Tender For corrigendum : supply of fixed clean agent gas based cylinderless fire suppression system (q2) , portable fire extinguishers (v2) as per is 15683:2018 (q2)
Tender For supply of title 1 to 12 - providing, installing, testing and commissioning of silent type diesel generating setcomplying with cpcb iv+ alongwith having prime power rating of 250 kva, 415 volts at 1500rpm, 0.8 lagging power factor at 415v suitable for 50 hz, 3 phase system & for 0.85 loadfactor including credit for dismantle material of old unserviceble dg set and consisting of thefollowings , fabricating, installing, testing & commissioning of automatic mains failure control suitable for250 kva silent type dg set with credit for dismantle material of amf complete with relays,timers, set of cts for metering & protection and energy analyser to indicate currents, phase andline voltages, frequency, power factor, kwh, kvarh & provision for overload, short circuit,earth fault, under frequency, control cabling from amf panel to diesel engine and elsewhere ifrequired, all complete and interlocking including the followin , supplying and fixing exhaust gas piping of suitable dia. welded black ms, b class pipeconforming to is:3589 cut to required lengths and installed with necessary bends, supports andclamps, anti-vibration mountings, insulation of exhaust system with mineral wool/rockwool, 50mm thick wiremesh & aluminum cladding etc., as required as per specification , supply and laying of of 3.5 x 185 sq mm sizes of xlpe insulated pvc sheathed aluminiumconductor armoured power cable of 1.1 kv grade confirming to is:7098 (part 1) includingmaking connection with suitable size of aluminum lugs, laying on wall/surface, testing etc. asrequired. , supply, installation, commissioning & testing of complete set of maintenance free chemicalearthing with copper bonded electrode suitable dia & length 50 x 6 mm pure copper internalstrip with suitable terminal, ground enhancement material / back fill compound / groundingcompound of permanent & maintenance free nature. (50 kg. for each earth pit) , providing and fixing 25 mm x 5 mm copper strip on surface or in recess for connections etc. asrequired. , sitc of clean agent based tube fire suppression system 2 kg 10 mtr. heat sensing ul listedtube with ul listed fk5-1-12 clean agent gas , supply & laying of 10 core x 2.5 sq mm copper conductor control cable of insulation:-xlpe(cross linked polyethylene / pvc), inner sheath:- pvc (polyvinyl chloride) st-2 / frls,armouring:- galvanized steel flat strip or round wire, outer sheath:-pvc (polyvinyl chloride)st-2 / frls i/c making connection, testing, laying on wall/surface & commisioning etc completeas required , supply & laying of 3 core x 2.5 sq mm copper conductor control cable of insulation:-xlpe(cross linked polyethylene / pvc), inner sheath:- pvc (polyvinyl chloride) st-2 / frls,armouring:- galvanized steel flat strip or round wire, outer sheath:-pvc (polyvinyl chloride)st-2 / frls i/c making connection, testing, laying on wall/surface & commisioning etc completeas required , supplying and making end termination of size 3 x 185 sq. mm (57mm) with brass compressiongland and aluminium lugs for following size of pvc insulated and pvc sheathed / xlpealuminium conductor cable of 1.1 kv grade as required. , 1 supply installation testing and commissioning of avm pads ecs 25x400 suitable for dg set. 1 , supply of high speed diesel for operation of dg set i/c cartage filling etc. complete as require
Tender For supply of supply of (e&m) item-, supplying of one number 3.5c x 300 sq.mm pvc insulated and pvc sheathed/xipe al. armoured conductor power cable of 1.1 kv grade of following ways complete etc as reqd., supplyof 2 kg hfc 227 ca/fk-5-1-12 with 10 mtr minimum heat sensing tube fire suppression system. clean agent hfc 227 ca/fk-5-1-12 dlp (direct low pressure) with zero ozone depletion potential. container along with valve assembly: clean agent hfc 227 ca/fk-5-1-12 direct complete as reqd operating pressure is 15 bar at 20 degree. sensor tube automatic fire suppression system, made by special modified polyamide double layered color blue/black/red, high grade hr quality, stabilized, inner diameter 4mm.outer diameter 6mm, sensor tubing hr blue/black/red in mtr. senso tube uv resistance with pressurization of tube using nitrogen gas. the hst conductive, non-corrosive and flexible. operating pressure: 15 bar end of line plug-maximum working pressure 20 bar. t connections., pressure switch. pressure valve - direct low pressure type with inbuilt pressure gauge, integrated ball valve for open/ close within the valve body. reed switch to monitor the valve position using the reed switch relay to indicate valve open/close position. power back up for monitoring panel- 12v, 7.2 ah smf batteries (2 nos) end line adopter. 2x1.5 sq. mm pvc insulated pvc seethed copper conductor single core cable wire in meter. required compelete system certification that is equivalent to lpcb standard equivalent to lps 1666: issue 1.0 with indian nabl. lab report., supply of low pressure is 16018 45 itr trolley mounted water mist & caf fire extinguisher with following specifications: water mist & caf fire extinguisher having fire rating 204, 2338 and dielectric test on is: 16018: 2012 (c1.6.8) 36kv at 1 meter distance, with standard afff 3% compound, confirming to is 4989. extinguishing gun stainless steel 1-2 kg approx weight with nabl test report. dual nozzle jet mode to spray mode by twisting of nozzle. suitable for all classes of fire a. b and e. pressure vessel with 45 liter nilling capacity. compressed air cylinder 6 liter 300 bar cylinder which can be inounted on universal air cylinder holder capable of holding these cylinders, length of hose 5 meter, the cylinder should be of red color with powder coating as per is standards the paint should confirm to is: 5:2007 shade 538., cylinders. lancing distance of gun 3-15 meter, flow rate 42 to 50 liter per second. system test: tested from nabl lab/erda, 1) content-water, foam, 2) gun mode jet and spray., supply & foxing of 100 watt led highway light suitable for 120 to 300v of cct(k) $700 lumen efficacy >130, cri minimum 70, mech, impact protection code above ik.08 having pic housing luminaire for enhanced uniform illumination and with ip66/65 protection i/c connection ete complete as reqd.,
Tender For annual maintenance contract of gas suppression and fa system (as per inventory enclosed) installed at directorate of census operations & special bureau c-4a, at gpoa rajaji bhawan, chennai-600 090
Tender For supply, installation, testing and commissioning of gas suppression system in electrical panel in 11 kv sub station and ups room basement nci aiims jhajjar haryana
Tender For installation of new stand alone mssr at maharana pratap airport, udaipur. sh: sitc of gas based fire suppression system & fire detection and alarm system.