Get complete information related to latest Lug Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Lug Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Lug Tenders.
Tender For supply of set of go and no go gauges for checking magnet frame dimensions, main pole bore diamet er and tm lug liner different gap (304.05 to 306.0mm) in hitachi traction motor of type hs15250a. set co nsists of 04 nos. go gauges and 04 nos. no go gauges. as mentioned in annexure. ]
Tender For supply of copper lug 70 square mm ( ring type) is :191 for manual metal arc welding machine is: 191: 2007 [ warranty period: 30 months after the date of delivery ]
Tender For corrigendum : supplying & installing nabl approved equipments for civil worktesting at piplaj hotmix plant for ahmedabad muncipal corporation.(amc) - electronic weighing balance -30 kg-1 gm, precision electronic balance-500 gm-0.01 gm (10 mg)-auto calibration, electronic weighing balance -5 kg-0.5 gm (500 mg), electronic platform balance-300 kg-50 gm-platform size 600 x 600 mm, high precision electronic balance -100 gm-0.001 gm (1 mg)- external calibration, water testing kit - hardness, water testing kit- sulphates, water testing kit chlorides, coarse sieves - 45 cm dia-g.i.-100.00 mm, fine sieve - 20cm dia-brass-10 mm, sieve shaker-gyratory-for 20/30 & 45cm dia sieves with digitaltimer, hot air oven-digital-45x45x45 cm-250c-inner s.s. chamber, liquid limit device - motorisedas per is : 2720 (partv) with revolution counter and grooving tools., pipette borosilicate glass - 1 ml, measuring cylinder - borosilicate glass - "0" bottom - 100 ml., water still-(ss 304)-(compact )-4 ltr/hour, compact cbr load frame-electrical-single speed, non nuclear density gauge (soil), rapid moisture meter-0 - 25 percentage with pressure gauge, standard penetration test apparatus with accessories - motorised, digital constant temp. waterbath for marshal test -6 moulds-100 mm, bitumen extractor - motorised with variable speed with digital rpm indicator with ac motor and drive, automatic compactor for marshal test - 4" dia specimen, unconfined compression tester-digital (marshal), ductility testing machine - digital temp control - refrigerated - is 1208, ring and ball apparatus-(programmable)-(digital)-(astm d36) with accessories, thin film oven - as per is 9382 as per is:9382., sand equivalent value test apparatus with accessories, sand equivalent mechanical shaker - motorized (astm d2419) with digital rpm indicator and digital timer, standard penetrometer for bitumen - automatic digital timer - dial gauge as per is 1203, is 1448. astm d5., saybolt viscometer - with digital controller and motorised stirrer - astm d88, pensky marten flash point apparatus-digital with motorised stirrer, asphalt content oven-(asphalt ignition oven)-(astm d6307), planetary mixer-for bituminous mix-digital- 20 ltrs, hardness tester for bitumen mastic asphalt with accessories, infrared thermometer - (-50c to 500 c), digital thermometer-(dtm 100)-300c-(cr/al (k))- with 12" long temp.probe, round hot plate-c.i. top-digital-20 cm, compression testing machine - 2000 kn-automatic pace rate controlled, compression testing machine - 2000 kn-digital - manual pacecontrol- auto calculation, cube mould-15 cm-isi marked u is:10086., concrete permeability tester - as per din 1048 - 3 cell - with air compressor, laboratory needle vibrato include 25mm needle with 6 meter long rubber shaft, laboratory concrete mixer-tilting drum type, vibrating table-100 x 100 cm, aggregate impact testing machine with blow counter, flow table (cement)-motorised - 25cm dia - m.s. top - is 5512, air entrainment meter - 0.005 cubic mtr - is: 1199 with accessories, los angeles abrasion testing machine - with presettable digital counter, riffle sample divider - g.i. 25mm - no. of slot : 16, electronic weighing balance -30 kg-1 gm, precision electronic balance-500 gm-0.01 gm (10 mg)-auto calibration, electronic weighing balance -5 kg-0.5 gm (500 mg), electronic platform balance-300 kg-50 gm-platform size 600 x 600 mm, high precision electronic balance -100 gm-0.001 gm (1 mg)- external calibration, water testing kit - hardness, water testing kit- sulphates, water testing kit chlorides, coarse sieves - 45 cm dia-g.i.-100.00 mm, fine sieve - 20cm dia-brass-10 mm, sieve shaker-gyratory-for 20/30 & 45cm dia sieves with digitaltimer, hot air oven-digital-45x45x45 cm-250c-inner s.s. chamber, liquid limit device - motorisedas per is : 2720 (partv) with revolution counter and grooving tools., pipette borosilicate glass - 1 ml, measuring cylinder - borosilicate glass - "0" bottom - 100 ml., water still-(ss 3
