Tender For repair of chiller at hvac plant of gicu block-c, igmc shimla. (sh:-providing compressor copper piping, hp switch, lp switch, air sensor and r22 refrigerant gas etc.
Tender For supply of precision air conditioner system d d - total quoted value incl gst for precision air conditioner 8.5 tr for gail bhawan jaipur as per tender and buyback of old pac , total quoted value including gst for unloading lifting shifting of indoor and outdoor to their respective location as as per tender , total quoted value including gst for positoning installation vacuumizing pressure testing and commissioning of precision ac system as per tender , total quoted value including gst for interconnecting copper piping between indoor outdoor hot gas line as per tender , total quoted value including gst for interconnecting copper piping between indoor outdoor liquid line as per tender , total quoted value including gst for interconnecting armoud copper cabling 3 core x 2.5 sqmm between indoor and outdoor unit as per tender , total quoted value including gst for incoming copper cabling from incoming isolator to crac unit 4 core x 16 sqmm as per tender , total quoted value including gst for insulated condensate drain piping with 40nb pvc pipes as per tender , total quoted value including gst for humdifier piping intel connection gi b class 25nb as per tender , total quoted value including gst for humdifier inlet connection isolation valve for each unit connection as per tender , total quoted value including gst for supply and installation of indoor unit ms adjustable stands for each indoor units to dimensions as per tender , total quoted value including gst for supply and installation of outdoor unit ms adjustable stands for each outdoor units to dimensions as per tender , total quoted value incl gst for charging of refrigerant gas r 410a and oil charge required for compressor for the 100 percent rating and equivalent copper pipe length bw indoor and outdoor unit , total quoted value including gst for sequencing controller of units with required cabling and modem router as per tender , total quoted value including gst for cable tray for outdoor piping and cable laying in exposed area as per tender , total quoted value including gst for motorized air damper for each indoor unit to avoid air short cycling in standby mode as per tender , total quoted value including gst for earthing cable 1 c 10 sq mm as per tender , total quoted value including gst for cat 6 cable for communication with d link as per tender , total quoted value including gst for extended piping kit with required fittings as per tender , total quoted value including gst for supply air floor grilles 600 x 600 mm with volume control damper as per tender , total quoted value including gst for dismantling of old pac units including a shifting of old units after dismantling from 3rd floor to scrap yard as per tender , total quoted value including gst for shifting of old units after dismantling from 3rd floor to scrap yard as per tender //bid details 2 / 18
Tender For annual plan ramapuram gp uzhavoor bp project no s0213 26 purchase of lab equipments general electrical work - 1 part i- electrification- and providing ac units( materials used for the work shall be as per list of materials approved by the district level technical committees and attached as separate document), 90.6.10.1:supply and fixing of following sizes of light gauge pvc conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required20 mm, 90.6.10.2:supply and fixing of following sizes of light gauge pvc conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required25 mm, 1.17.20:supplying and drawing following sizes of frls pvc insulated copper conductor, single core cable in the existing surface / recessed steel/ pvc conduit as required.2 x 4 sq. mm, 1.17.21:supplying and drawing following sizes of frls pvc insulated copper conductor, single core cable in the existing surface / recessed steel/ pvc conduit as required.3 x 4 sq. mm, 90.6.5.13:supply and drawing the following sizes of multi-core pvc insulated & frls pvc sheathed 650/1100 v grade copper conductor round flexible cables conforming to is 694 part i 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 4.00 sq mm, 1.24.5:supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet, 1.27.1:supplying and fixing following size/ modules, gi box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 module (75mmx75mm), od52985/2025-2026:supply & fixing 2module metal box with white/ off-white front plate provided with one 20a dp switch modular type in recess including making good the damages, colour washing etc as required (rohs) including giving connections (modular boxes ,switches and accessaries ,make-legrand myrius/mk blenz/havells oro/hager/l&t), 2.10.1:supplying and fixing 5a to 32 a rating, 240/415 volts, 10 ka, ""c"" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing mcbdb complete with connections, testing and commissioning etc. as required.single pole, od63837/2025-2026:supply conveyance installation testing and commissioning of inverter-type wall