Tender For welcome maintanance of internal electrificatin work including point wiring submain wiring mcbs dbs electrical fitting including earthing at md accn at shakurbasti and hirankudna military station under ge north delhi cantt10
Tender For development of warehouse for storage of histopathology cytopathology slides and blocks patient records forms at jhajjar campus of aiims new delhi sh comprehensive consultancy services for civil, electrical and ac and r work planning for warehouse which including preparation of architectural structural all external internal services hvac electrical plumbing landscaping fire alarm and firefighting lan wiring design any drawing details estimation nit site supervision preparing of bills etc till completion of work
Tender For supply of demolish of old ceiling,gypsum fall ceiling work,screen for windows,window roller blinds,electrical wiring,ceiling color work,wall colouring,22w ceiling light,led striplight fixing,ceiling fan,wall fan
Tender For work of renewal and replacement of damaged and leaking roof paintwork joinery electrical wiring water supply sanitary and other allied civil works at me division pspcl amritsar
Tender For work of providing electrical repairing material for led lights installed in the municipal area. - providing & laying p.v.c. / xlpe insulated & p.v.c. sheathed un-arrmoured aluminium cable confirming to is:1554 p-i/is:7098 p-1 of 1.1 kv with h4- grade electrolytic aluminium conductor confirming to is 8130 of purity >99.6%, inner / outer sheath confirming to is:5831 in existing rcc/hume/stoneware / pvc pipe/open duct/cable trench / cable tray (with cable tie) including testing etc. as required of following size. oem must have it's own in house nabl accrediated laboratory for testing procedure as per is:10810. for additional technical parameters of product / work refer annexure 'a' attached with this bsr 1 6x 2 sq. mm. (insulated) , providing & fixing of 240/415 v ac mcb with positive isolation ka breaking capacity (b/c/d tripping characteristic as load and site requirement) 4 kv impulse withstand voltage, isi marked is 8828(1996)/conforming to iec 60898-1 2002, iec 60947-2, low watt losses, trip free mechanisum, energy limiting of class 3 as per iec, minimum phase termination capacity of 35sq.mm., conductor line load reversibility, ip 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 a rating and 10,000 upto 63 a, 5000 for 80 a & above rating including making connections, testing etc. as required. oem shall have submit nabl/cpri / erda accrediated lab type test reports & all as per pre approved by engineer in 0.5 a to 5 a ratin , double pole mcb(with b/c curve tripping characteristics) , four pole mcb (with b/c curve tripping characteristics) , supplying and fixing of aluminium (iec 60105 iso 209-1,2) / copper (iec 60028) bus bar by means of smc / dmc type insulator with standard short circuit withstand capacity, high tensile nuts and bolts spring washers in existing panel including bending, cutting in required shape and size and colour coding with heat shrinkable pvc sleeves. all as per pre approved by engineer in-charge. for additional technical parameters of products/work, refer annexure "a" attached with this bsr. , main panel street light control panel commissioning kiosk type weathe proof panel out door main cubic panel size 750x1250x500 they shall be in two section comaring as follows bsr 2017 (59.57) , supply & drawing wiring for sub mains isi marked (is:694) 110volts grade pvc insulated flat twin core sheathed solid aluminium 4 sq mm 2 core flat
Tender For the detail of works includes:a. the tenderer shall carryout the following works during annual maintenance contract period along with the servicing of the diesel generator set.1. general checkup & preventive maintenance and to fill up preventive checkup schedule as follows:a) check lube oil level and conditioning of lube oil, top up/refill if required.b) the oil filters shall be replaced whenever oil is changed.c) the air filters shall be cleaned periodically with compressed air, check batteries and top up the distilled water if required.d) check functioning of changing alternator.e) engine safety viz. high water temperature gauge, oil temperature gauge and high speed gauge shall be checked for their functions and repaired/replaced if required.f) coolant level and conditioning of coolant shall be checked and refilled if required.g) check fan and alternator drive belts and tightened if required.h) the governor shall be checked and tuned for proper functioning.i) check for leaks if any and shall be rectified.j) check reports shall be submitted every month/every breakdown calls.2. checking and servicing of engine for smooth running, its unusual sound and color of smoke and exhaust and set it right in case of deviations.3. checking and repairing and leakage of fuel, lubricating oil and coolant.4. cleaning and changing of air filters as per requirement.5. setting of valves tappets whenever required.6. checking and repairing of accessories drive, turbo charger and crankshaft endplay whenever required.7. checking of alignment of engine & alternator as per requirement.8. checking of throttle control and its setting.9. checking of instrument panel including replacement as and when required.10. checking of rotating diodes assembly in brushless alternator including replacement as and when required.11. checking of wiring system and repairing/replacement as and when required.12. repair and maintenance of relays including contractors in control panel.13. checking of battery terminal and de-sulphating.14. diagnosis of faults in engine and alternator and its rectification.15. breakdown calls to be attended on priority within 6 hrs.16. providing spare avrs, self-starter and accessories, free of charge, if