Tender For corrigendum : annual maintenance and rectification of generator control panels for lakshadweep electricity department during the year 2026-28
Tender For corrigendum : tender for supply of design and engineering of imcc panel 2 nos and vfds and plc network , design and engineering of apfc and hvac , design and engineering of apfc and field instruments , design and engineering of cables and termination and airconditioning for imcc building , design and engineering of earthing of imcc , field equipments and soil testing , design and engineering of civil buildings and structure foundations , design and engineering of imcc building with earthing system , design and engineering of structural works for cable laying for both incoming and outgoing cables , design and engineering of lighting system of imcc building , equipment locations at ccr ground floor and along the structural path for cable route , design of fire detection and alarm system for building and cable alley area along with integration and display at fire station/existing control centre , supply of imcc panels , vfd panels , supply of apfc panels , hvac system/ air conditioning systems for imcc building and other area air conditioners as mentioned in scope of work , supply of mldb , lighting distribution boards , lighting material including db , light fittings , and all related accessories or wiring material and other electrics etc , supply of field instruments and necessary piping materials as required , supply of plc and other related required accessories , supply of lt cables and other related accessories for electrical , termination material and other instrumentation cables etc and other related electrics as required , supply of cable trays for electrical and instrumentation , supply of all earthing material as per is 3043 for imcc and connection to earth pits for motors , panels etc , supply of fire detection and alarm system for building and cable alley area along with integration and display at fire station/existing control centre , erection , testing , commissioning , and handover of equipments of imcc panels and vfd panels , erection , testing , commissioning , and handover of equipments of apfc panels and hvac system , erection , testing , commissioning , and handover of equipments of lighting system as per above supply , erection , testing , commissioning of earthing system , erection , testing , commissioning of field instruments and necessary piping materials etc as required , erection , testing , commissioning and handover of plc , erection , laying , testing and commissioning of lt cables cable terminations wherever required along with necessary accessories is in the scope of the contractor for electrical and instrumentation , erection , testing and commissioning of cable trays for electrical and instrumentation , erection , testing and commissioning of fire detection and alarm system for building and cable alley area along with integration and display at fire station or existing control centre , substructure excavation , foundation works footings , columns up to plinth level , dpc damp proof course , and backfilling. , superstructure columns , beams , slabs , brickwork or masonry for all floors above plinth level , and formwork up to ground floor , finishes plastering , flooring tiles , marble , painting , wall cladding , and other interior or exterior finishes , plumbing works , fixing of doors up to ground floor. , superstructure columns , beams , slabs , brickwork or masonry for all floors above plinth level , and formwork for subsequent floors as per approved design , finishes plastering , flooring tiles , marble , painting , wall cladding , and other interior or exterior finishes , plumbing works , fixing of doors for subsequent floors as per approved design , supply and erection of structural works for cable laying for both incoming and outgoing cables
Tender For supply of air circuit breaker 3 pole, 800 amp, 750v, 50hz cn-cs800c, with 6 no + 6 nc , open air execution thermal magnetic mv voltage release dn1e fixed type manually operated , confirming to rcf specification no edts 103 rev-d, am-7, suitable for use in control panels of rajdhani /shatabdi trains power cars. accepted make : lauritz knudsen electrical automation (formerly l&t), abb & ge as per special repair no. 5 of bom of rcf specification no. edts 103 rev-d, am-4, or any rcf/rdso approved make.
Tender For annual maintenance contract for protection schemes control and relay panels (ashida make) in 25 kv tss/sp/ssp of kurla, panvel & juinagar district of mumbai division for 2 years.
Tender For corrigendum : erection work and dismantling work of 220 kv simplex and duplex control and relay panels of various 220kv bays at 220 kv gss rvpn, sakatpura based on rvpn bsr-2025 )
Tender For auction sale of rolling stock - pl no 98111073 condemned and unserviceable icf bg 8 wheeler ac/non ac coaches no. [1] special repair wgaccn 056118 [2] special repair rs 090259 [3] special repair gslrd 046718 with all available ferrous-non ferrous electrical fittings with wires, fans, lights, switches, mobile chargers, bio tanks, dust bins, wooden items, ss water tanks, aluminium water tanks, porcelain/ss commode/ inlay pans, main doors and lugguage doors, 25kva ac coach under slung inverters and its panels, inverter change over control box, power panel there on and excluding the following reclaimable items. [1] buffer plunger and buffer casing complete set [2] cbc/screw coupling with yoke complete set. rate per number should be quoted advice note no. [1] 012233-25-21552, dt 06.02.26 [2] 012233-25-21556, dt 06.02.26 [3] 012233-25-21554, dt: 06.02.26 approx. weight of the coaches is 75.870 mts. on as is where is condition. note: [1] cutting permitted only for removal of rc items and to cut the coach into two pieces [center cut] if required. [2] crane loading permitted. [3] it is permitted to deliver the coach for which rc items of the coach is being handed over by the purchaser to railways [4] coach in grounded condition without bogie complete set (location: tpgy near satellite depot)
Tender For auction sale of rolling stock - pl no 98111073 condemned and unserviceable icf bg 8 wheeler ac/non ac coaches no. [1] special repair wgaccn 026118 [2] special repair wgaccn 026119 [3] special repair rs 090882 [4] special repair art 906716 with all available ferrous-non ferrous electrical fittings with wires, fans, lights, switches, mobile chargers, bio tanks, dust bins, wooden items, ss water tanks, aluminium water tanks, wall protector, wash basins, ss/porcelain commode/ inlay pans, main doors and lugguage doors, 25kva ac coach under slung inverters and its panels, inverter change over control box, power panel, control panel, there on and excluding the following reclaimable items. [1] buffer plunger and buffer casing complete set [2] cbc/screw coupling with yoke complete set. rate per number should be quoted advice note no. [1] 012233-25-21558, dt 06.02.26 [2] 012233-25-21551, dt 06.02.26 [3] 012233-25-21557, dt: 06.02.26 [4] 012233-25-21553, dt 06.02.26. approx. weight of the coaches is 105.832 mts. on as is where is condition. note: [1] cutting permitted only for removal of rc items and to cut the coach into two pieces [center cut] if required. [2] crane loading permitted. [3] it is permitted to deliver the coach for which rc items of the coach is being handed over by the purchaser to railways [4] coach in grounded condition without bogie complete set (location: tpgy near satellite depot)
Tender For awc for services of anti reptile treatment & rodent control treatment, using paste control method at various panels of unit-ii os 250mw tps parli-v.
Tender For supply, delivery and erection of 60hp open well submersible with control panels and 200mm dia ms pumping main from clear water sump to back wash tank of 85mld water treatment plant at aganampudi in ward no.85 of gvmc. under summer acton plan 2026.
Tender For tggenco btps stage ii em division labour charges for cleaning of outer casing of generators 3 and 4 cleaning of rotor grounding brushes along with brush holders cleaning of exciter chamber cleaning of 72 nos hvr transformers in esps top-up of oil tightening of bolts of power cable at both transformer end and ec panel end tightening of terminals in transformer cabinet filling of silica gel arresting of oil leaks cleaning of sensor processing units cleaning and tightening of panels in esp control room and tightening of ct connections at terminal block in 6.6 kv 3ca 3cb 4ca 4cb occ ocd and ocf boards and all other lt boards for the period from 01.04.2026 to 31.03.2027