , 4 port gigabit ethernet switch with poe with 2 uplinks , ethernet media converter gigabit , sc to sc fiber patch cable single mode , ethernet utp patch cord 10 mtr length , ofc fiber cable 6 fiber single mode un-armouredwith laying , outdoor cat 6 utp cable , power cable 2 core 10 sqmm armoured , fiber joint box , support wire for fixing of ofc and power cable , necessaries hardware and accessories for cameras , necessaries hardware and accessories for electrical , power backup inverter for cameras and accessories , power backup tubular battery for cameras and accessories , power board for inverter connection , 3 pin top for backup connection wiring , outdoor weather proof protection unit for ups , installations of power backup solution , boom barrier 6 meter with 2 way controller , visitor/vehicle management software , access management biometric devices , access management rfid reader , access management controller card , rfid tags , vehicle windshield tags , visitor management system all in one , necessaries hardware and accessories for visitor management poles boxes cablling etc , network video recorder 64 channel with smart features , network video recorder 16 channel with smart features , hard disk 4 tb for surveillance recording , display unit 65 inch for monitoring with hdmi cable 15 meter , display unit 43 inch for monitoring with hdmi cable 15 meter , suitable networking 6 u racks at sub sector control rooms , suitable networking 22 u rack floor mounted at main control rooms , installations transportation and commissioning of the above project with 1 year warranty period including of other required accessories , hand tool kit with multiple tolls as required for repair cameras , crimping tool , splicing machine with all accessories
Tender For corrigendum : survey, design, supply, installation, testing and commissioning of trackside kavach (indian railway automatic train protection system) equipments at stations/lc gates/ibs locations including optical fiber cable works, erection of towers and associated civil/track/electrical works required for kavach in itarsi-manikpur, mahdeiya-bina malkheri-mahadeokheri, entire katni complex, bina malkheri-agasod, satna-rewa, kaima-sagma, bansapahar-ohan section of jabalpur division of west central railway.
Tender For supply, installation, testing and commissioning of primary protection class b or type 2 supply and installation of surge protection device , supply, installation, testing and commissioning of second stage protection class c or type 3 supply and installation , supply, installation, testing and commissioning of earthing with copper earth , supply, installation, testing and commissioning of 25 mm x 3 mm copper strip , supply, installation, testing and commissioning of 4mm dia copper wire with clamps or tie , supply, installation, testing and commissioning of conventional vertical air terminal lightening arrestor, made of 1 inch dia 5 feet length , supply, installation, testing and commissioning of elevation pole made of gi material , supply, installation, testing and commissioning of elevation pole made of gi , supply, installation, testing and commissioning of 50 mmx 3 meters length material , supplying and laying of heavy duty pvc pipes for electrical applications, 100mm diameter, standards outlined , supplying and laying of electrical hose pipe in a 40mm diameter, require it to be gi pipe , supply, installation, testing and commissioning of raceway with l and t junctinon 6 inch x 10 feet x18 gnuge of perforated type cable , supply, installation, testing and commissioning of perforated cable trays at with l and t junctinon 6 inch x 10 feet x18 gnuge made out of prefabricated galvanized sheet steel , supply, installation, testing and commissioning of extension board , sitc of providing joints by using brazing technique on 25 mm x 3 mm copper or gi strip on surface or in recess for connections to another copper or gi earth , supply, installation, testing and commissioning of earthing with copper earth plate , supply, installation, testing and commissioning of gi pipe earthing , supplying and laying 25 mm x 3 mm copper strip , sitc of 5 kg abc or co2 type fire extinguishers , design, manufacturing, supply, installation, testing and commissioning of environmental friendly aerosol based fire suppression system , supply, installation, testing and commissioning of conventional agent release control panel with battery back up for 30 minutes in alarm condition , supply, installation, testing and commissioning of conventional type en listed or equivalent indian standard ip based optical smoke detectors , supply, installation, testing and commissioning of conventional type en listed or equivalent indian standard ip based heat combination detectors , supply, installation, testing and commissioning of en listed or equivalent indian standard ip based manual release switch , supply, installation, testing and commissioning of en listed or equivalent indian standard ip based manual abort switch , supply, installation, testing and commissioning of en listed or equivalent indian standard op based manual call point, , supply, installation, testing and commissioning of en listed or equivalent indian standard ip based