mounting split ac unit of the following ratings conforming to relevant is suitable for operating on 230v, 50hz, single phase ac supply filled with r-410a or r32refrigerant gas, high energy efficient, rohs compliant, capable of performing functions like cooling, dehumidifying, air circulating, filtering etc. of following capacity including refrigerant copper piping 3mtr with insulation, microprocessorcontrol with cordless remote control etc. - tr 1 phase 3 star rated inverter type split ac unit ( carrier make)( blue star/ daikin / voltas) ( 1 ton 3 star rated ac ), od53026/2025-2026:supply, installation, testing and commissioning of wall mounting split air conditioner unit of the following ratings conforming to relevant is suitable for operating on 230v, 50hz single phase ac supply, filled with r32/410a ecofriendly refrigerant gas, high energy efficient, rohs complaint, capable of performing functions like cooling, dehumidifying, air circulating, filtering etc of following capacity including refrigerant copper piping 3m with insulation, control cable up to 3-5m, 3 m drain pipe, copper condenser, stand, microprocessor control with cordless remote control etc. pcb should have minimum 5 year warranty and 10 year warranty on compressor(warranty card are to be provided). minimum 2 nos free service per year for the entire guarantee period and it should be ensured that the air conditioner is in perfect working condition during this period. 2 tr 3 star inverter a.c unit,
Tender For supply of vrf air conditioning works at state bank of india administrative office lucknow c c - 20 hp outdoor vrv or vrf , 10 hp outdoor vrv or vrf , 4 way 4.0 tr vrf cassette indoor , 4 way 2.0 tr vrf cassette indoor , 4 way 1.35 tr vrf cassette indoor , hi wall 1.35 , y joints , installation of vrv or vrf outdoor , installation of casssette vrv or vrf indoor , installation of hi wall split ac , commisioning of complete vrf system , refrigerant piping 28.6 mm , refrigerant piping 22.2 mm , refrigerant piping 19.1 mm , refrigerant piping 15.9 mm , refrigerant piping 12.7 mm , refrigerant piping 9.5 mm , refrigerant piping 6.4 mm , drain pipe 32 mm , drain pipe 25 mm , control and transmission wiring , ms sloted angle for pipe paying , sitc of 5 star 2 ton cassette a c , copper pipe refrigerant piping for 1.5 or 2 tr , 5 kva automatic stabilizer , interconnecting standard wire cable , outdoor stand for vrv or vrf 20 hp , outdoor stand for vrv or vrf 10 hp
Tender For repairing of damaged enm equipments at tube well no nt 148 at shank no 17 d point palla area ward no 5 baktawakpur ac 01 - lifting of p/set by the help of chain pully, clamps and heavy men menpower after cuting rusted/wornout and opening of nut bolts to dismental the p/set, pipes, valves etc., s/o submersible cable with copper conductor having three core sizes 6 sq. mm working on 1100v. make:-finolex/plaza/unistar or any other make approved by djb., making and supply of ms clamp of 500 mm long x 75 width x 12 mm thick complete with nut and bolts and washers for holding the 100 mm dia pipe including bending and shaping etc. as required., s/o ci/m.s bend 100 mm dia 90deg. double flange. heavy class make: - ganesh/ isi, s/o of 3 mtr. gi pipe 100 mm dia size ,medium class with gi flange welded in both sides 3 mtr long with ms strips complete with threading work on each side of pipe each flange should be 4 holes and cut for cables. make :- jindal / tata., s/o g.i required off size threaded heavy duty nut-bolts of good quality., supply of ms bore cover 4 mm thick suitable for bore size in 2 pieces complete with bolting arrangement angle iron frame and provision of 100 mm dia hole in the center., s/o pressure gauge of 100 mm dia, 0-30 psi complete with socket, bush make:-h-guru/fiebig, making water sample point with the help of socket, niple, cook valve, tee and extended pipe etc. of size 1/2 inch., making and supply of g.i tail piece of 100 mm dia. , one mtr. long size made out of medium class pipe complete with one end threaded and other end fitted with g.i. flange heavy and cut for submersible cable. mak of pipe - jindal/tata., repairing of starter panel board suitable for 20 hp submersible pump set having following works :- 1. replace faulty power contacts.2. replace faulty relays.3. monir wiring work.4. repalce faulty push button and indication lamp.5. painting of panel board., supply of neoprene rubber sheet having 50% neoprene , 3 mm thick make jyoti/worth/djb approved, installation of all e&m equipments, lowering pump set into the bore all piping work fixing of valves and accessories executing minor civil works, making electrical connections with cable as required size by the help of chain pully to lower pump sets testing and commissioning of all e&m equipments at no load and full load conditions as per standard from full satisfaction of engineer-in-charge. the job also includes the transportation charges, providing/fixing of required gap piece, for fixing valves, pressure gauge with the help of welding machine etc. note- the repaired pset will be provide by the departmentlly; if required.
