Get complete information related to latest Magnetic Holder Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Magnetic Holder Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Magnetic Holder Tenders.
Tender For supply of cover bolts part no 000110a , isolator assly k3 on off part no 050000 , overload assembly breaker 210a 300a part no 110100c , shunt trip assy 11 point o3 point 00 9 mine line part no 110300 , no volt coil assy 110400 part no 110400 , potential transformer part no ds , incoming gland part no g1 , outgoing gland part no g2 , outgoing gland part no g3 , indicating lamp with pcb mounting part no lab9 , sealing box complete part no s1 , circuit breaker for 100a with complete a part no wr1 , earth leakage relay 50 750 ma 750ma with part no elm7la , core balance transformer part no cbt90m , fixed contact assy 05 point 01 point 00 mine line part no 50100 , moving contact assembly for isolator part no 050200 , shunt trip coils part no 110301 , no volt coilunder voltage coil part no 110402 , catcher assy 11 point 05 point 31 part no 110531 , fixed contact assembly for breaker part no 110600 , arc chutes part no ac1 , ammeter part no am , push button actuator for el test part no boes2 , reset push button contact element part no boes3 , terminal bushing with insulator dmc inco part no t5 , on off isolator 300a part no k4 , circuit breaker for 200a with complete a part no wr2 , complete control wiring including pla r part no wr2a , limit switch no plus nc for breaker part no mcr16d , no volt coil assy under voltage coil as part no 110400a , micro switch part no 50502 , current transformer for ol part no lat3005 , earth leakage relay 50 750ma 2a dual part no elm7dlas , push button with spindle part no pbs , brass terminal with dmc bushing part no t8 , core balance transformer part no cbt150m , busbar part no bbr300 , thermal overload relay part no 120021 , current transformer for ammeter part no 12020055 , potential transformer type d part no ds , overload coil 400a part no 110105 , dashpot cup part no 110106 , flexible copper braids with lugs part no fcs , moving contact assembly for breaker part no 110200 , single phasing preventor with module part no spp5cmsp
Tender For supply of disconnecting and taking out defective under ground lt cable from trenches , supply laying testing and connecting xlpe sheathedpvc insulated screened pvc beddedgalvanised steel strip , all as per boq item no 200 here in before but of size 40 core 16 sqmm complete all as specified , all as per boq item no 200 here in before but of size 35 core 25 sqmm complete all as specified , all as per boq item no 200 here in before but of size 35 core 50 sqmm complete all as specified , all as per boq item no 200 here in before but of size 35 core 70 sqmm complete all as specified , all as per boq item no 200 here in before but of size 35 core 95 sqmm complete all as specified , laying only and connecting xlpe sheathedpvc insulated screened steel strip of wire armoured electric power cable , all as per boq item no 800 hereinbefore but of size 40 core 16 sqmm complete all as specified , all as per boq item no 800 hereinbefore but of size 35 core 25 sqmm complete all as specified , all as per boq item no 800 hereinbefore but of size 35 core 50 sqmm complete all as specified , all as per boq item no 800 hereinbefore but of size 35 core 70 sqmm complete all as specified , excavating in trenches nexc 15 m wide and nexc 15 m depth for foundation etc or for shafts wells cesspits manhole pier hole , returning filling in including spreading levelling watering and well ramming in layers not exc 250mm in soft loose soil complete all as specified and as directed , removing excavated materials soils not exc 5000 mtr and depositing where directed at a level not exc 150 mtr above the starting point in soil complete all as specified and as directed , mandl sand cushioning dry in trenches for protection of ug cables below above and around the ug cable laid in trenches , mandl for fly ash bricks locally available laid dry width wise across the line of cable in trenches for protection of ug cable , supplying and fixing galvanised mild steel pipe tubing light grade complete with all fittings of 80 mm bore dia , supplying and fixing galvanised mild steel pipe tubing light grade complete with all fittings of 50 mm bore dia , supplying and fixing galvanised mild steel pipe tubing light grade complete with all