the repair/overhaul/replacement is expected to be taken in more than two days.17. checking/repair/adjustment/replacement/servicing shall be carried under annual maintenance contract except cost of component/parts to be replaced due to wear & tear.18. the firm should undertake to arrange genuine spares of the diesel engine, alternator and amf panel as and when required within two working days.19. the tenderer’s service engineer shall visit the site for attending the generator sets not less than twelve times during the contract period (minimum once in a month) and shall inspect the generator set thoroughly. each visit shall take place during 1st week of each month.20. the tenderer’s service engineer shall visit once in two month for checking of electrical side viz. alternator, amf control panel, if any.21. the engine shall be run on no load or at available load, and should be checked for any leakage and abnormal noise. if any such abnormality noticed shall be diagnosed and remedial action shall be taken.22. standard check list:a) replace minor parts (i.e hoses and filters etc) sub-assemblies as and when required.b) service engineers during the visit will report on the performance or any other abnormality and inform parts requirement. he shall also submit the report on work done and recommendations as well as spare parts required.c) attend emergency call on priority (usually same day). however, if the engineer is required or any particular date and time, it would be the responsibility of the customer to intimate the contractor in advance.d) major overhauling/ top overhauling / pt pump & injector calibration /replacement of major parts/ rewinding of alternator or repairs or breakdown of the diesel generator set are to be charge
Tender For work contract for providing desert coolers (jumbo size 5 feet height) to power transformer with installations (inc. electrical wiring) at 33/11 kv substations under dhule usd_i sub-division, deopur sub-division, cco&m sub-division, naradana sub-division for the period two months
Tender For bid to ras corrigendum : tender for supply of design and engineering of imcc panel 2 nos and vfds and plc network , design and engineering of apfc and hvac , design and engineering of apfc and field instruments , design and engineering of cables and termination and airconditioning for imcc building , design and engineering of earthing of imcc , field equipments and soil testing , design and engineering of civil buildings and structure foundations , design and engineering of imcc building with earthing system , design and engineering of structural works for cable laying for both incoming and outgoing cables , design and engineering of lighting system of imcc building , equipment locations at ccr ground floor and along the structural path for cable route , design of fire detection and alarm system for building and cable alley area along with integration and display at fire station/existing control centre , supply of imcc panels , vfd panels , supply of apfc panels , hvac system/ air conditioning systems for imcc building and other area air conditioners as mentioned in scope of work , supply of mldb , lighting distribution boards , lighting material including db , light fittings , and all related accessories or wiring material and other electrics etc , supply of field instruments and necessary piping materials as required , supply of plc and other related required accessories , supply of lt cables and other related accessories for electrical , termination material and other instrumentation cables etc and other related electrics as required , supply of cable trays for electrical and instrumentation , supply of all earthing material as per is 3043 for imcc and connection to earth pits for motors , panels etc , supply of fire detection and alarm system for building and cable alley area along with integration and display at fire station/existing control centre , erection , testing , commissioning , and handover of equipments of imcc panels and vfd panels , erection , testing , commissioning , and handover of equipments of apfc panels and hvac system , erection , testing , commissioning , and handover of equipments of lighting system as per above supply , erection , testing , commissioning of earthing system , erection , testing , commissioning of field instruments and necessary piping materials etc as required , erection , testing , commissioning and handover of plc , erection , laying , testing and commissioning of lt cables cable terminations wherever required along with necessary accessories is in the scope of the contractor for electrical and instrumentation , erection , testing and commissioning of cable trays for electrical and instrumentation , erection , testing and commissioning of fire detection and alarm system for building and cable alley area along with integration and display at fire station or existing control centre , substructure excavation , foundation works footings , columns up to plinth level , dpc damp proof course , and backfilling. , superstructure columns , beams , slabs , brickwork or masonry for all floors above plinth level , and formwork up to ground floor , finishes plastering , flooring tiles , marble , painting , wall cladding , and other interior or exterior finishes , plumbing works , fixing of doors up to ground floor. , superstructure columns , beams , slabs , brickwork or masonry for all floors above plinth level , and formwork for subsequent floors as per approved design , finishes plastering , flooring tiles , marble , painting , wall cladding , and other interior or exterior finishes , plumbing works , fixing of doors for subsequent floors as per approved design , supply and erection of structural works for cable laying for both incoming and outgoing cables