Tender For corrigendum : supply of spare of lt vfd at hurl sindri on oem basis - dual temperature transmitter, filter capacitor for sine wave filter, current transformer ratio - 100/1a, vfd control device, vfd power device, hrc fuse link bs type, fuse holders & isolating link, hrc fuse bs type, fuse-link rating-80a, ac 690 v., fuse base nh din type, "6"" output filter ral 7035 size 6 incfan failure and temp detection unitiop (intelligent operator panel)power contactor rating-45a, 230v ac", "sine wave filter reactor rating -22kwpanel fanmulti-function meter (mfm)32-50 a, thermal overload relay""", circuit breaker with electronic trip, panel door mounted rotary op. handles, d series dc drm relay, d series drm relay socket, 4 contacts, d series ac drm relay, 5a, d series ac drm relay, 10a, d series drm relay socket, 2 contacts, digital indicator (rpm meter), transformer, 415vac/240vac, 500va, auto transformer, 22kva 3 pole, current transducer specs-4-20ma, motor restart timer, green push button & contact block, red push button & contact block, selector switch, 2-way, selector switch, 3-way, blue push button & contact block., yellow push button & contact block, black push button & contact block, fuse terminal, thermostate, high current connectors, 40mm insulator, 30mm insulator, indicating lamp, red, indicating lamp, yellow, indicating lamp, blue, indicating lamp, green, indicating lamp, amber
Tender For corrigendum : supply of conductivity analyzer element contacting type plus transmitter, range 0-100 microsiemens, element make- model-rosemount 400-11, transmitter make-model- rosemount 1066-c-ht-60. , differential pressure transmitter, range 0-0.6 kg per cm2, make-rosemount model-2051cd2a03a1bs5m5q4 plus 305rc32b11b4l4. , orifice plate plus diaphragm type pressure transmitter, range 0-80 m3 per hr, make-rosemount model- 2051cd2a03a1bs5m5q4 plus 305rc32b11b4l4. , diaphragm type pressure transmitter, range 0-1.3 kg per cm2 abs, make-rosemount, model- 2088a1s33a1m5b4d4q4s5 plus 0306rt22ba11. , diaphragm type pressure transmitter, range 0-1.6 kg per cm2 abs, make-rosemount, model- 2088a1s33a1m5b4d4q4s5 per 0306rt22ba11. , diaphragm type pressure transmitter, range 0-5 kg per cm2 abs, make- rosemount, model-2088a1s33a1m5b4d4q4s5 per 0306rt22ba11. , diaphragm type pressure transmitter, range 0-10 kg per cm2 abs, make-rosemount, model- 2088a1s33a1m5b4d4q4s5 plus 0306rt22ba11. , diaphragm type pressure transmitter, range 0-11 kg per cm2 abs, make-rosemount, model- 2088a1s33a1m5b4d4q4s5 plus 0306rt22ba11. , diaphragm type pressure transmitter, range 0-6 kg per cm2 abs, make-rosemount, model-2088a1s33a1m5b4d4q4s5 plus 0306rt22ba11. , diaphragm type pressure transmitter, range 0-12 kg per cm2 abs, make-rosemount, model- 2088a1s33a1m5b4d4q4s5 plus 0306rt22ba11. , vibrating level switch, make-rosemount, model- 2120d1dv1naaa0000. , radar type level transmitter, range 0-760mm, make-rosemount, model- 5408a1sha1na7r3aasaa3q4. , radar type level transmitter, range 0-14m, make-rosemount model- 5408a1sha1na7r3aasaa3q4. , temperature element rtd, range 0-100 degc, rtd make-model-rosemount 214crwma1d3e0077slat1c3uae030x8q4 plus 114ce0060tac2sc017b. , diaphragm type pressure transmitter, range 0-4 kg per cm2, make-rosemount, model-2088a2s33a1m5b4d4q4s5 plus 0306rt22ba11. , ph analyzer and tranmitter, range 0-14, element make-model- rosemount 3900-02-10, transmitter make-model- rosemount 1066-p-ht-60. , chlorine analyzer and transmitter, make rosemount, model fcl-02-221 plus 1056- 02-24-32-an.
Tender For corrigendum : supply of spare parts of elgi compressor - spare parts for elgi air compressor type el07335, air lube plus long life oil 20 ltrs drum, kit mof cfr 350-10s-149-g2n, 220444059, obs mof hfr 20-10-25g2n, 220446019, air filter kit - 499, 220419499, elbow rubber 6 inch, actuator hose 22047645b, neuron ii controller 00897701n, pressure transmitter, 008979010, spare parts for elgi air compressor type el07335, separator element 1600 cfm part no. 8677701
Tender For corrigendum : providing of repair and overhauling service - multifunction machines mfm; repair of rt-1601 receiver/transmitter; yes; service provider premises