Get complete information related to latest Milling Service Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Milling Service Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Milling Service Tenders.
Tender For providing of custom bid for services - cleaning of locomotive cab and lookout glass (no of locomotives available at pnbe juncion - 80 no dnr - 35 no, tia - 35 no total no locomoties in 02 years (150 x 730) 109500 no,custom bid for services - sand filling of sand boxes of electric / diesel locomotives including minor repair of sanding arrangement at pnbe, dnr and tia junction / station / yard total no of loco in 02 year 730 x 100 73000 no,custom bid for services - supply of clean silica sand free from clay, loam, mica and other foreign material as per rdso specification no-aar m916-51,rev-1994 or12kg sand packed and stitched in a water proof laminated plastic/gunny bag qty 876000kg,custom bid for services - cost for cleaning and sweeping of crew lobby danapur and trip shed danapur building, bathroom toilet, urinal, surrounding area including garbage disposal and gardening qty 13195108 sq feet,custom bid for services - supply of cleaning material as per scope of work for 02 years
Tender For corrigendum : "name of work : (a) provn of 02 x borewells with 25 hp motor and water pipe line connecting to existing over head tank of 50,000 gallon near double story qtr at 506 army base wksp, (b) spl repair/repair/replacement of shutters/doors at all repair bays of 506 abw, (c) repalcement /provn of electric motors and lt drive systems in eot cranes installed at arg bay and brake system of eot cranes installed at bofors section of 506 abw, (d) spl repair to lightening protection sys for mag no 01,03,04,05,06,07,08,10,13,15,17,26,30,31,32,33,35,36,37 electric room near mag no 37 ata old lab & ata proof yard and proof chember at asd of cod, (e)provn of 25 x desert window air cooler with stand ( iron) for jcos/ors in otm bldg of adm area of 506 abw under ge(e) jabalpur (f) provn of borewell for dilip complex alongwith oh filling pt at cmm jabalpur."
Tender For supply labour and tractor trolly/chota hathi/tempo for differant place of water logging removing work at ambawali area in navrangpura , and potholes filling work and diffrent work of water,drianag/strowm water and building division work in mon seassion in navrangpura ward at west zone.(arc)
Tender For supply labour and tractor trolly/chota hathi/tempo for differant place of water logging removing work, potholes filling work and diffrent work of water,drianag/strowm water and building division work in mon seassion in navrangpura ward at west zone.(arc)
Tender For tender for material supplying and repairing all type of sizes pipe with fitting with excavation-filling work under water supply department year 2025-26
Tender For fabrication and supply of bathroom and toilet block - fabrication and supply of bc and tb of size 2440 mm x 1860 mm x 2440 mm height in front side and 2100 mm on rear side made up of puf panel , ordinary portland cement 43 grade confirming to is 8112 in 50 kgs hdpe bags make ambuja oblique acc oblique ultratech , fine aggregate sand of best quality confirming to is 383 1970 , crushed stone aggregate 20mm grade confirming to is 383 1970 , crushed stone aggregate 40mm grade confirming to is 383 1970 , hard core stone aggregate not exceeding 63 mm , well burnt common building bricks of sub class b of size 23 x 11 point 5 x 7 point 5 cm conforming to is 1077 , brick bats , non skid ceramic coloured tiles of 400x400x 7 to 8 mm thick first quality heavy duty abrasion resistant confirming to is 15622 make johnson oblique katarina oblique orient , bitumen joint filling compound grade b confirming to is 1834 to 1984 make stp ltd oblique htp ltd oblique tiki tar industries , primer for cement plaster surfaces make dulux oblique berger oblique nerolac , wpc comma as per is 2645 to 1975 makedr fixit oblique sikka oblique hardrock , white cement make acc oblique birla white oblique ambuja , cement based paint make berger oblique shalimar oblique asian paints , iron welding rod pkt of 100 pcs , oil bound distemper off white make berger oblique shalimar oblique asian paints , sand paper , turpentine oil , painting brush 4 inch isi marked , painting brush 3 inch isi marked , red oxide primer confirming to is 104 to 1979 make berger oblique nerolac oblique asian paints , paint synthetic enamel black colour confirming to is 2074 1979 make make berger oblique nerolac oblique asian paints , soap dish chromium plated make ess ess oblique johnson suissegem oblique pryag , angle iron staging of size 1 point 50 mtr x 1 point 50mtr and clear height 2 point 5mtr with vertical ms angle columns of size 65x65x6mm with ms sheet 2mm thick fitted at top of the staging work , septic tank cover of size 2 point 51 x 1 point 26 m with angle iron 50 x 50 x 5 mm with all around and cross bracing and 2 point 0 mm thick ms sheet including 02 nos of 600 x 600 mm size , soakage pit cover of size 1 point 60 x1 point 60 mtr with angle iron 50 x 50 x 5 mm with all around and cross bracing and 2 point 0 mm thick ms sheet including 600 x 600 mm opening with 02 , manhole cover of size 900 x 900 mm with angle iron 40 x40x 5mm with all around and cross bracing and 2 point 0mm thick ms sheet with 02 nos of ms handle , precast rcc baffle wall of size 1200 x 1000 x 75 mm in rcc m 25 grade concrete with reinforcement 10 mm dia