Tender For corrigendum : 21/2024-25 purchase of laqshya instrument - purchase of instrument ( laqshya), radiant warmer- technical specification of radiant warmer with baby bassinet a radiant warmer is used to keep the patient s core temperature stable at 37 o c. it should be microprocessor controlled radiant warmer with manual and servo options. it should have facility to display both skin and air (ambient) temperature separately.. it should have audiovisual alarm facility for overheating beyond set temperature range. it should have alarm facility for patient temperature less than or greater than the required temperature i.e. above or below the set range. it should rotate and swivel in different direction, so as to allow taking x-ray. the light should be dazzle free. it should have alarm for power failure. it should have alarm for heater failure and auto cut off for high temp. it should have alarm for probe failure. it should have time out alarm in manual mode. it should have facility to auto reset the system in case of hang up caused by power fluctuation. it should have manual setting for high and low alarm setting. in servo mode, the heater output should be controlled to maintain the baby at the required set temperature. in manual mode, the heater output should be directly controlled by a setting on the front panel should have a facility to lock the keyboard to avoid unwanted user. the desired temperature range from 25 to 40 degree c. the resolution should be 0.1 degree c halogen based observation light should be provided for observing the baby. it should be mounted on a pole with sturdy base with lockable castors power supply: power input to be 220-240 vac, 50hz fitted with indian plug. certificate of calibration and inspection from the factory. warranty: comprehensive warranty for 5 years after warranty documentation: user, technical, maintenance manuals to be supplied ce, iso certified , fetal doppler - technical specification of fetal doppler should be compact, table type and light weight. large lcd display for display of fetal heart rate. back light for better visibility display signal quality, low battery, etc., high sensitivity doppler probe of frequency 2.0 mhz ultra sound intensity 10mw/cm2. built-in speaker with output not less than 1.0w should work on rechargeable batteries with minimum battery time of 300minutes. battery charger and spare set of batteries aa type to be supplied. volume control facility and audio output for ear phone should be available. heart rate range should be from 50 to 240 b pm with accuracy of + /-2% should be water proof body. should have facility for fhr data transfer to pc. doppler probe should be light weight with holder facility when not in use. should be supplied with carrying case. machine should be iso mark, baby digital thermometer - technical specification of baby digital thermometer range 0.1 to 1000 degree centigrade measurement mode- min, max, average, differential, dual temperaturereading measurement unit- degree centigrade, degree fahrenheit,kelvin temperature probe with connecting cable relative humidity10 to 90% rh non-condensing ip rating- ip 40 g) probe response time 2-3 seconds it should be who & unicef standards, fetoscope - technical specification of infant fetoscope should be 135 75mm weight should be up to 350gm should be 40cm h20 presser limiting valve inspiratory resistance should be 5cmh2o (at 50l/min), delivery trolley/patient stretcher trolley- technical specification of patient stretcher trolley overall size: 1905mm l x 710mm w x 660mm to 910 mm h. stretcher dimension 1830 mm l x 555 mm w. two section top. height adjusted by foot operated maintenance free hydraulic pump. height adjustment shall be obtained by hydraulically operated mono block type linear actuator pump foot operated actuation having stroke of 140 +/- 5 mm, push force 10 kn at 270 bars, number of complete pump stroke 22 to 24 for full stroke length x-ray permeable removable stretcher, backrest raised on
Tender For supply of dial indicator (with lug back ), range : 0-50 mm (01 mm), graduation : 0.01 mm, dial reading +-00 - 100. make & model : mitutoyo (model no. 3058 s-19) or make & model : insize ( 2309-50) or similar [ warranty period: 30 months after the date of delivery ]
Tender For supply of plug as per drawing no-arde 9501-01 det. 11 , detonator holder as per drawing no-arde 9501-01 det. 9 , container exploder as per drawing no-arde 9501-01 det. 8 , plug fastening (for lug housing) as per drawing no-arde 9501-01 det. 5 sht. 2 , plug dummy (for lug housing) as per drawing no-arde 9501-01 det. 5 sht. 1 , base transit as per drawing no-arde 9501-01 det-13 , nose plug as per drawing no-arde 9501-01 det. 14 , lug housing holder as per drawing no-arde 9501-01 det. 4 sht. 2 , ring nut as per drawing no-arde 9501-01 det. 6 , lug housing as per drawing no-arde 9501-01 det. 4 sht. 1 , filling plug as per drawing no-arde 9501-01 det-7