Web Analytics Made Easy - StatCounter

Lux Level Meter Tenders

Get complete information related to latest Lux Level Meter Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Lux Level Meter Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Lux Level Meter Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :37752530 Due date: 20 Nov, 202420 Nov, 2024 42.00 Lacs
Tender For corrigendum : sitc of 2 x 33 tr air cooled package type air conditioning plants - supply, installation, testing , commissioning of 33 tr capacity air cooled airconditioner , supply, installation, testing commissioning of 33tr capacity ,13200 cfm horizontal floor mounted double skin air handling unit , supply, installation, testing and commissioning of 3 phase vfd drives , supply and laying of 19 g copper pipe of size one and one eighth inches copper pipe for suction line with nitrile rubber insulation of 19mm thick , supply and laying of 19 g copper pipe of size five eighths inch with 13mm thick insulation for liquid line , supply, installation and testing of gss construction of 16g opposed blade volume control dampers , supply and installation of g.i perforated cable tray with top cover with supports , modification of existing plenum chamber , supply and installation of 32 mm dia cpvc or upvc drain piping insulated with 9mm nitrile rubber for ahu , supply installation testing and commissioning of electric control panel , supply and installation of remote status indication panel at control room , earthing , providing heat insulation treatment in ac plant room , providing under deck insulation , providing iron angle platform arrangement for outdoor condensing units , supply of 2 ft x 2 ft return air grills , provision of indicators for filter clogging and condenser clogging , dismantling and shifting of existing units , cooling towers, ahus , any other materials or works requirement to complete the sitc , belts for blower , pressure gauges for refrigerant and oil , dial type thermometer , air-filters , empty gas cylinder with regulating valve adopter and pressure gauge. , liquid line strainer , whirling psychro meter , anemometer , thermometer , valve key , thermal insulation of exposed duct out side the building bid number/ ( ( ) ): gem/2024/b/5460049 dated/* : 03-10-2024 bid document/ 2 1 / 28

corporations/Associations/Others

CTN :38202112 Due date: 27 Nov, 202427 Nov, 2024 NA
Tender For procurement of spares for abb make hydrogen gas purity meter for dstps,dvc,andal

CTN :38074178 Due date: 25 Nov, 202425 Nov, 2024 14.30 Lacs
Tender For corrigendum : supply of laboratory instruments at sstps (o and m), suratgarh- digital conductivity meter , poratble dissolved oxygen meter , poratble flue gas analyser

CTN :37815711 Due date: 22 Nov, 202422 Nov, 2024 NA
Tender For corrigendum : procurement of 1200 scmh gas engine driven cng compressors - 1200 scmh skid mounted gas engine driven cng compressor package-item 1.1 of mr , lcv trailer panel complete with mass flow meter-item 1.2 of mr , transportation upto delivery location and other costs incidental to delivery of goods for item no. 1.1 , transportation upto delivery location and other costs incidental to delivery of goods for item no. 1.2 , installation, commissioning and field performance test-item 2.1 of mr , operation charges for compressors for cachar ga for 1st year -item 3.1 of mr , operation charges for compressors for cachar ga for 2nd year -item 3.2 of mr , operation charges for compressors for cachar ga for 3rd year -item 3.3 of mr , operation charges for compressors for cachar ga for 4th year -item 3.4 of mr , operation charges for compressors for kamrup ga for 1st year -item 3.5 of mr , operation charges for compressors for kamrup ga for 2nd year -item 3.6 of mr , operation charges for compressors for kamrup ga for 3rd year -item 3.7 of mr , operation charges for compressors for kamrup ga for 4th year -item 3.8 of mr , annual comprehensive maintenance charges for compressors for cachar ga for 1st year -item 4.1 of mr , annual comprehensive maintenance charges for compressors for cachar ga for 2nd year -item 4.2 of mr , annual comprehensive maintenance charges for compressors for cachar ga for 3rd year -item 4.3 of mr , annual comprehensive maintenance charges for compressors for cachar ga for 4th year -item 4.4 of mr , annual comprehensive maintenance charges for compressors for kamrup ga for 1st year -item 4.5 of mr , annual comprehensive maintenance charges for compressors for kamrup ga for 2nd year -item 4.6 of mr , annual comprehensive maintenance charges for compressors for kamrup ga for 3rd year -item 4.7 of mr , annual comprehensive maintenance charges for compressors for kamrup ga for 4th year -item 4.8 of mr

