Tender For providing of custom bid for services - ultrasonic thickness survey of above ground ng pipeline for qty 50000 ea refer scc and sow,custom bid for services - ultrasonic thickness survey of underground ng pipeline for qty 70 mad refer scc and sow,custom bid for services - ultrasonic flaw detection (ufd) of ng pipeline for qty 50 mad refer scc and sow,custom bid for services - phased array ultrasonic testing for qty 40 mad refer scc and sow,custom bid for services - time of flight diffraction (tofd) assessment for qty 20 mad refer scc and sow,custom bid for services - dye penetration test for qty 120 mad refer scc and sow,custom bid for services - magneticparticletesting for qty 60 mad refer scc and sow,custom bid for services - radiography for nps=<6 inch for qty 60 id refer scc and sow,custom bid for services - radiography for nps>6 inch for qty 360 id refer scc and sow,custom bid for services - pulse eddy current testing for qty 20 mad refer scc and sow,custom bid for services - mobilization and demobilization charges
Tender For supply of welding machines w1 c c - transformer welding set 300 amps , d. c arc welding rectifiers , welding transformer or inverter based welding machine , welding transformer with all accessories , portable gas cutting machine capable of cutting , gmaw welding machine 400amp , ac and dc gtaw welding machine with water cooled torch , air plasma cutting equipment with all accessories , spot welding machine to 15 kva , magneticparticletesting kit , water cooled induction welding and brazing machine 200 to 250 amp , plastic welding machine with hot air gun , multi angle magnetic clamp set metal base , co 2 welding machine complete set , tig welding
Tender For magneticparticletesting (mpt) of cbc knuckle during roh of wagons at wagon care centre ntsk and ss-i of lhb coaches at coaching depot dbrg and coaching depot tsk for a period of 02 years.
Tender For supply of permanent magnetic yoke (rope type) to carryout magneticparticletesting (wet and dry method) as per. is: 3703/2004.the technical specification is given below; 1) lifting power : 20kg or more with pole spacing 100mm.2)magnetic field: constant level.3)poles adjustment : 0-300mm. 4)tangential field strength :minimum value of 30g.5)equipment weighs not more than 400grams.
Tender For provisioning of electrical and mechanical eqpt against ber under ge 862 ews - supply, installation, testing and commissioning of serve controlled voltage stabilizer (confirming to bis 9815 (part-1) 1994, reaffirmation 2019 latest version) three phase, four wire (rybn), 50 hz, naturally oil cooled, outdoor, unbalanced type, cooper wound, metallic body duly power coated with lifting hooks two nos, digital display type, relay free smooth and silent operation with 1st filling of transformer oil up to level having following specification:-(a) capacity 300 kva (b) type - suitable for unbalanced load and unbalanced input(c) input voltage -360v-480v, input frequency 50 hz (d) output voltage - stabilized at any deigned/ desired voltage 415/+-1% (e) rated frequency - 50 hz(f) wave form distortion - nil (g) response time - not to exceed 20 milli seconds(h) sensitivity - (+/-) 1% (j) rate of correction - not less than 6 volt/second between phase and neutral (k) efficiency - more than 95% (l) type of load - three phase, unbalanced type(m) metering - digital display voltmeter/ammeter with multi-functional meter (n) operating temperature - for indoor use upto max ambient temp + 55 c (o) dimmer rating - 450 amp (p) dimension of tanks - as per oem design(q) oil capacity- as per oem design , (r) class of insulation - class f (s) mode of operation automatic/manual (t) winding temperature rise - max 55 c (10 c above operating temp) (u) transformer oil -is 335 marked (v) core-crgo m4 grade/crno (cold roll grain oriented)/ (cold rolled non-oriented)(w) auto transformer (variac) -100 percent copper wound electrolytic grade(x) losses - as per is norms (y) power factor - not less than 0.95(z ) protection - (i) over load protections (ii) short circuit protections (iii) high/low voltage cut off (iv) by pass arrangement in case of emergency (v) single phase sequence change /phase fail protection (vi) earth fault protection(aa) standard fitting & accessories e.g marking plate, lifting lugs, ci rollers, earthing terminals, cable box including suitable platform as reqd on site complete all as as specified & directed., supply, installation, testing and commissioning of serve controlled voltage stabilizer (confirming to bis 9815 (part-1) 1994, reaffirmation 2019 latest version) three phase, four wire (rybn), 50 hz, naturally oil cooled, outdoor, unbalanced type, cooper wound, metallic body duly power coated with lifting hooks two nos, digital display type, relay free smooth and silent operation with 1st filling of transformer oil up to level having following specification:-(a) capacity 100 kva (b) type - suitable for unbalanced load and unbalanced input(c) input voltage -360v-480v, input frequency 50 hz (d) output voltage - stabilized at any deigned/ desired voltage 415/+-1% (e) rated frequency - 50 hz(f) wave form distortion - nil (g) response time - not to exceed 20 milli seconds(h) sensitivity - (+/-) 1% (j) rate of correction - not less than 6 volt/second between phase and neutral (k) efficiency - more than 95% (l) type of load - three phase, unbalanced type (m) metering - digital display voltmeter/ammeter with multi-functional meter (n) operating temperature - for indoor use upto max ambient temp + 55 c (o) dimmer rating - 150 amp (p) dimension of tanks - as per oem design(q) oil capacity- as per oem design , (r) class of insulation - class f (s) mode of operation automatic/manual (t) winding temperature rise - max 55 c (10 c above operating temp) (u) transformer oil -is 335 marked (v) core-crgo m4 grade/crno (cold roll grain oriented)/ (cold rolled non-oriented)(w) auto transformer (variac) -100 percent copper wound electrolytic grade(x) losses - as per is norms (y) power factor - not less than 0.95(z ) protection - (i) over load protections (ii) short circuit protections (iii) high/low voltage cut off (iv) by pass arrangement in case of emergency (v) single phase sequence change /phase fail protection (vi) earth fault protection(aa) standard fi