Tender For supply of advanced tissue cassette laser printing machine with 01 year warranty period,02nd year warranty cost of equipment,03rd year warranty cost of equipment,04th year warranty cost of equipment,05th year warranty cost of equipment
Tender For supply of it equipment e e - computer , projecter short throw , motorised projecter screen , laser pointer red green , audio dsp twelve channel , amplifier two hundred watt , wall mount speaker , collar mic , usb three point zero cable thirty meter , usb three point zero cable fiveteen meter , hdmi cable thirty meter , hdmi cable fifteen meter , cable drum cat six , hdmi switcher four in one out , cordless mic , manageable sw twenty four port
Tender For corrigendum : for year 2025-2026 providing and supplying equipment and general material for pangarkhed grampanchayat tq. mehkar dist. buldhana - sound system, projec set, photo galary / board, round larges table, fiber chair, stainless steel chair, wheel chair, days, office kapat, invertor with all accesseries, invertor battery, seiling fan, table fan, fan pedstal, white board, photo copier machine, computer set, r.o. filter set, drinking water tank 500 lter, drinking water tank 1000 lter, gas bhatta, shavadhini, tiridi steel, solar semi intergrated all in one (solar semi intergrated all in one 6 mtr pole, panel 60 wt, bracket pole, bracket panel, installation, gst, transportation etc), led street lights 36 wt (led street light 36 wt lence model with water resistant, g.i. pipe, pole clam, installation, transportation with two years piss to warranty), office table, r.c. can, laser printer, ups, anti various, wireless mouse, keyboard, pen drive, rim paper, cctv setup (dvr, cable, etc led tv), cement bench, e-learning software, sanitary pad, hand wash, table kach, dustbeen 120, sanitary disposal machine, sanitary wedding machine, colour 10 ltr, colour 30 ltr, national flag, electric motor pump 1.5 hp, rcc septic with cover, 5 hp, 3 hp motor pump, 3 hp motor pump, 7.5 hp, 3 hp, dustbeen 15 ltr, colour printer, internet router, dell leptop (dell laptop i5, 13th generation, windows 11, adaptor etc 1 year warranty), road safety mirror with pole, digital school learning panel, star banner, digital watch, digital micro sound system, kukar 15 ltr, steel water tank, kadai, patile mothe, dhanya kothi, gas bhatta, pendrive 64 gb, air condition 2 ton, exit fan, ssd 1 tb, tent cooler, cooler 120 ltr, office kapat 4 x 5 feet, office kapat 6 x 8 feet, rack, shamiyana, , , ( ), / ( ),
Tender For corrigendum : procurement of it equipment under ulmmc - procurement of it equipment under ulmmc, multi-purpose colour laser printer with cartridge (for printing 10,000 pages), photocopier - lan / wifi, a3 and a4 page supported with cartridge (for printing 50,000 pages), workstation, desktop p.c. i7 processor or more, aio p.c. i5 processor or more, laptop (two in one touch laptop), multi-purpose (all in one) laser printer with cartridge (for printing 10,000 pages)
Tender For corrigendum : purchase of biomechanical lab - force platedimensions (w x d x h) in mm : 600 x 400 x up to 50 number of axes for force measurement: all 3 axes. x,y,z plate should be portable in naturesensor type: piezoelectricsampling frequency-(hz) =1000 hz or more force measured on each axis-fx,fy: 2,000 newton or more, fz: 10,000 newton or more hysteresis- (%fso): 0.5 linearity (%fso) 0.5 crosstalk (%) : 2water resistance rating: ip 50 or better.should be inclusive of installation.should be supplied with carrying case for 2 plates and noise free ups for on-ground assessment. the carrying case should be strong and sturdy.should be able to accommodate portable force plate 9286 ba, daq box 5695 and connecting cablesshould be able to protect the equipment from rain, impact and dust, should have rollers to move easilyshould be able to accommodate an ups also., isokinetic dynamometershould be able to access/test various joints in isolation should be able to meet requirements to test sports personsshould be able to test in different resistance modes such as isokinetic (concentric-concentric, concentric-eccentric ,eccentric, concentric ,and eccentric-eccentric), isotonic, isometric, and passive protocols should include options for angles, hold-times, rest period, repetitions, and sets. the system should be able to test all the major body segments and joints such as shoulder, forearm, elbow, wrist, hip, knee, and ankle.should have adjustable range of motion stops in full 360 degrees.should have 360-degree rotation for the force arm (connecting dynamometer to the pedal) to have wide range of motionshould be able to accommodate different athletes with varying height and weight with provision for seatbelt harness for better stabilitythe dynamometer or chair should be movable to accommodate different athletes for quick set-up and better usability with locking clamps for securing the system in place for testingshould be able to do gravity correction when the limbs are positioned with the lever arm on the dynamometerthe software should be provided to analyze the raw data and export the raw and processed data in different file formats such as excel, text, etc. the software should provide detailed report for various testing protocols such as individual test for joints, data/graph overlay for comparing pre and post testing, repeatability, progress, multi-session.should be provided with latest compatible workstation/laptop of reputed brand like hp, dell (latest generation) processor, minimum16gb ram, windows os 11, and laser printerconcentric speed: 500 deg/sec or more eccentric speed: 500 deg/sec or more concentric torque: 500 ft-lb (678nm) or more eccentric torque: 500 ft-lb (678 nm) or more isometric torque: 500 ft-lb (678 nm) or more isotonic torque: 500 ft-lb (678 nm) or more isotonic torque as low as .5 ft-lbfeedback formats: roadway, interactive line, interactive path, reaction training, proprioception training, breakout, and pong.torques. time, torques. angle, torque bars, work bars, power bars. it should be possible to use mechanical stops even with custom patterns (important for safety in research)the same attachment should be usable for left and right side of subject for consistencies in data.should be certified and approved by ce/eu medical devices directives or usfda, nord boardit should be portable and should have 2 load cell sensors per unit with easy to attach hooks pivoting 360 degrees joint improving sensor accuracy it should have knee position indicator for replication of test position in each time. should have sample rate per sensor: upto 400hz, capacity per sensor: 100 kg/980-1000n safe over load per sensor: 150kg/1500n, max over load per sensor: 200kg/ 2000n, resolution: 1n and sensitivity: 22.0+/-mv/v. should have rechargeable battery & battery life should be100 active hours approx. should have working temperature range 5-40 c. (all weather proof) latest upgradable software should have both wired & wireless conne
Tender For inverted fluorescent cell imager with digital camera along with relent equipment - supply of equipment, inverted fluorescent cell imager with digital camera (with one split ac 1.5 ton and latest desktop computer i5 pc 12th gen. (1tb) with laser printer. (according to above specification)