conventional sounder cum strobe , supply, installation, testing and commissioning of gas discharge identification signage , supply, installation, testing and commissioning of addressable ip based multi photo electric or optical smoke detector or fire sensor , supply, installation, testing and commissioning of auto dialer unit , supply, installation, testing and commissioning of ip based addressable manual call point , supply, installation, testing and commissioning of ip based addressable horn cum strobe , supply, installation, testing and commissioning of fire alarm armoured cable , supply, installation, testing and commissioning of response indicator on surface or recess ms box , supply, installation, testing and commissioning of supporting tube for hvi long conductor , supply, installation, testing and commissioning of elevation pole made of gi material having isi marking , supply, installation, testing and commissioning of fixing clamp with tensioning strap, for fixing combi supporting tubes , supply, installation, testing and comm
Tender For repair and upgradation of fire detection system and repairing existing entire fire protection system, supply and delivery of hose pipe and hose real, all electrical shaft closed by fire sealant at sagardighi super speciality hospital, murshidabad
Tender For providing and installation of electrical accessories and allieds works at shaspur pwss, block-rampurhat-ii under bolpur mechanical division - supply, delivery at site and storage of wall mounted made of sheet steel fabricated 2 mm for load bearing & 1.6mm for non load bearing, indoor type, dust & vermin proof, lp-54 degree of protection, powder coated painted with rubber gaskets cover, front lockable hinged door with all switchgear and other items duly wired up and tested as per specification: incomer: (a) 100 amps, tpn mccb with adjustable ol, 36 ka, e/f, auto phase corrector & necessary accessories with suitable spd (i.e., ammeter, voltmeter, cts & switches), outgoing:- (b) 7.5 hp to 12.5 hp, tp star-delta starter with other accessories - 1 nos., (suitable size capacitor bank to improve pf from o.85 to 0.98) (c) yard lighting feeder with necessary accessories & time switch(digital) - 1 no. (d) 3phase actuator valve starter with other accessories -1 nos., (e) 2 hp ,3 ph,415v,clorinator feeder with necessary accessories & level controller-1 no., (f) 32a mccb fdr for iep/misc purpose-1no., (g) 32a mccb for in house light-1no.,(e) plc feeder with necessary accessories-1no.( all spare & components as per vendor list of phed), supply and delivery at site of 15 kva, 3phase, oil cooled type servo motor operated copper wound line voltage corrector conforming to is-9815 (pt.-1)- 1994 suitable for un-balanced input voltage with following specification including first filling oil as per is-335 where applicable.a) input voltage:- 3 phase, main supply may or may not be balanced with respect to phase to phase- 200v-500v phase to neutral-115v-290v.b) output voltage:-3 phase balanced output voltage. phase to phase- 400vor 415v 1%, phase to neutral- 230v-240v 1% (provision should be made to adjust the variation of output voltage per phase by a variable pot oil within 5% of output).c) line regulation:- out put voltage should remain well with 1% of set voltage (from minimum to maximum i.e. either 400v. or 415v. supply variation).d) load regulation : output voltage should remain neutral well within 1% of set voltage be ( from no load to full load ) i.e. either 400v. or 415v.e) correction speed:- better than 35 volt / second.f) efficiency:- better than 95% on full load.g) cut off limit (minimum &maximum ) by limit switch with audio & visual.h) metering indication:- by selector switch provision should be made available to measure input mains supply and output voltage other stabilizer for load current measurement an ammeter with selector switch should be available.i) lamp indication :- for input & output should be provided. ( 3 lamps per side ).j) mcb protection: for input side.k) load protection : hrc fuse on each output phase should be availablel) output over shoot:- beyond 210v to . 255v /phase in case of manual mode & voltage protection :auto mode operation.m) visual indication for under voltage & over voltage of output.n) manual mode:- up & down correction with o / p voltage over shoot protection. beyond 210 v-255 v. per phase.o) nature of cooling:- oil cooled system.p) electric current over load protection .q) circuit for delay output .r) input high voltage cut-off above 500 v.s) mode of operation:- auto/manual with a provision to restore the normal working of the unit standby operation should be available in case of any electronic failure in auto mode., installation of mcc panel along with main switch, changeover, busbar chamber, cut out etc. all electrical equipment within the pump house, drawing of cable properly on suitable size gi cable tray on wall / as per direction of eic as per layout & ie rules and all connection with supply necessary materials, cable etc to complete the work, making arrangement with supply & fixing of materials for taking power within the pump house from wbsedcl end as per direction of eic. [for ph no - i, ii & iii], installation of above supplied stab