fittings of 100 mm bore dia , m and l for boring of horizontal hole under road pavement hardstanding suitable for passing through up to 80 mm bore , mandl for straight through joint heat shrinkable complete suitable for lt 1100 volt aluminium conductor cable , mandl for straight through joint heat shrinkable complete suitable for lt 1100 volt aluminium conductor cable of size35 4 x 2550 sqmm , mandl for straight through joint heat shrinkable complete suitable for lt 1100 volt aluminium conductor cable of size35 x 70150 sqmm , supplying and fixing high density polyethylene pipes hdpe of pressure rating 6 kgf cm2 complete with all fittings of 25 mm bore dia , supplying and fixing high density polyethylene pipes hdpe of pressure rating 6 kgf cm2 complete with all fittings of 40 mm bore dia , supplying and fixing high density polyethylene pipes hdpe of pressure rating 6 kgf cm2 complete with all fittings of 50 mm bore dia , supplying and fixing high density polyethylene pipes hdpe of pressure rating 6 kgf cm2 complete with all fittings of 100 mm bore dia , material and labour for earthing complete with galvanised steel earth plate electrode 600x600x6 mm mm buried directly in ground , dismantling existing lt panels of any type any size carefully for reuse including necessary excavation demolition of concrete , labour only for disconnecting isolating and taking out burned unserviceable lugs switchgear metering devices wiring bus bar etc , supply only the followings to be incorporated against item no 3000 and 3100 only 06 sqmm to 16 sqmm , 25 sqmm to 50 sqmm , 70 sqmm to 95 sqmm , 120 sqmm to 240 sqmm , epoxy type insulator upto 1100volt for lt panel bus bar including nut bolts etc complete all as specified and as directed , single core stranded copper c
Tender For supply of disconnecting and taking out defective under ground lt cable from trenches pole pipe floor wall etc , supply laying testing and connecting xlpe sheathed pvc insulated screened pvc bedded galvanised steel strip of wire armoured electric power cable heavy duty , all as per boq item no 2.00 here in before but of size 4.0 core 16 sqmm. complete all as specified , all as per boq item no 2.00 here in before but of size 3.5 core 25 sqmm. complete all as specified , all as per boq item no 2.00 here in before but of size 3.5 core 50 sqmm. complete all as specified , all as per boq item no 2.00 here in before but of size 3.5 core 70 sqmm. complete all as specified , all as per boq item no 2.00 here in before but of size 3.5 core 95 sqmm. complete all as specified , laying only and connecting xlpe sheathed pvc insulated screened steel strip of wire armoured aluminium conductor 1100 volt grade of size 4 core 10 sqmm , all as per boq item no 8.00 here in before but of size 4.0 core 16 sqmm. complete all as specified , all as per boq item no 8.00 here in before but of size 3.5 core 25 sqmm. complete all as specified , all as per boq item no 8.00 here in before but of size 3.5 core 50 sqmm. complete all as specified , all as per boq item no 8.00 here in before but of size 3.5 core 70 sqmm. complete all as specified , excavating in trenches n.exc 1.5 m wide and n.exc 1.5 m depth for foundation etc or for shafts wells cesspits manhole pier hole taking out and laying of cable etc n.exc 10 sqm , returning filling in including spreading levelling watering and well ramming in layers not exc. 250mm in soft loose soil complete all as specified and as directed. , removing excavated materials soils not exc. 50.00 mtr and depositing where directed at a level not exc. 1.50 mtr above the starting point in soil complete all as specified and as directed. , m and l sand cushioning dry in trenches for protec tion of ug cables below above and around the ug cable laid in trenches of 230mm spread thickness , m and l for fly ash bricks locally available laid dry width wise across the line of cable in trenches for protection of ug cable complete all as specified and as directed. , taking down unsv gi hdpe pipe , s and fix 50 mm hdpe pipe of 6kgf c3 complete , supplying and fixing galvanised mild steel pipe tubing light grade complete with all fittings of 80 mm bore dia , supplying and fixing galvanised mild steel pipe tubing light grade complete with all fittings of 50 mm bore dia , supplying and fixing galvanised mild steel pipe tubing light grade complete with all fittings of 100 mm bore dia , m and l for boring of horizontal