Get complete information related to latest Mast Light Pole Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Mast Light Pole Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Mast Light Pole Tenders.
Tender For supplying electrical materials and repair maintenance services at. grampanchayat nighoje tal khed dist pune - supplying and erecting modulartype switch6a / 10a, supplying and erecting street light bracket for erection ofsingle fitting made from 40 mm. dia b class g.i. pipe 1.0 m in length, providing cement concrete foundation including excavationfor the poles 60 cm x 60 cm x 1.5 m deep in 1:3:6 cement concrete (20 x 25 mm stone metal) and 45 cm x 45 cm x 45 cm/45 cm dia. x 45 cm height plinth duly plastered and with necessary curing and finishing in an approved manner.(for 8.5 to 9 m poles) (16-3-2), supplying and erecting steel tubular swaged pole 139.7 x 114.3 x 88.9 mm. dia with 4.5x3.65x3.25 mm thickness (4.5 + 1.75 + 1.75m) length respectively and total 8 m long with pole cap, base plate in provided foundation.(weight 101 kg.) as per specification no.oh-pl/stp, supplying and erecting street light bracket made from 25mm. dia b class g.i. pipe, 0.6m. in, supplying and erectingled street light fitting suitable for 36w to 40w led street light, including lamp, with pf > 0.95 class ip 65 ., supplying and erecting led street light fitting suitable for 50w lamp, including lamp, with pf > 0.95 class ip 65., supplying and erecting led street light fitting suitable for 60w lamp, including lamp, with pf > 0.95 class ip 65., supplying and erectingled street light fitting suitable for 90 w led street light, including lamp, with pf > 0.95 class ip 65., supplying and erecting led flood light fitting of 120w, including lamp, with pf > 0.95,class ip 65, supplying and erecting led flood light fitting of 150w, including lamp, with pf > 0.95,class ip 65, providing rental basis hydraulic bucket vehicle of hight 13 mtr. and weight capacity 200 kg. with driver, oprator and disel etc. for per day basis, providing rental basis hydraulic bucket vehicle of hight 13 mtr. and weight capacity 200 kg. with driver, oprator and disel etc. for per day basis, labour chrages for led fitting on street light or ms lightpole., dismentaling charges -led street light of pole., 1.25 mm crca sheet metal enclosures box for timmer and mcb, supplying pvc insulated pvc round sheathed 1.5 sq.mm, supplying & laying armoured cable 4c x 6 sq.mm., supplying & laying armoured cable 4c x10 sq mm, supplying & laying armoured cable 2c x 10 sq mm, supplying & laying armoured cable 4c x 16 sq mm, supplying, erecting & marking spmcb 6a to 32a, b- series (for lighting) 5-3-3, supplying, erecting & marking dpmcb 6 a to 32 a bseries (for lighting) 5-3-7, supplying and erecting programmable digital almanactimer microcontroller based with real time clock to operate on derived switching on & switching off street light as per daily sunset and sunrise respectively, supplying & erecting crimping type aluminium lugs for cable upto 16 sq mm complete, supplying & erecting crimping type coper lugs for cable upto 1.5 to 6sq mm complete , supplying and erecting two pole power contactor 250v 32a for time switch complete erected on wooden block/provided box, with necessary materials. 4-4-3, supplying & erecting mains with2x1.5 sq.mm f.r copperpvc insulated wire laid in provided conduit/trunking/inside pole., supplying and erecting mains with isi mark wp2 x 6 sq. mm. 1100 v. grade aluminium pvc insulated pvc sheathed wires on g.i. bearer wire no. 8 swg 1-4-3, supplying and erecting mains with isi mark wp2 x 2.5 sq mm. 1100 v. grade aluminium pvc insulated pvc sheathed wires on g.i. bearer wire, supplying and erecting mains with isi mark wp2 x 10.00 sq mm. 1100 v. grade aluminium pvc insulated pvc sheathed wires on g.i. bearer wire, 25 amp, 32 amp three phase l/t contactor, 2.5 sq. mm multistand copper wire, insulation tape, water proof tape, street lightpole box frp, cement street lightpole clamp, m.s. street lightpole clamp, led street light arm bend pipe, small size frp box for mcb, big size frp box for mcb, supplying and laying (including excavation of
Tender For provision of 2 nos. 12 mtr. semi high mastlightpoles with led lights at new ashok nagar nala road in ward no 190 new ashok nagar under shahdara south zone
Tender For repair maintenance of electrical and mechanical services at delhi vidhan sabha, old sectt., delhi. (sh - repairing / replacement decorative tringa pole / other led fixtures).
