Web Analytics Made Easy - StatCounter

Mechanical Power Transmission Equipment Tenders

Get complete information related to latest Mechanical Power Transmission Equipment Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Mechanical Power Transmission Equipment Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Mechanical Power Transmission Equipment Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government And Public Sector

CTN :38587336 Due date: 28 Dec, 202428 Dec, 2024 8.22 Lacs
Tender For customized annual maintenance contract (amc) / comprehensive maintenance contract (cmc) for pre-owned products - amc; zeiss; annual maintenance contract (amc); quarterly; no; 1. routine maintenance, performance checks, re-alignment, repair and replacement of defective components and parts-hv cable assembly, ex mva "x" part-no.: 311311 -orsay , ex mva "y", valve assembly, spare assembly, o-ring iso valve, electro valve, 20 kv high voltage module, leader card holder, pneumatic actuator set, apertures assembly, o-ring for nozzles block, o-ring for aperture drive, steppermotor driver 51xpack2 /trinamic, gis psu, actuation cylinder complete, connector, nozzle head complete, high voltage module, grounding module f/liner tube lens, floater 300v, 0,5a 3/4", ex eht digit. controlled tetrode supply, xb scan piggy board, scan-generator, complete (auriga), e/o board hw4.0(3.5) with fw3.1.0, ex vac.-control board leo 15xx "stan dar, interlock piggy (mod. version), needle valve piggy with mounting parts, vac relay pcb (1400), main psu, fib-electronic pcb complete, deflector amplifier, internal generator, 6 hole aperture, pre-aperture 3h6x0,25/ 0,110mm, anode screw din 7984 m4x6 e, helicoflex-hnv-120-19,7-23,7-2-alu a5, copper gasket, spring+spool f/y axis assy, power supply tpsll0 /pfeiffer vacuum, compact fullrange gauge pkr 251, scintillator assembly, mikro-magnetventil 24 vdc, control pcb water chiller, ion pump, 30l/s noble pump, exhaust, ion pump kit (ion pump+dn35cf) -orsay , ion pump psu(neg) to 910846 1p100/702/02, tip seal kit for nxdsloi pump, illumination assy infrared,compl., spanner wrench, scintillator-changer, pcba 3-channel controller w/rs232, vp holder for 6 hole aperture l00na, extractor - aperture, denka kathode tfe 174c, transmitter extractor voltage, vat civ valve upgrade kit ose au/u/vp, servicepackage hipace 300 plus ose, se-multiplier, complete, pcba 3-channel controller w/rs232, ads 3 jsr m/s repair-kit, membrane f. isol-use# 348201-8902-910, motor assy, step, uhv,sd,1.0a, y-motor assy,step,uhv,sd,1.8a, r motor assembly pllo motor, vac relay pcb (1400), x-spring assembly spool + spring, install.kit for opt. sensor (le-geu-017), on/off-switch complete with pcb, airlock window, pcb for water chiller, asb-detector diode at objective lens, zylinderschraube 2 din912-m4x6, longetterpump 20l, copper sealer dn 40 cf cu pf501404-t, ex fib hv cable assy -orsay , 90u anode aperture, unloader valve for jun air compressor, chiller water pump, van der heijden, water chiller air cooled type, 12v 42ah smf battery for lokva ups, gallium source, gallium source refilled, liner tube assy, fib aperture set 50u,20u,50u,100u,200u,400u, copper gasket for gallium emitter, compressor pi-120-25, 230/50-60hz, dry backing pump system nxdsl0i, set anode screws m4x6 din7984 8x, reservoir pt, cable for penning (new pfeiffer), ex controller f/steerer, ex pcba stage controller, joy stick, controller -2. to keep the equipment in up to-date condition during the period of the contract.-msme exemption - no | startup exemption - no,

Central Government/Public Sector

CTN :38041097 Due date: 21 Dec, 202421 Dec, 2024 NA
Tender For corrigendum : custom bid for services - repair and maintenance of ac modules dc modules and various pcbs of all departmental drilling rigs of ongc tripura asset-work includes but not limited to supply of men, materials, testing equipment / tools etc for fault finding (trouble shooting), repairing, calibration and functional testing of ac modules, dc modules and various pcbs in e1400 series drilling rigs of tripura asset. broad details of the activities to be carried out are as below: a. following jobs are to be carried out in pcbs i. physical checking of healthiness of components & cleaning of the pcbs. ii. checking of voltages at different points in the pcbs after powered up through simulator. iii. replacement of faulty components, limited to 50% cost of the pcb, to make it operational. iv. calibration of pcbs v. on load testing of 12 hrs. continuous loading for satisfactory operational vi. fixing of pcbs in the respective panels b. following jobs are to be carried out in ac module i. visual inspection of module for any loose hardware & cleaning of the module. ii. checking of circuit by using simulator. iii. checking of over frequency tripping. iv. checking of under frequency level. v. under frequency voltage cut back test vi. idle-run ramp and idle trip test vii. throttle regulation check viii. master slave and command circuits check ix. current demodulator check x. automatic voltage regulator check xi. meter circuit check xii. over voltage trip check xiii. reverse power trip check xiv. frequency demodulator check xv. module panel meter check xvi. replacement of faulty components, limited to 50% cost of the ac module, to make it operational. xvii. on load testing of 12 hrs. continuous loading for satisfactory operational xviii. fixing of ac modules in the generator panel c. following jobs are to be carried out in dc-module i. visual inspection of module for any loose hardware & cleaning of the module. ii. dead band and current limit calibrations iii. zero throttle interlock circuit test iv. firing circuit test v. speed feedback circuit test vi. power limit circuit test vii. slave circuit test viii. manual voltage circuit test ix. over current trip calibration test x. meter circuit check xi. replacement of faulty components, limited to 50% cost of the dc module, to make it operational. xii. on load testing of 12 hrs. continuous loading for satisfactory operational xiii. fixing of dc modules in the dcpcr panel d. following jobs are to be carried out in battery charger i. visual inspection and cleaning of components such as transformer, voltmeter, ammeter, pcbs, rectifier, indication lamps and tightening of loose hardware, if any. ii. checking of tripping logics, dc under voltage, dc over voltage, reverse polarity, ac mains fail, over current, over temperature etc. iii. replacement of faulty components, limited to 50% cost of the battery charger, to make it operational.-msme exemption - no | startup exemption - no
 Loading, Please wait...

Connect us via What's Up