Get complete information related to latest Lv Cable Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Lv Cable Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Lv Cable Tenders.
Tender For annual rate contract for the year 2025-26 - supply, installation, testing & commissioning of 11/0.433kv, 25 kva 3-phase distribution transformers with bimetallic terminal connectors energy level-2, aluminium wound, and with lvcable box having detachable aluminium gland plate with lv bimetallic terminal connection suitable for vertical take off of cable., supply, installation, testing & commissioning of 11/0.433kv, 3-phase, 63kva distribution transformer with bimetallic terminal connectors energy level-2, aluminium wound , and with lvcable box having detachable aluminium gland plate. transformer should have arrangement for vertical take off, supply, installation, testing & commissioning of 11/0.433kv, 3-phase, 100kva distribution transformer with bimetallic terminal connectors energy level-2, aluminium wound , and with lvcable box having detachable aluminium gland plate. transformer should have arrangement for vertical take off, supply, installation, testing & commissioning of 11/0.433kv, 3-phase, 200kva distribution transformer with bimetallic terminal connectors energy level-2, aluminium wound , and with lvcable box having detachable aluminium gland plate. transformer should have arrangement for vertical take off, supply, installation, testing & commissioning of 11/0.433kv, 3-phase, 250kva distribution transformer with bimetallic terminal connectors energy level-2, aluminium wound , and with lvcable box having detachable aluminium gland plate. transformer should have arrangement for vertical take off, sitc of 11 mtr long st poles 410, sp-56 including transportation, manual, mechanical carriage, delivery at site with pit excavation, refilling the pit with soil, boulders., sitc of 9 mtr long st poles 410, sp-33 including transportation, manual, mechanical carriage, delivery at site with pit excavation, refilling the pit with soil, boulders., sitc of 8 mtr long st poles 410, sp-15 including transportation, manual, mechanical carriage, delivery at site with pit excavation, refilling the pit with soil, boulders., providing of earthing complete by gi pipe/ gi rod 40 mm 3 mtr long through gi strip 25x3 mm as per rec standards., supply and painting of each pole 1 coat red oxide paint and 2 coats of aluminum paint (@ 1 ltr/pole red oxide paint and 1 ltr/pole aluminum paint) inscribed with permanent marking on each pole "name of scheme-2024-25/xx" (xx mean pole numbers say 01, 02...) in white paint in background of green paint at conspicuous place. the paint shall have to be sprayed not brushed., sitc of gi channel cross arms, v-cross arms, sub-station channels & angle iron braces, transformer beltings, including back clamps for fixing cross arms etc. fabricated out of galvanized iron of different sizes (rec standard) & to be fixed with gi nuts & bolts and washers., sitc of 11kv polymeric composite pin insulator 12kv, 5kn, lighting impulse 75kv positive and 80kv negative, creepage distance 320mm, sitc of 11kv polymeric composite disc insulator 12kv,min failing load 45kn, lighting impulse 75kv positive and 80kv negative, creepage distance 320mm with fitting, providing & fixing of mucki clamps/lt shackles with insulators, providing & fixing of 11 kv horn gap fuse set 3 phase 200a, providing & fixing of 11kv go, ab switch 3-phase, 3-pole, 200 amp, vertical type, providing & fixing of 11kv gapless surge arrestor, 9 kv ,10 ka, la with polymer housing, stn. type, providing & fixing of lt fuse set, providing & fixing of single core aluminum (al.) lt power cable (1.1 kv grade) 300 mm sq cross section un-armored xlpe cable with thermoplastic tape inner sheath from the lt bushes upto the overhead lt bare conductor., providing & fixing of single core aluminum (al.) lt power cable (1.1 kv grade) 185 mm sq cross section un-armored xlpe cable with thermoplastic tape inner sheath from the lt bushes upto the overhead lt bare conductor., providing & fixing of single core aluminum (al.