Central Government/Public Sector

CTN :37985106 Due date: 25 Nov, 202425 Nov, 2024 NA
Tender For corrigendum : supply of orifice type gas flow meter (with installation & commissioning) , orifice type gas flow meter (without installation & commissioning)

Central Government/Public Sector

CTN :38163391 Due date: 20 Nov, 202420 Nov, 2024 32.84 Lacs
Tender For provision of air conditioners water coolers and misc items at kushinagar international airport - supply , installation , testing & commissioning of 5 star , 1.5 tr high wall type split inverter air conditioner unit with rotary compressor operating on refrigerant r-32/non cfc & copper condensor coil of outdoor unit & having cordless lcd remote , auto restart operation with copper refrigerant gas pipeline insulated with nitrile/polythene foam i/c electrical cable of suitable size copper conductor from indoor to outdoor unit (both upto 10 feet ) i/c standard drain pipe , ms base frame / platform duly epoxy painted for outdoor units suitable for operation on 230v , 50 hz single phase ac supply and capable of performing such standard function like cooling , dehumidifying , air circulating etc complete as required. , supply and fixing of extra copper refrigerant piping (beyond the standard length) complete with suction/ liquid line along with insulation and electrical cabling with pvc protection piping for cable and all accessories required for 1.5 tr as per site requirement. , supply , installation , testing & commissioning of 5 star , 2 tr high wall type split inverter air conditioner unit with rotary compressor operating on refrigerant r-32/non cfc & copper condensor coil of outdoor unit & having cordless lcd remote , auto restart operation with copper refrigerant gas pipeline insulated with nitrile/polythene foam i/c electrical cable of suitable size copper conductor from indoor to outdoor unit (both upto 10 feet ) i/c standard drain pipe , ms base frame / platform duly epoxy painted for outdoor units suitable for operation on 230v , 50 hz single phase ac supply and capable of performing such standard function like cooling , dehumidifying , air circulating etc complete as required. , supply and fixing of extra copper refrigerant piping (beyond the standard length) complete with suction/ liquid line along with insulation and electrical cabling with pvc protection piping for cable and all accessories required for 2 tr as per site requirement. , supply and fixing of 20 mm. dia. u-pvc plumbing/drain pipes required for 1.5 tr split acs on surface including all accessories like bends , sockets and water seal joints etc. complete as required. , supply and fixing of 4 kva automatic digital voltage stablizer having working range 170-270v and complete with connections , testing and commissioning etc. as suitable for 1.5 ton split type air conditioner as per aai preferred make list. , supplying and fixing 20 a , 240 v , spn industrial type socket outlet , with 2 pole and earth , modular type plug top alongwith 20 a c curve , sp , mcb , in pvc box/enclosure , on surface or in recess complete with connections , testing and commissioning etc. as required. make havells , model dboxx mcb protected pvc plastic base model (white) , asin b07bvkq17h or equivqlent. , wiring for circuit/ submain wiring alongwith earth wire with the following sizes of frls pvc insulated copper conductor , single core cable in surface/ recessed steel conduit as required. 2 x 4 sq. mm + 1 x 4 sq. mm earth wire , supply , installation , testing and commissioning of 4.0 tr air-cooled tower/ standing type ac alongwith vibration isolator , as per latest bee standard fitted with 100 percentage copper condensing unit comprising of sealed rotary type compressor with inverter technology and non cfc refrigerant like r410a suitable for stabilizer free operation at 3ph , 415v , 50hz ac supply as required , including supply of power cable , copper piping upto 3 meter and drain pipe upto 3 metre both copper pipe and drain pipe separately enclosed in with nitrile ruber insulation including wrapping in white vinyl tape power cabling between indoor and outdoor upto 3 metre , all necessary ms structure for supporting units , anchor fasteners , nut , bolts , with outdoor stand and ms stand painted with anti-rust paint for mounting outdoor units etc. complete as re

