Get complete information related to latest Mcb Board Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Mcb Board Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Mcb Board Tenders.
Tender For repairs maint of ht lt electric system transformers vcb ht lt panel ht lt under ground over head cables apfc panel and certain allied works at certain locations at r and de e dighi pune
Tender For repairing the ht outgoing cable of vcb (tr-1) and servicing the ht/ lt panels, switchgear installed dse substation and repairing the amf panel of diesel generator set at fms etc. at university of delhi
Tender For supply of routine electrical maintenance of depot , transformer oil testing , installation of acb spares , srvc f inspection and pm of acbs , servicing overhauling and testing f vcb , thermography testing of panel , sply instln lightning arrestor , earthing wire cu 6mm2 , sply and fixg of fuse element rating 11k , earthing clamp , calibration of meter , testing calibration of relay , repair of boom barrier , repair and maint of water pump , testing and servicing pv vent 3in , maint and insp tsvtest and re inst half yrly , sply of 33 kv rubber hand gloves isi app , 11kv rubber hand gloves , silica gel , distilled water battery litres , testing of transformer tan delta , rewinding of motor pump overhauling , electrical insulation mat 2 point 5 mm thick , pvc tape steel grip , crc spray cap 200ml , sply and instln of contactor rat 32a , elcb 30 ma 63 a legrand rating 415v 0 point 0 , elcb 32a 30ma dp w 2nosauxtrpcntct , mcb 415vac 32a 10ka 3p c iec60898 1 , mcb 415vac 63a 10ka 3p c iec60898 1 , hrc fuses for diodes 50a , sply and instln of contactor rat 70a , trip shunt coil acb 110vdc land t , braided wire cu 6mm2 , braided wire strip cu 1in , itc of lugs for 16 sqmm cu , lug ring cu 25mm2 , lamp led indctng 60w rd ylw bl hghmst cg , sup led driver 60w , racking mechanism up acb l and t upower , closing coil shnt trp 110vdc acb 800a , extl safety auditdepot terminal plant , sup and fix of crocodile cliphvydty f earth , contactor dc 110vdc 100a 3p btry chrgr , earthing strip size 50x60x6mm , testing of ht cable meggering and continuity , testing of lt cable meggering and continuity , partial disch testing of cable ht and lt , sply and instln of 2way flp jbtestg and comm , vlf testing of cable , earthing funnel gi , ss nut bolt 1 inch , sup and lay wbmstone aggregate 90 45mm , testing ir and motor tmnl conn yearly , preparation drawingloop diagram layout , autocad drawing retracinglayout conversi bid details/ 2 / 47
Tender For supply, installation, testing and commissioning of single panel ht 11kv/0.433kv vcb (01 inc oming and 01 outgoing) 630amp as per is and specification attached. [ warranty period: 30 months afte r the date of delivery ]
Tender For corrigendum : for running contract for hon,ble sansad nidhi/vidhayak nidhi and other deposit works under edd-budaun (semi turnkey). - cartage of following material from store center nawada, budaun to je store/je store to site of work including loading & unloading at both ends maximum distance up to 30 km., a) pcc pole 8.5 mrt long/st pole 11 mtr long., b) 11 kv xlpe cable of 3x70/3x120/3x185/3x300 sq.mm., c) 250/400 kva t/f., d) 11 kv ct/pt unit of different size, e) 11 kv jointing kit of different size, f) 11 kv pilfer proof cubical of different size, g) lt abc cable of size 1x16, 3x50, 3x95, 3x120 sq.mm., cartage of line material (11 kv pin insulator, disc insulator, stay set, cross arm, gi wire, earthing rod, ms channel, ms angle, etc) from store centre to dump site & then dump site to site of work on day to day basis, including loading & unloading at both ends maximum distance up to 30 km., cartage of 10 kva & 25 kva transformer from store centre to site of work including loading & unloading at both site, the work of safe carriage 11 kv o/g vcb store center nawada budaun to work of site distance up to 0 to 30 km including safe loading & unloading., cartage of 63 kva to 100 kva transformer from store centre to site of work including loading & unloading at both site., earthing of each 11 kv line pole & t/f properly after drive of electrodes if size 20mmx250mm and connection the earthing point with gi wire., erection of pcc pole 8.5 mtr long after digging a pit of size 1.20 x 0.60 x 1.6 mtr in all type of soil including back filling of the pole with proper ramming after completion of work., erection of stp pole 11 mrt long after digging a pit of size 1.20 x 0.60 x 1.6 mtr in all type of soil including back filling of the pole with proper ramming after completion of work., fabrication and fixing of all 11 kv h.t/l.t. line accessories., erection of double pole on pcc pole 8.5 mtr/stp 11 mtr. long after digging of pit of required size including fabrication and fixing of top channel, droper channel & base channel alongwith, fixing all 11 kv accessories, fuse set 11 kv pin insulators and making connection properly., construction of new plinth for 250/400 kva as per uppcl norms, mounting of 250/400 kva t/f on plinth as per uppcl norms, providing and fixing wiremess fencing for 250/400 kva, erection/installation of following of vcb o/g in consumers site and cable joint of the panel to including earthing, grouting, anchor bolt of panel of making/repairing of pocket for cable to insert in panel form trench and fixing taping of busbar with wiring for ac,dc connection including providing ac and dc supply., chemical earthing for 250/400 kva t/f neutral and body complete, chemical earthing for vcb o/g, mounting of 10 & 25 kva t/f with proper jumping of ht side and fixing of cable on lt. side of t/f making connection properly., mounting of 63 & 100 kva t/f with proper jumping of ht side and fixing of cable on lt. side of t/f making connection properly., mounting of ct/pt unit with proper jumping of ht side and fixing of cable on lt. side of meter cubical properly, fixing of meter cubical as per uppcl norms, making a section pole to exist pole after fabrication & fixing of t channel fixing of all 11 kv accessories., erection of stay rod complete after digging a pit of size 1.20 x 0.60 x 1.6 mtr and grouting the same in block of size 0.60 x 0.60 x 0.30 mtr and nuzzling at the both ends and filling the pit with excavated earth soil with proper ramming., laying lifting stringing of proper sagging of acsr weasel/rabbit/dog conductor for 3 phase, 3 wire 11 kv line including binding & jumpering properly., laying lifting stringing of proper sagging of 11 kv xlpe cable of 3x70, 3x120, 3x185, 3x300 sq.mm., laying of underground 11 kv xlpe cable of 3x70, 3x120, 3x185, 3x300 sq.mm. sizes with open trench by brick & sand as per uppcl norms., filling the 11 kv jointing kit (joint kit providing by c