Tender For tender for supply of taking down of light fittings of any type size and model complete all as specified and directed. , taking down of brackets of any type size and model complete all as specified and directed. , m& l in repair steel tubular swaged poles complete with cast iron base plate , finial taper plug , bolts , nuts & screws as specified type 410 sp 22 (8.5 metres long) complete all as specified & directed. , m& l in repair steel tubular swaged poles complete with cast iron base plate , finial taper plug , bolts , nuts & screws as specified type 410 sp 31 (9 metres long) complete all as specified & directed. , re fixing of led street light fittings of any wattage outdoor type complete all as specified and directed. , supply and fixing in repair led street light fitting 120 watt 230 v ac outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver , lamp bracket with impact and corrosion resistant including thermal management in multiple optics , efficacy 110/120 lpw , complete with ip 65/66 protection complete all as specified and directed. , supply and fixing in repair led flood light 80 watt 230 v ac outdoor type with thermal management in multiple optics and equipped with ip66 protection , with impact and corrosion resistant complete with driver and lamp , efficacy 110/120 lpw , including clamp , nut , bolts etc.complete all as specified and directed.make. crompton , cat no.lfl 80 cdl/60 hpm , supply and fixing in repair led flood light 150 watt 230 v ac outdoor type with thermal management in multiple optics and equipped with ip66 protection , with impact and corrosion resistant complete with driver and lamp , efficacy 110/120 lpw , including clamp , nut , bolts etc.complete all as specified and directed.make. crompton , cat no.lfln 150 cdl/60 m , s&f cable junction box 155x210x92 mm in size , made out of thermoplastic , having ip 66 protection for outdoor installation fixed with 4 way bakelite cable terminals including 03 nos polymide gland with check nut (m 32 02 no & m 25 01 no) fixed on poles with aluminium clamps of size 25x3mm , nuts , bolts , washers etc. including taking out of old unserviceable cable junction box complete all as specified and as directed. make. cat no. dk 1616g of hensel or equivalent model , supply and passing through steel tubler pole/service connection , 1100 volts grade multicore , fr , round insulated copper conductor and sheathed flexible cable , multistranded , three core of nominal cross sectonal area 1.5 sq mm , for connection of security light from junction box through pole /conduit with all terminals complete all as specified and as directed. , s and f single arm bracket made of40mm dia 1.0mtrs long for security light , with mounting ms clamp of flat iron size 25x5mm of suitable length 02 pairs including nut bolt etc of suitable size and painting to ms clamp with two coats of aluminium paints over a coat of red oxide netal primer all as specified and directed by engr in charge. , s & f in repair rigid non metallic pvc conduit of dia 20 mm exclusive of boxes (junction/terminal) but inclusive of all tees , bends , elbows , reducers , bell mouth tube ends and fixing accessories such as couplers , lock nuts , saddles , pipe hooks , clamps etc. all as specified and directed by engr in charge. , m and l for earthing complete with ms galvanised plate of size 60cmx60cmx6mm as earth electrode buried directly in ground earth pit not less tan 2.25mtrs deep below ground level with top edge of the plate not less tan 1.5mtrs below normal ground level connected to galvaniosed iron strip 32x6mm as earthing lead by means of bolts nut check nut and washers of galvanised iron welding or steel all as shown in electrical plate no 3 in ssr part i of 2009 connected to earthing test point all as specified complete with exevation and earth work pcc pit with 6mm thick ci ms cover having suitable handle 10mm ms rod with frame and locki