Central Government/Public Sector

CTN :37792095 Due date: 18 Nov, 202418 Nov, 2024 10.25 Lacs
Tender For corrigendum : supply of general equipment - digital thermometer , needle cutter or hub cutter , esr tubes with stand , neubauers counting chamber , micropipette 0.1 to 2 microliter , micropipette 1 to 10 microliter , micropipette 5 to 10 microliter , micropipette 50 to 200 microliter , micropipette 200 to 1000 microliter , multi-channel pipette 200-1000 microliter octa pipette , ph meter , gas supply lpg , bunsen burner , glassware, kits and consumables , alcohol thermometer , alarm clock , slide staining racks , electronic balance , computer with ups, printer all in one , air conditioner

CTN :38152137 Due date: 29 Nov, 202429 Nov, 2024 NA
Tender For supply of contactor forty amp four forty volt coil - contactor forty amp four forty volt coil , contactor twenty five amp four forty volt coil , contactor forty amp two twenty volt coil , contactor twenty five amp two twenty volt coil , over load relay mk one l and t six to twenty amp , coil contractor bch four forty volt , coil contractor bch two twenty volt , contractor points bch forty volt , mcb forty amp four pole , mcb forty amp two pole , mcb thirty two amp one pole , mcb box four pole cab tree , mcb box two pole cab tree , four mm sq pvc wire , plastic gitti one point five inch and two inch , wood screw one inch and one point five inch , one point five mm sq pvc three core copper cable , two point five mm sq pvc three core copper cable , four mm sq pvc four core cable , dol stater mk one l and t , nails five point zero mm by fourteen swg , nails three point seven mm by thirteen swg , gypsum screw half inch one inch one point five inch , pendant holder brass , copper brush for drill machine , carbon brush for pipe cutter , amp meter digital with ct sixty five mm into sixty mm , volt meter digital sixty five mm into mm , capacitor hundred by one twenty mfd , hundred w electric bulb , soldering wire , heat sink seelve one point five mm , heat sink seelve two point five mm , heat sink seelve ten mm , contact cleaner , rust remover wd forty , electronic timer , cable tie zero eight inch , ferule lug one to ten mm , cu lug four mm sq ring type , cu lug ten mm sq , fuse wire twenty three no , four pole ht forty amp connector backlite , five pole ht thirty amp connector backlite , battery lead red fifty mm sq , battery lead black forty mm sq , main switch sixty three amp tpn havells , main switch thirty two amp tpn havells , bch aux point set one no plus one nc , battery terminal positive , battery terminal negative , banana connector red , banana connector black , refrigerent gas r one thirty four a , transformer twelve zero twelve one amp , relay twenty five amp

CTN :38133868 Due date: 27 Nov, 202427 Nov, 2024 NA
Tender For supply of gen set - 6625 002404 volt meter , 6625 001557 ampere meter , ixc atr 0es 1102 start pilot , 4820 001133 cock fuel gun , nk003066 fan belt , nk003067 feed pump , nk000724 overflow pipe , nk003068 fuel pipe , nk003069 stopper cable , nk003070 fuel cock , nk003071 ac gas 134 , 6240 000708 comp filament , ixc lvc 26921007a dynamo assy , ixc luc sp 29c starter assy , ixc m1430261031 nozzle , nk003072 spring tow , nk000726 pump element