Tender For supply of sitc of floor mounted tower ac at first floor sha at civil airport gorakhpur d d - sitc of 1.5 tr 5 star wall mount split ac , supply and fixing of extra copper refrigerant piping for 1.5 tr split ac , sitc of 2 tr 5 star wall mount split ac , supply and fixing of extra copper refrigerant piping for 2 tr split ac , supply and fixing of 25 mm dia u pvc plumbing drain pipes , sitc of 4 tr floor mounted tower ac , supply and filling of extra refrigerant gas non cfc r32 or r410a , supply and fixing of 32 mm nominal dia rigid upvc drain water piping , making provision of hole in wall rcc cc of 100 mm dia to 150 mm dia , supply of 4c x 2.5 sq mm pvc insulated pvc sheathed stranded copper cable , supply of 4c x 6 sq mm copper conductor power cable , supply of 4c x 25 sq mm copper conductor power cable , laying and fixing of cable , supply installation testing and commissioning 15.9 mm o.d. insulation 13 mm thick suction pipe , supply installation testing and commissioning 9.5 mm o.d. insulation 13 mm thick discharge pipe , supplying and fixing of 12 way double door vtpn mcb db , supplying and fixing 3 pole 32 a rating, 415 v, 10 ka mcb , sitc of 200a, 36ka, 4 pole mccb in the existing vtpn mcb db , providing, fabrication and fixing of approved color painted ms cage or ms mesh or ms jali , providing, fabrication and fixing of painted ms stand for outdoor unit
Tender For renovation of ground floor and mess of maharana pratap hostel of rttc campus in jaipur - group b wiring for light point , wiring for light or power plug with 2x4 sq. mm frls , wiring for light or power plug with 4x4 sq. mm frls , wiring for circuit or submain wiring of size 2 x 1.5 sq mm and 1 x 1.5 sq mm earth wire , wiring for circuit or submain wiring of size 2 x 2.5 sq. mm and 1 x 2.5 sq. mm earth wire , wiring for circuit or submain wiring of size 4 x 2.5 sq. mm and 2 x 2.5 sq. mm earth wire , supplying and drawing of 3 x 1.5 sq. mm sizes of frls , supplying and drawing of 4 x 1.5 sq. mm sizes of frls , supplying and drawing of 5 x 1.5 sq. mm sizes of frls , supplying and drawing of 6 x 1.5 sq. mm sizes of frls , supplying and drawing of 3 x 2.5 sq. mm sizes of frls , supplying and drawing of 6 x 2.5 sq. mm sizes of frls , supplying and drawing of 3 x 4 sq. mm sizes of frls , supplying and drawing of 6 x 4 sq. mm sizes of frls , supplying and fixing of 20 mm size of steel conduit , supplying and fixing of 25 mm size of steel conduit , supplying and fixing two module stepped type electronic fan regulator , supplying and fixing modular blanking plate , supplying and fixing suitable size gi box with 3 pin 5 or 6 amps modular socket , supplying and fixing suitable size gi box with 6 pin 5 or 6 and 15 or 16 amps , providing and fixing of s type or fastner type fan hook , supplying and fixing of 1 or 2 module 75 mm x 75 mm size or modules gi box , supplying and fixing of 3 module 100 mm x 75 mm size or modules gi box , supplying and fixing of 4 module 125 mm x 75 mm size or modules gi box , supplying and fixing of 6 module 200 mm x 75 mm size or modules gi box , supplying and fixing of 8 module 125 mm x 125 mm size or modules gi box , supplying and fixing of 12 module 200 mm x 150 mm size or modules gi box , supplying and fixing 5 or 6 a switch modular , supplying and fixing 15 or 16 a switch modular , supplying and fixing 3 pin 5 or 6 a socket outlet modular , supplying and fixing 6 pin 15 or 16 a socket outlet modular , supplying and fixing modular bell push , supplying and fixing dp sheet steel enclosure , providing and testing ding dong type sound two module call bell , dismentalling of 1200 mm ceiling fan from hostel rooms , itc of above existing 1200mm ceiling fan , dismentalling servicing and complete repairing other than rewinding and itc of 300 mm exhaust fan , dismentalling serviceing and repairing including rewinding and itc of 300 mm exhaust fan , dismentalling servicing and complete repairing other than rewinding and itc of 450 mm exhaust fan , dismentalling serviceing and repairing including rewinding and itc of 450 mm exhaust fan , supplying and fixing 380mm sweep 900 rpm heavy duty tourbo force exhaust fan , sitc ip20 18 20 watt led batten type integrated light fixture , supplying and fixing of vertical type 35 litre capacity 2000 watt water storage electric geyser , supplying and fixing of vertical type 15 litre capacity 2000 watt water storage electric geyser , sitc of ip 40 led surface mounted round smd mid power led 18w downlight , sitc ip20 10 watt led batten type integrated light fixture , sitc of 400 mm sweep oscillating type wall mounted cabin fan , installation of upto 2 tr capacity split ac units , pdg and fixing 1 by 4 inch dia copper refrigerant piping , pdg and fixing 5 by 8 inch dia copper refrigerant piping , provision of top up or additional charging of r-22 or 32 gas , s f suitable size ms stand for placement of split type ac outdoor unit , providing and fixing 20 mm dia heavy duty pvc pipe , supplying and fixing 25 amp moduler type starter , supplying and fixing of 3 x 2.5 sq mm pvc insulated and frls , repairing and painting of existing 3 mtr height galvanised mild steel pole , repairing and painting of existing 7 mtr height galvanised mild steel pole , supply installation testing commissioning of led post top type 27 watt with ip 65 , sitc of 18 watt energy efficient led type 12 inch size pol
Tender For corrigendum : supply, installation, testing and commissioning of independent air conditioner units and associated ventilation ducting, structural supports, copper tubing and carbon steel piping, communication and power cabling, anti corrosive painting,
Tender For supplying and installation of insulated refrigerant copper tubing of 5/8" and 3/8" with polythe ne foam insulation 3 core 80 stand copper wiring between indoor and outdoor unit leak testing oil and gas c harging for additional piping length of tube(in addition to suplied quantity along with ac utilized if required) [ warranty period: 30 months after the date of delivery ]