Tender For 1)supply of two nos. of out door type 750kva, 11kv/415v, onan auxiliary transformer along with oil as per site requirement 2)supply of lt copper power cable 400v, 1.1kv grade pvc armored 3.5 core 2rx 400 sqmmm along with lvcable termination accessories,lugs etc 3)dismantling of existing 2 nos. of 750kva auxiliary transformers and old oil cooled cables at ltac panel and auxiliary transformer end and its accessories 4) laying of lt copper power cables and termination of cables along with supply of all accessories for laying of cables 5)erection, cabling, testing and commissioning of 2 nos. of 750kva,11kv/415v auxiliary transformers 6)buy back of released two nos. of 750kva auxiliary transformers along with oil
Tender For supply installation testing and commisioning of vrf system - vrf outdoor unit 14 hp , vrf outdoor unit 40 hp , vrf outdoor unit 42 hp including scrap value , vrf outdoor unit 50 hp , vrf outdoor unit 54 hp , vrf outdoor unit 60 hp , vrv indoor unit 1 point 05 tr , vrv indoor unit 1 point 32 tr , vrv indoor unit 2 point 07 tr , vrv indoor unit 2 point 65 tr , vrv indoor unit 3 point 30 tr , vrv indoor unit 4 point 12 tr , high wall type indoor unit 2 point 0 tr , treated fresh air 1700 cfm , connection kit , vrf outdoor unit 42 hp , indooor unit cassette type , tfa tye , refrigerant piping , control and transmission wiring 2 core x 0 point 75 hyphen 1 point 5 sq mm , drain piping 25 mm , 32 mm , exhaust fan 4500 cfm , exhaust fan 1200 cfm , gi ducting 24 g thickness 0 point 63 mm sheet , air duct thermal insulation , flexing canvas , anti vibration stand for outdoor units , modification of existing electrical panel , power cable 4 core x 10 sq mm , power cable 4 core x 16 sq mm , camc 1st year , camc 2nd year , camc 3rd year , camc 4th year , camc 5th year
Tender For repair of transformer 400 kva outdoor type at af stn memaura : : - disconnecting of hv or lvcable from transformer 400 kva 11or 0point433 kv at site and loading and unloading of transformer at both side s or s a of age i af memaura and repair work premises hiring of crane and transportation charges to workshop from agei af memaura complete all as specified and directedpoint make vishal transformers switchgears pvt ltd sm nopoint 1843089tr04 01 each job , taking down and dismantlingopening up unserviceable transformer step down outdoor type 110point433 kv capacity 400 kva including lifting of core taking out unserviceable burnt winding after dismantling core stampings and draining of transformer oil and storing in a suitable container desludging and cleaning thoroughly rewinding and reinsulating of transformer as per the requirement maintaining existing specificationsize including reassembling core stampings lowering wound core within transformer outer cell and refilling transformer oil after sludge removal of dielectric strength 50 kv at least replacement of silica gel of breather reassembling testing for satisfactory performance and installation and commissioning in the existing position complete all as directedpoint note materials required for winding and insulation shall be measured and paid separately as supply only 01 each job , m l for changing of old burnt copper coil by new dpc copper coils with complete including insulation material of distribution transformer of capacity 400 kva complete all as specified and directedpoint 107 kg , dismantling of unserviceable lt bushing of transformer of capacity 400 kva and supply and fix new bushing including brass stud nuts washers and rubber bush complete all as directed by the engineerinchargepoint 02 each set , dismantling of unserviceable 11 kv ht bushing of transformer of capacity 400 kva and supply fix new bushing including brass stud nuts washers and rubber bush complete all as directed by the engineerinchargepoint 01 each set , supply and pour new transformer oil in replacement of approved quality dielectric strength not less than 50 kv isi marked for filling in transformer for topping up complete all as specified and directedpoint 370 ltrs , schedule of credit for old us items will be the property of contractor
Tender For auction sale of unserviceable cables of different types (pph-1),old and damaged copper stator coils with insulation (mdy-1),insulated copper control cable (kdt-1),pvc insulated copper cable unserviceable (mlm-1),unserviceable telephone copper cable scrap (mlm-2),permanent magnet generator- (mlm-3),copper scrap (lpp-2)