Get complete information related to latest Lvdt Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Lvdt Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Lvdt Tenders.
Tender For provision of auxiliary transformer with accessories in connection with replacement of auto signaling by using multi section digital axle counter (msdac) at cgr-bdc automatic section for 02 nos huts in howrah division of eastern railway.
Tender For providing of custom bid for services - amc - nitrogen psa plants molsieves make; supply of items: service charges/visit, changeover valve, 40 mm, changeover valve, 25 mm, changeover valve, 15 mm, auto shut valve, 15 mm, valve, 2 way 5 port, valve, 2 way 3 port (cu), valve, 2 way 3 port(psa), 3 way valve, 15 mm, nrv valve, 50 mm, nrv valve, 25 mm, pressure gauge, 0-10 kg, supply and installation of cms, pressure gauge, 0-21 kg, air filter , 1st stage, air filter , 2nd stage, air filter, 3rd stage, glass tube for psa, glass tube 1 for cu unit, glass tube 2 for cu unit, sply and loading of software, mass flow meter, glass tube h2, controller, rtd sensor, pressure switch, 0-10 bar, pressure switch, 0-5 bar, pressure switch, 8-28 bar, h2 pressure switch, 0-5 br, seal kit, 25 mm, seal kit, 15 mm, sply of o2 analyzer, seal kit&seat, 40 mm, seal kit&seat, 25 mm, seal kit&seat, 15 mm, seal kit bpc valve,25 mm, seal kit bpc valve,15 mm, supply and instln of charcoal, supply and instln of alumina, sply&instln of copper catalyst, sply and instln of fine filter, sply&instln of heating element, fuse link, lamp, relay card, annunciator, ammeter, transformer, switch, relay, 32 a contactor, 16 a contactor, transmitter, gasket set, mass flow meter n2, dp flow meter orifice, modulating valve, analogue card, rotameter n2, rotameter h2, filter cum pressure regulator, auto drain valve (ac), needle valve upto 1/2" ss304, needle valve 25mm ss304.
Tender For corrigendum : supply of 1. add on block 1nc contact part no b si 00592 , 2. triple pole three way with off rotary switch rated 6a part no b sz 10766 , 3. hrc fuse holder rated 20a part no e si 03010 , 4. hrc fuse link rated 2a part no e si 03197 , 5. single phase double wound control transformer pri 380 230 115v sec 24v 50va part no m di 00074 , 6. withdrawable operating coil 380 420 ac part no c si 00715 , 7. withdrawable operating coil 380 420 ac part no c si 00716 , 8. auto changeover card 380v ac part no u vtv 00028
Tender For corrigendum : supply of ohm meter , ac voltmeter , milli voltmeter , ammeter mc , ac ammeter , kilo wattmeter , digital wattmeter , ac energy meter single phase , ac energy meter three phase , power factor meter digital , frequency meter , magnetic flux meter , lux meter , tachometer , tong tester , megger , dc starter , wheat stone bridge , single phase variable auto transformer , phase sequence indicator , growler , ac starters , soldering iron , temperature controlled , discrete component trainer , linear ic trainer , domestic appliance , oil testing kit , inverter with battery , voltage stabilizer , dc power supply , battery charger , current transformer , potential transformer , solar panel with battery , computer , laser printer , dc shunt generator , motor generator ac to dc , dc compound generator with control panel , dc series motor coupled , dc shunt motor , dc compound motor with starter , motor generatordc to ac , ac squirrel cage motor with star delta starter , ac phase wound slip ring motor with starter , universal motor with starter switch , synchronous motor with accessories , thyristor igbt controlled , thyristor igbt controlled ac motor drive , single phase transformer core type air cooled , three phase transformer shell type oil cooled with delta star , ac series type motor , single phase capacitor motor with starter , manual motor coil winding machine , ceiling fan coil winding machine , primary current injection set , stepper motor with digital controller , shaded pole motor , smart meter , ev charger , ev charger home
Tender For corrigendum : supply of instrument mechanic im c c - trainer on basic digital electronics i e logic gates , trainer on power suppliers half wave rectifier , scr driven or controlled power supply trainer , potentiometer or thermocouple test set , auto transformer , calibration test bench for ac and dc voltmeter , bourdon tube type gauges of various ranges , dead weight tester and comparator , differential pressure transmitter electronic- hart or field bus type , pressure transducers training kits , experimental set up for pressure measurement , hart device communicator and calibrator , pneumatic calibrator , pressure switches of various ranges , p to i converter and i to p converter , vacuum tester with pump , simple tank quantity meter , impeller type flow meter , helical and turbine flow meter , magnetic flow meter , vortex flow meter , flow control loop set with flow controller recorder , experiment closed loop set up solid flow measurement and control , corioils mass flow meter , flow nozzle , static pressure and air type purge type level indicator , level transmitter interface hart compatible , level control set up with transmitter and level recorder , level measurement eequipments for solid , experimental set up for measuring and controlling of temperature , paper less lcd or led recorder setup , real pid controller trainig kit , programmable logic controller , hart or filed devices , hydrauilc actuators , different type of control valves such as gate valves , valve positioner , hart or filed bus final control elements , data acquisiton syastem , adc to dac cards , digital i or o cards , conductivity meter and tds meter , experimental set up for online conductivity measurement , experimental set up for online ph measurement , experimental set up for online dissolved oxygen measurement ) /bid number: gem/2025/b/6999540 * /dated: 15-12-2025 & & / bid document1 / 38