tmt bar 150 mm c oblique c both ways complete for fixing in flooring of septic tank , precast rcc baffle wall of size 1150 x 1000 x 75 mm with rcc lintel of size 75 x 100 mm in rcc m 25 grade concrete with reinforcement 10 mm dia tmt bar 150 mm c oblique c , pvc rotational moulded high density polyethylene hdpe triple layer water storage tank cylindrical vertical tank 1000 ltrs capacity , gi socket 15mm isi marked confirming to is 1239 make ravindra oblique jindal oblique tata , gi elbow 15mm isi marked confirming to is 1239 make ravindra oblique jindal oblique tata , gi tee 15mm comma isi marked confirming to is 1239 make tata oblique jindal oblique ravindra , gi union 15mm comma isi marked confirming to is 1239 make tata oblique jindal oblique ravindra , 15mm bore dia brass bib cock weight not less than 330 gm make ess ess oblique johnson suisse gem oblique prayag , gi pipe 15mm dia comma isi marked make tata oblique jindal oblique ravindra , gi nipple 15mm 3 inch long make tata oblique jindal oblique ravindra , gi plug 15mm make tata oblique jindal oblique ravindra , 15mm dia pvc connection pipe 45 cm long make supreme oblique johnson suisse oblique famingo oblique isi , gi socket reducer 20 to 15mm comma confirming to is 1239 1989 make unique oblique tata oblique jindal , gi pipe 20mm dia med grade confirming to is 1239 make jindal oblique tata oblique
Tender For work contract of interior mechanical and electrical "furnishings & fittings including interior & exterior plumbing fittings and additional water filling arrangement / activities with coach lowering" in lwscn eog lhb type non ac coaches with fiat bogies as per scope of work.
Tender For custom bid for services - rpnc252027 support service for swing extruder vfd installation-shifting, foundation and installation of power transformer- 1. the power transformer is to be installed by construction of new transformer foundation, dismantling/modification of surface, providing chain link fencing on all other 4 sides, cleaning and refurbishment of bay area is in the scope of contractor only. all necessary manpower, tools & tackles, shifting machinery like hydra/crane etc shall be in the scope of contractor only. 2. shifting of power transformer of 7.2 mva onan from store to site, loading-unloading, erection, site storage are in scope of contractor. 3. the basic data sheet and ga drawing of the proposed transformer is attached in scope only. 4. the bidder if required must construct bay width, height and fire walls as per relevant is/iec/oisd standards and site conditions such that adequate clearances for maintenance shall be maintained. bidder to submit the plot plan of equipment layout of transformer layout along with the bid. the bidder shall carryout the site visit for assessment of the available installation space. the total length of the transformer bay should be such that the radiator can be accommodated on either side of transformer tank in the specified bay width. 5. all necessary earth pit provisions, & fire barriers/wall modifications, provision of new hvws water sprinklerbased firefighting system having suitable capacity for protection against the fire & explosion as per the design of supplied transformer and applicable standards & direction of eic. provision of all necessary fire protection system for transformers shall be in the scope of lstk contractor. 6. construction of oil drain facility of transformer as per is standard and hookup with existing burn oil pit. 7. the erection to be certified by contractor as per its recommended procedures which is to be submitted prior to erection. qap for erection and site commissioning shall also to be endorsed by contractor. 8. all kind of lifting, rigging work for loading-unloading, erection work including supply of hydra/ cranes, lifting rigging materials, manpower, tools and tackles as required are in scope of contractor. 9. all kind of skilled, semi-skilled, unskilled manpower as per itc of transformer requirement will be in the scope of contractor. 10. erection includes entire vacuum by proper capacity of vacuum pump, for not less than 48 hours, or more if required as per the instruction of engineer in charge. 11. first filling up of the transformer oil at site, its filtration, site testing oil sample, any refiltration required during final commissioning shall be in the scope of contractor including all tools, tackles and including oil filtration machines. oil may be supplied in drums, which should be properly sealed during transportation and storage. seal shall be verified and opened in front of iocl representative before filling in transformer. contractor should have enough storage capacity for handling oil. filling the oil from drums to the transformer through suitable capacity of high-quality filter machine and filtration of the same to get desired bdv &ppm as specified by engineer in charge and transformer manual. 12. contractor must replace all the gaskets by new ones if required by engineer in charge. 13. the contractor shall arrange nitrogen cylinder required at site for above work. 14. contractor must repaint the transformer tank with two coats of anti-rusting good finish ltbs grey shade 631 of is:5 by spray painting if required and as per the direction of engineer in charge..
Tender For providing of custom bid for services - hiring of 13-3/8 inch whip stock with window millingservices for a period of three years on call out basis