Tender For supply of structural audit of building - visual inspection and photography , rebound hammer test , ultrasonic pulse velocity test upv test , cover meter test , half cell potential test , carbonation test , core test , chemical test , vetting of report from approved govt engg college report , report preparing detailed report with stating the
Tender For tender for supply of non-destruction test on concrete members visual inspection visual inspection and photography performing a visual survey of the shed steel structure as per specified in specification of documents , site testing charges concrete upv test ultra sonic pulse velocity test upv test in accordance with is1331 i part i 1992 by portable ultrasonicas per specified in specification of documents , rebound hammer test schmidt s rebound hammer test for determining the concrete compressive test ref is 133 ii part 2 , core test core cutting and compression test for rcc structure in accordance with js 516 on rcc membeers as per specified in specification of documents , profometer scan test on rcc members to assesss covers spacing of bars including approximate diameter bar , half cell potential in accordance with astm c876 half cell potential to assess the probability of corrosion of reinforcement , carbonation in accordance with bs 1881 2011986 clause 2 22 carbonation test to measure extent of carbonation from the concrete surface sac code 998346 , preparing detail report visual inspection and photographs not test results analysis of not data results preparing of drawings strucrural ananysis conclusion and recommendations
Tender For structural audit of building - visual inspection and photography performing a visual survey of the building and recording maping on drawing to assess extent of spelled concrete cracked concrete as per specification of document , ultrasonic pulse velocity test for rcc structure in accordance with is 13311 part 1 1992 by portable ultrasonic non destructive digital testas per specification of document , rebound hammer test rebound hammer test in accordance with is 13311 part 2 1992 by portable rebound hammer equipment at strategic locations , core test core cutting and compression test for rcc structure in accordance with is 516 on rcc members 70 mm core cutting in reinforcement concrete core filling by speialized epoxy material micro concrete with bond coat at strategic locations , reinforcement mapping reinforcement mapping test on rcc members to assess covers spacing of bars including approximate diameter at strategic locations , chemical test for rcc structure in accordance with is 456 2000 using ready made kits and reagents sample collected will be from half cell carbonation powderas per specification of document , half cell potential test for rcc structure in accordance with astm c876 half cell potential to assess the probability of corrosion of reinforcement at strategic locations , carbonation test for rcc structure in accordance with bs 1881 201 1986 clause 2 22 corbonation test to measure extent of carbonation from the concrete surface at strategic locations , to check and confirm present status of structure on basis on ndt results and visual inspection , to provide recommendation for structrue repairs and technical specification preparing bill of quantities for the repair etc all as specified and directed , vetting of report from government engineering college
Tender For supply of polyster staple fibre pillow to size 45x30x10 cms. and weight 400 gms.+/-5% with pr otective cover cloth of 100% cotton mill made superior quality for 2ac & 3ac coaches. constr uction details: material polyster staple fibre, fibre content 100% virgin hollow fibre non comp ressed in the form of sheets. identification of fibre hollowness will be as per is:667/81 (reaffir med 2008) each pillow should be stamped with indian railway logo, manufacturer name, trade m ark, month & year of manufacture in such a fashion that it will not be washed away while repe ated washing. tolerance limit for product size: plus or minus 2% and with following sampling and testing method : 1. sampling plan for visual inspection-is 2500:2000 part 1, gil ii, aql 2.5 2. sa mpling plan for laboratory testing- as per is 745:2003 for sampling purpose only. 3.test requirement and its methods- i) identification of fibre and % composition of filling material as per is:667/1981. ii) identification of fibre and % composition of protective cloth as per is:667/198 1. iii) hollowness of fibre (microscopic examination). . " [ warranty period: 30 months after the date of delivery ]
Tender For supply of structural audit of building - visual inspection and photography , rebound hammer test , ultrasonic pulse velocity test upv test , cover meter test , half cell potential test , carbonation test , core test , chemical test , vetting of report from approved govt engg college report , report preparing detailed report with stating the
Tender For providing of custom bid for services - remote visual inspection jobs rvi insp pan tilt,custom bid for services - remote visual inspection jobs rvi insp crawler