Tender For auction sale of eletrical moters and spares scrap,plastic salt bags and liner scrap,used paper scrap,m s barrels scrap,lab over scrap lab ovenhot air oven, auto clave etc,bottle coolers/freezer,artificial insemination container with aluminum scrap ta55, ba55, ba20..etc,amcu (auto milk collection unit) spares scrap,aluminum material scrap,broken plain glass,ms material,ss material,paneer coagulation tanks,milk balance tanks,can scrubber,casein tank,voltage stabilizer with transformer,air compressor with motor,air dryer
Tender For corrigendum : provisioning of electrical and mechanical eqpt against ber under ge 862 ews - supply, installation, testing and commissioning of serve controlled voltage stabilizer (confirming to bis 9815 (part-1) 1994, reaffirmation 2019 latest version) three phase, four wire (rybn), 50 hz, naturally oil cooled, outdoor, unbalanced type, cooper wound, metallic body duly power coated with lifting hooks two nos, digital display type, relay free smooth and silent operation with 1st filling of transformer oil up to level having following specification:-(a) capacity 300 kva (b) type - suitable for unbalanced load and unbalanced input(c) input voltage -360v-480v, input frequency 50 hz (d) output voltage - stabilized at any deigned/ desired voltage 415/+-1% (e) rated frequency - 50 hz(f) wave form distortion - nil (g) response time - not to exceed 20 milli seconds(h) sensitivity - (+/-) 1% (j) rate of correction - not less than 6 volt/second between phase and neutral (k) efficiency - more than 95% (l) type of load - three phase, unbalanced type(m) metering - digital display voltmeter/ammeter with multi-functional meter (n) operating temperature - for indoor use upto max ambient temp + 55 c (o) dimmer rating - 450 amp (p) dimension of tanks - as per oem design(q) oil capacity- as per oem design , (r) class of insulation - class f (s) mode of operation automatic/manual (t) winding temperature rise - max 55 c (10 c above operating temp) (u) transformer oil -is 335 marked (v) core-crgo m4 grade/crno (cold roll grain oriented)/ (cold rolled non-oriented)(w) auto transformer (variac) -100 percent copper wound electrolytic grade(x) losses - as per is norms (y) power factor - not less than 0.95(z ) protection - (i) over load protections (ii) short circuit protections (iii) high/low voltage cut off (iv) by pass arrangement in case of emergency (v) single phase sequence change /phase fail protection (vi) earth fault protection(aa) standard fitting & accessories e.g marking plate, lifting lugs, ci rollers, earthing terminals, cable box including suitable platform as reqd on site complete all as as specified & directed., supply, installation, testing and commissioning of serve controlled voltage stabilizer (confirming to bis 9815 (part-1) 1994, reaffirmation 2019 latest version) three phase, four wire (rybn), 50 hz, naturally oil cooled, outdoor, unbalanced type, cooper wound, metallic body duly power coated with lifting hooks two nos, digital display type, relay free smooth and silent operation with 1st filling of transformer oil up to level having following specification:-(a) capacity 100 kva (b) type - suitable for unbalanced load and unbalanced input(c) input voltage -360v-480v, input frequency 50 hz (d) output voltage - stabilized at any deigned/ desired voltage 415/+-1% (e) rated frequency - 50 hz(f) wave form distortion - nil (g) response time - not to exceed 20 milli seconds(h) sensitivity - (+/-) 1% (j) rate of correction - not less than 6 volt/second between phase and neutral (k) efficiency - more than 95% (l) type of load - three phase, unbalanced type (m) metering - digital display voltmeter/ammeter with multi-functional meter (n) operating temperature - for indoor use upto max ambient temp + 55 c (o) dimmer rating - 150 amp (p) dimension of tanks - as per oem design(q) oil capacity- as per oem design , (r) class of insulation - class f (s) mode of operation automatic/manual (t) winding temperature rise - max 55 c (10 c above operating temp) (u) transformer oil -is 335 marked (v) core-crgo m4 grade/crno (cold roll grain oriented)/ (cold rolled non-oriented)(w) auto transformer (variac) -100 percent copper wound electrolytic grade(x) losses - as per is norms (y) power factor - not less than 0.95(z ) protection - (i) over load protections (ii) short circuit protections (iii) high/low voltage cut off (iv) by pass arrangement in case of emergency (v) single phase sequence change /phase fail protection (vi) earth fault protection(a
Tender For providing plinth for ah tower, vc, wc structure, equipment and transformer plinth, supply and erection of ah tower with boom and allied civil works for enhancement of existing auto transformer capacity at existing kurukkathi 230kv ss - providing plinth for ah tower, vc, wc structure, equipment and transformer plinth, supply and erection of ah tower with boom and allied civil works for enhancement of existing auto transformer capacity from 1x100+1x80 mva to 2x100mva+1x80 mva at existing kurukkathi 230/110 kv ss.