CTN :38127165 Due date: 28 Nov, 202428 Nov, 2024 5.97 Lacs
Tender For supply of laboratyr and scientific instruments/tools - laboratory and scientific instruments/tools, compressor: type: refrigeration compressor, hermetically sealed, reciprocating, refrigerant type: r22, cooling capacity: 2355 kcal/hr type, voltage 220-240 v ac, 1- phase (details as per sl. no. 1 at annexure-i)., compressor: type: refrigeration compressor, hermetically sealed, reciprocating, refrigerant type: r134a, cooling capacity: 1411kcal/hr, voltage: 440vac, 25mfd, 1- phase (details as per sl. no. 1 at annexure-i)., compressor: type: refrigeration compressor, hermetically sealed, reciprocating, refrigerant type:r134a, cooling capacity: 0.25hp; supply voltage: 220-240 v ac, 1- phase (details as per sl. no. 1 at annexure-i)., capillary tube : 1.12 mm od, material: copper astm b280 (details as per sl. no. 2 at annexure-i)., capillary tube : 1.20 mm od, 8 ft, material: copper astm b280 (details as per sl. no. 2 at annexure-i)., capillary tube : 1.40 mm od, material: copper astm b280 (details as per sl. no. 2 at annexure-i)., capillary tube : 0.95 mm od, material: copper astm b280 (details as per sl. no. 2 at annexure-i)., thermostatic expansion valve: orifice- 0 no., connection-1/2 x 3/8 flare (details as per sl. no. 3 at annexure-i)., thermostatic expansion valve: ten 068z3348, q-33311 r134a -40 to 10 ps 34 bar. (details as per sl. no. 3 at annexure-i)., hand stop /manual shut-off valve: media: r22, r502, r134a, r407c, r410a; port size: 3/8" sae; cooling method: direct cooling; power: manual; including brass material nut bolt. (details as per sl. no. 4 at annexure-i)., hand stop /manual shut-off valve: media: media: r22, r502, r134a, r407c, r410a; port size: 1/4" sae; cooling method: direct cooling; power: manual; including brass material nut bolt. (details as per sl. no. 4 at annexure-i)., evaporator coil : 1/4" od, material: copper astm b280 (details as per sl. no. 5 at annexure-i)., condenser coil ; 3/8" od, material: copper astm b280 (details as per sl. no. 6 at annexure-i)., dimmer stat : 1500 w, 230 v ac. single phase, 50hz (details as per sl. no. 7 at annexure-i)., pressure gauge : connection 1/ npt 8 0 - 200 psi dial size 2.5" (63mm), connection sizes 1/4" (details as per sl. no. 8 at annexure-i)., digital temperature indicator : range -30 to 200 0c, power supply 230vac, digital display, accuracy 0.01 c channel -12 (details as per sl. no. 9 at annexure-i)., digital temperature indicator : type input cr-al(k-type), rang- 0 0c to 200 0c supply- 230vac, 50hz, channel -12 (details as per sl. no. 9 at annexure-i)., ammeter (digital) : rang 0-10 amp. single phase, digital display, 230v,10%vac (details as per sl. no. 10 at annexure-i)., voltmeter (digital) : rang 0 300-volt, single phase, digital display (details as per sl. no. 11 at annexure-i)., hp/lp cut out relay : hp- 8 to 32 bar, lp-0.2 to 7.5 bar, dual controls, 240 v, 50 va, single pole changeover switch (spdt), contact load 240 v ac: 8 fla, 48 lra (details as per sl. no. 12 at annexure-i)., energy meter : a.c. single phase, 2 wire solid state (static) fully electronic energy meter, accuracy class 1.0 & current rating 5-30 amp. with backlit lcd display for240 volt system fitted with pilfer proof meter box.(details as per sl. no. 13 at annexure-i)., r-134a refrigerant gas : 5 kg filled cylinder; moisture less than 0.001; purity: 99.9%; appearance: colourless; application: refrigerant; type of refrigerant-r134a. (details as per sl. no. 14 at annexure-i)., r-141b refrigerant gas : 5 kg filled cylinder; purity 99.9% appearance: colourless (details as per sl. no. 15 at annexure-a)., r502 refrigerant gas : 5 kg filled cylinder; acidity 0.00001 % appearance: colourless purity 99.9 % (details as per sl. no. 16 at annexure-i)., r407c refrigerant gas : 5 kg filled cylinder; appearance: colourless purity 99.9 % (details as per sl. no. 17 at annexure-i)., r-1234ze hfo refrigerant gas : 5 kg filled cylinder; moisture less than 0.001; purity: 99.9%; appearance: colourless; (de
 Loading, Please wait...

Connect us via What's Up