Get complete information related to latest Lumbar Traction Kit Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Lumbar Traction Kit Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Lumbar Traction Kit Tenders.
Tender For corrigendum : sch 6 laboratory chemicals, stains, reagents, etc. by tender - sch vi (supply of laboratory chemicals, stains & reagent solutions) - sch vi (supply of laboratory chemicals, stains & reagent solutions), hydrochloric acid l.r., salicylic sulphonic acid a.r., sulphuric acid a.r.assay 96-98%, mac conkey s agar with 0.15% bile salt, with crystal violet and nacl., nutrient agar - bacteriological grade, ammonium sulphate a.r., dextrose (anhydrous) a.r., diethyl ether a.r. 99% pure, formaldehyde 40% a. r. (1x 25 ltrs), isopropyl alcohol a.r. 99-100%, potassium iodide a.r. 99.8%, xylol (extra pure) a. r., elisa kits for hbs ag.(3rd generation kits)- one step sandwich elisa using monoclonal antibody & conjug-ate coated wells., hydrochloric acid commercial grade for cleaning purpose., vdrl antigen kits containing stabilised emulsions of cardiolipin lecithin & cholesterol adjusted to required sensitivity.the result should be observable under microscope., elisa kit for detection igm antibody to pathogenic leptospirosis shelf life to be one year atleast at the time of receipt of kit., ultra sensitive hbsag elisa screening test capable of detecting escape mutants., direct bilirubin kit method-jendrassik & grofs end- point method (diazotised sulphanilic acid)reagent type-liquid stable / lyophilized minimum reconstitution stability-on board : 3 days after mixing r1 & r2 linearity -10mg/dl (ce mark on kit), blood urea nitrogenmethod-initial rate uv-kinetic methodreagent type-liquid stable / lyophilized minimum reconstitution stability-45 days at 2 to 8 degreeslinearity - 250mg/dl (ce mark on kit), creatinine method-initial rate alkaline picrate method reagent type- 2reagent liquid stable / lyophilizedminimum reconstitution stability-liquid stable reagentslinearity -30mg/dl (ce mark on kit), vibrio cholerase polyvalent 01 antisera, vibro cholerae ogawa antisera, vibro cholerae inaba antisera, salmonella polyvalent antisera (a-g), salmonella group 02 antisera, salmonella group 04 antisera, salmonella group 09 antisera, colistin mic (e-test) strips, mupirocin (200mcg), antisera clostridium species, antisera e. coli o157, spore strips (bacillus steothermophilus spores for steam sterilization-10 spores), iodine crystals, rapid test for detection of hiv-1 & hiv-2 ab s and p24 antigen from serum , plasma and whole blood. specificity and sensitivity of the test should be 100% for all sample types sample volume should be lessthan 50ulno buffer addition should be required for testing of serum and plasma samples.test should be who prequalified, nitrate reduction kit, dubos broth (tween 80), phenopthalein disulphate tripotassium, yeast nitrogen base agar (twin pack), rapid detection of salmonella typhi igg/igm antibody test, rapid detection of dengue ns1 antigen & igg/igm antibody test in same card (rapid dengue duo test), rapid test to detect mpt 64 antigen of mycobacterium tuberculosis complex, the test principlecould be immunochromatography or agglutination, dengue-chikungunya rtpcr kit, potassium tellurite blood agar, rtpcr kit for detecting dengue virus, rtpcr kit for detecting influenza a, h1n1, h3n2 & influenza b virus, viral rna extractionkit - automated,magnetic bead based compatible with kingfisher flex & hi media, rapid test for crypto+giardia+entamoeba, albumin bovine serum (a. r. grade ), sterile microtitre assay plate 96 well with lid clear round bottom non treated polypropylene, f-18 fdg (to be delivered to nuclear medicine department due to short half life when ordered ), colistin microbroth dilution test (ready to use predrug-coated plates), hepatitis b virus e antigen elisa (hbeag), cefotaxime e strip (0.016- 256 mcg/ml), ceftazidime avibactum e strip (0.016- 256 mcg/ml), chloramphenicol e strip (0.016- 256 mcg/ml), class v chemical indicators strips for steam sterilizers., distilled water, hepatitis b core igm elisa, manual nucleic acid extractionkit (silica column based), meropenem
Tender For bid to ras supply of silicon spray , aerosol spray for surgical instruments lubrication does not interfere in autoclaving process, bottle of 500ml , premoistened towelettes in dispenser containing alkyl dimethyl benzyl ammonium chloride, alkyl dimethyl ethyl benzyl ammonium chloride , sterilisation packing reel, heat sealable, see through, with one side medical grade paper and one side polymer, 45cm width, 200m reel , didecyl dimethyl ammonium chloride and n alkyl c14 50 percent, c12 40 percent, c16 10 percent dimethyl ammonium chloride , sterilisation packing reel, heat sealable, see through, with one side medical grade paper and one side polymer, 7 point 5cm width, 200m reel , class 6 chemical steam indicator strip, pack of 250 , helix chemical indicator with pcd for steam sterilization pcd of 1 point 5 mtr x 2mm diameter free with each pack of 250 indicators , sterilization wraps 91 x 91 cm packs of 200 , 3 line gun label compatible with plasma sterilisation, roll of 750 labels , sterilization wraps 121 x 121 cm packs of 200 , sterilisation packing reel, heat sealable, see through with one side medical grade paper and one side polymer,35 cm width 200m reel , autoclave tape indicator for steam sterilization , self contained biological indicator for steam sterlization providing failure result within 3 to 5 hours of incubation, box of 100 , bowie dick test pack, box of 30 lead free , thermoshield extreme mild alkaline enzymatic cleaner for surgical instruments ph greater than 10,with ce mark , sodium hypochloride 5percent , liquor formaldehyde 40 percent w slace v , surgiscrub, 500ml bott , propan 2 0l 0 g equals 72 vol percent banzalkonium chloride 0 point 025g purified water sunset yellow dye 500ml bott , chlorhexidine gluconate solution equivalent to 4 percent w slace v with isopropanol less than 10 percent, ethoxylated alkylphenol less than 10percent fatty acid , 0 point 5percent w slace v chlorhexidine gluconate in 70 percent v slace v ethyl alcohol with moisturizer 500 ml bott with dispenser , chlorhexidine gluconate 2percent in 70 percent isopropyl alcohol 100 ml bott , wipes containing 42 point 0g ethanal,0 point 05 gm dydeccyldimethayl amonium chloride for rapid disinfection 20 x 22cm canister for 100 wipes //bid details 2 / 26
Tender For corrigendum : supply of hysteroscopic instruments - supply of hysteroscopic instruments, diagnostic hysteroscope-- feature specification- outer diameter 2.7 mm - working length 250 mm 300 mm- angle of view: 30 - field of view wide-angle ( 80 )- image transmission rod lens system (preferred), or fiberoptic- sheath size 3.5 mm (outer sheath)- distension media normal saline or co (based on system compatibility)- light source connection standard fiber optic light post (compatible with xenon or led sources)- port type luer lock inflow port (optional outflow depending on model)- sterilization autoclavable or low-temperature plasma sterilization- material surgical-grade stainless steel and medical-grade polymers, operative hysteroscope (4 mm)- telescope diameter 4.0 mm- working length 270 300 mm- outer sheath diameter 5.5 mm (depending on continuous flow or single-flow sheath)- working channels 1 or 2 channels, standard 5 fr (1.7 mm) instruments- angle of view 30 (standard)- field of view wide-angle, distortion-free- image system rod lens optical system, hd-compatible- sheath type continuous flow (inflow and outflow channels)- material surgical-grade stainless steel- light transmission fiber optic light post, universal connector- distension media compatibility normal saline (for bipolar energy) or non-electrolyte fluid (for monopolar)- electrosurgical compatibility bipolar or monopolar electrodes (rollerball, loop, hook, etc.)- electrode type supported 5 fr electrodes resectoscope type- instrument compatibility operative scissors, graspers, biopsy forceps (5 fr)- sterilization autoclavable (134 c) or low-temperature plasma sterilization, hysteroscopic resectoscopesheath & telescopeouter diameter: 4.0 mm working channel: 1.5 2.0 mm (for scissors, biopsy forceps, graspers, bipolar electrodes)angle of view: 30 length: ~25 30 cmfibre optic light transmission with high-resolution rod lens systemresectoscope system (if using with loop / rollerball)available as mini-resectoscope (4.0 mm)compatible with bipolar energy sourceworking element: spring-loaded resectoscope with 4 mm telescopeelectrodes: loop, rollerball, knife, needle (bipolar compatible)fluid managementcompatible with saline (0.9%) as distension medium (for bipolar)continuous flow sheath for clear visioninflow/outflow channels for pressure-controlled irrigationother featuresautoclavable stainless steelergonomic design for operative stabilitycompatible with standard hd camera and light source systems, hysteroscopic scissors size: 5 fr (~1.7 mm), 30 36 cmpasses through working channel of 4 mm hysteroscope.types: straight / curved / angledmaterial: stainless steel, autoclavable, hysteroscopic biopsy forcepssize: 5 fr (~1.7 mm), 30 36 cm long.fits into working channel of 4 mm operative hysteroscope.types: biopsy (punch), grasping, scissors.jaws: serrated, single/double action, rotatable.reusable (autoclavable)., hysteroscopic morcellatorsystem componentshandpiece with cutting blade (rotating/reciprocating)inner cutting tube (sharp-edged) inside outer sheathcontinuous suction attached simultaneous cutting + tissue removalcompatible hysteroscope sheathdimensionssheath outer diameter: 6 7 mm (mini systems available with 5 mm)working channel: 3 3.5 mm (for morcellator blade)blade sizes: 2.5 3 mm (straight or side-facing cutting window)length: 26 30 cmoptics0 or 12 telescope, 2.9 4 mm rod lenshigh-definition fibre-optic illuminationenergy / working principlemechanical cutting continuous suction for clear vision and specimen collectionworks with normal saline as distension medium, hysteromat fluid management systemspecificationsmedium used: co (rarely now) or, preferably, fluids (normal saline, glycine, mannitol, sorbitol).pressure range: adjustable, usually 30 150 mmhg.flow rate: 50 500 ml/min (depending on model).display: digital display for set pressure, actual pressure, inflow, outflow, and fluid deficit.safety: audible alarms for excessive pressure or fluid deficit (to prevent ove