hole under road pavement hardstanding suitable for passing through up to 80 mm bore , m and l for straight through joint heat shrinkable complete suitable for lt 1100 volt aluminium conductor cable of size3.5 4 x 10 16sqmm , m and l for straight through joint heat shrinkable complete suitable for lt 1100 volt aluminium conductor cable of size3.5 4 x 25 50sqmm , m and l for straight through joint heat shrinkable complete suitable for lt 1100 volt aluminium conductor cable of size3.5 x 70 150sqmm , supplying and fixing high density polyethylene pipes hdpe of pressure rating 6 kgf cm2 complete with all fittings of 25 mm bore dia , supplying and fixing high density polyethylene pipes hdpe of pressure rating 6 kgf cm2 , supplying and fixing high density polyethylene pipes hdpe of pressure rating 6 kgf cm2 complete with all fittings of 50 mm bore dia , supplying and fixing high density polyethylene pipes hdpe of pressure rating 6 kgf , material and labour for earthing complete with galvanised steel earth plate electrode 600x600x6 mm , dismantling existing lt panels of any type any size carefully for reuse including necessary excavation demolition of concrete , labour only for disconnecting isolating and taking out burned unserviceable lugs switchgear metering devices wiring , 06 sqmm to 16 sqmm , 25 sqmm to 50 sqmm , 70 sqmm to 95 sqmm
Tender For corrigendum : supply of electrical terminals as per is 8309 (q3) , piano type modular domestic electrical sockets - is 1293 (q3) , piano type non modular domestic fan regulator as per is 11037 (q3) , non - modular piano type domestic electrical switches as per is 3854 (q3) , piano type non modular electrical switch socket combination as per is 3854 and is 1293 (q3) , elecric bells and accessories as per is 2268 (q3) , electrical plugs (v2) isi marked to is 1293 (q2) , led recessed mounting slim panel 600x600mm 36 w , led street light driver 72 watt , led street light driver 90 watt , led street light driver 120 watt , led recessed mounting fitting 18 watts square , led drivers 40 or 45 watt , led recessed mounting fitting 12 watts square slim , copper hd lugs 120 sqmm , heating element 2000watts , heating element 1500watts , condensor 2 point 5 mfd for ceiling fan , distribution box 4 way spn double door ip 43 , distribution box 8 way spn double door ip 43 , energy meter tp ct operated , energy meter sp 10 to 40 amps , thermostat geyser , pendent holder pvc , lamp holder angular type , pvc casing caping 25mm or 1 inch length 2mtr , pvc casing caping 20mm length 2mtr , insulation tape 25mm , modular ac starter , calcium hypochlorite altoch gp make altoch , aluminium door stopper 100mm long with leg , aluminium door stopper 150mm long with leg , gasket rubber for door 2mm thick and 50 mm wide , teflon tape 19mm width , tank cover pvc for 500 and 1000 ltr capacity with fixing arrangement bid number/ & ( * ) : gem/2025/b/6020904 dated/ + : 10-03-2025 bid document/ 3 3 1 / 35
Tender For corrigendum : enquiry for supply of carbon brushes, grade gh-125 for unit no.1,2,4 and 5 at gandhisagar hps mppgcl,gandhisagar-slip ring carbon brush for unit no.1,2 (grade gh-125),size(lxwxt), size 43mm x 40mm x 16mm length of lead withlugs 115 mm, u type 10 mm gapnos20002 main exciter carbon brush for unit no.4&5(grade gh-125) size(lxwxt) 42 x 25 x 16mm with rubber insulated double flexiblelead length 115mm with u type lugs 10mm gapnos25003 slip ring carbon brush for unit no.4&5 (grade gh-125), size 50mm x 30mm x 30mm,length of lead with lugs 165mm, utype 13mm gapnos 10004 pilot exciter carbon brush for unit no.4&5,(grade gh-125) size(lxwxt) 33 x 15 x 10mm with rubber insulated flexible leadlength 115mm with u type lugs 6mm gap
Tender For 1)supply of two nos. of out door type 750kva, 11kv/400v, onan auxiliary transformer along with oil as per site requirement 2)supply of lt copper power cable 400v, 1.1kv grade pvc armored 3.5 core 2rx 400 sqmmm along with lv cable termination accessories,lugs etc 3)dismantling of existing 2 nos. of 750kva auxiliary transformers and old oil cooled cables at ltac panel and auxiliary transformer end and its accessories 4) laying of lt copper power cables and termination of cables along with supply of all accessories for laying of cables 5)erection, cabling, testing and commissioning of 2 nos. of 750kva,11kv/400v auxiliary transformers 6)buy back of released two nos. of 750kva auxiliary transformers along with oil