Web Analytics Made Easy - StatCounter

Modems Tenders

Get complete information related to latest Modems Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Modems Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Modems Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

State Government

CTN :38158820 Due date: 26 Nov, 202426 Nov, 2024 43.77 Lacs
Tender For scope of work covers supply, installation, commissioning of 3d level scanner type bunker raw coal level measurement system for unit 2 comprising of acoustic frequency based 3d level scanners, pc, electronic modules, splitters, modems, junction boxes, mounting kit, enclosures, interconnecting cables, software and all other accessories required to make the system complete and fully functional, shall be provided for continuous level measurement and monitoring of level of each coal bunker and also to ensure satisfactory performance of the system commissioned at rtps site which shall be on the basis of single point responsibility, completely covering the activities and services in respect of all the equipment & works specified and covered under the specifications. detailed technical specification and scope of work is available at section ii ,iii & iv in tender document

CTN :38064137 Due date: 22 Nov, 202422 Nov, 2024 NA
Tender For supply of 0.5 s high precision 3 ph. 4 wire ,-/5 amp ht tvm & 0.2 s high precision 3 ph. 3 wire ,-/1 amp ht tvm, with dlms with modems and test terminal blocks as per specifications, terms and condition of dgvcl tender

CTN :37622400 Due date: 22 Nov, 202422 Nov, 2024 50.60 Crore
Tender For corrigendum : construction of 220 160 mva and 132 kv 50 mva gss at hindore rajiasar distt sriganganagar in rajasthan including survey supply of all smaterials erection including civil works testing and commissioning turnkey project - main material/ items, circuit breakers, 220 kv circuit breakers, 220kv circuit breakers (3 ph.) along with support structure, 2500 a, 50 ka, 132 kv circuit breakers, 132 kv circuit breakers (3 ph.) along with support structure, 1250 a, 40 ka, 33 kv circuit breakers, 33 kv circuit breakers (3 ph.) along with support structure, 1250 a, 25 ka, instrument transformers, capacitor voltage transformer, single-phase, 220 kv, 4400 pf cvt, single phase 132 kv , 4400 pf cvt, 33 kv potential transformer, 33/ 3 kv /110-110 3, current transformer (1-phase), 220 kv ct, 1000/1 a, 5c, 132 kv ct, 1000/1 a, 3c, 500/1 a, 3c, 33 kv ct, 1000/1 a, 4c, 500/1a, 2c, c&r panels & sas system (complete in all respect, refer section-v a, b, part-iii, volume-ii), new substation, control panel for 220 kv transformer (220 kv side) type: sas-thcb, relay panel for 220 kv transformer (for both hv & mv) type: sas-thrb, control panel for 220 kv feeder type: sas-fcb, relay panel for 220 kv feeder type: sas-frb, control panel for 220 kv bus coupler type: sas-bccb, relay panel for 220 kv bus coupler type: sas-bcrb, 220 kv busbar protection relay panel type: sas-bbrb, control panel for 220 kv transformer (132 kv side) type: sas-tlcb, relay panel for 220 kv transformer (132 kv side) type: sas-tlrb, control and relay panel for 1x 50/31.5/25 mva, 132/33 kv power transformer type sas-tcra, control panel for 132 kv feeder type sas-fca, relay panel for 132 kv feeder type sas-fra, control and relay panel for 132 kv bus-coupler type sas-bcra, control and protection panel for 33 kv feeder (i/c, o/g)/bus-coupler/ capacitor bank [for twin feeder/bay] type-fcrd, station hmi [industrial grade computer with 21"tft monitor as per specification requirements], station hmi (hot standby)[industrial grade computer with 21"tft monitor as per specification requirements], hmi view node[industrial grad computer with 21"tft monitor as per specification requirements], a3 size b&w laser printer, substation automation system network panel type sas-nw, modems (both sending and receiving end) for communication to rcc & sub sldc for plcc], data concentrator unit (dcu) at substation for ras mounted in suitable enclosure & fully wired, software: application as well as system software as per specification requirements for various hardware elements for meeting of functional requirement of the specification., substation auxiliary monitoring panel type sas-samp, other items:, fiber optic cables, connectors, ethernet cables, jack panels connectors, patch cords etc. for completing the substation lan as per specification requirements., transducers, sensors etc. (if not considered in the respective equipment/ items) for accumulating monitoring data as per the specification requirements for switchyards., surge arresters, 220 kv la, 132 kv la, 33 kv la, substation lt transformer, 33/ 0.433 kv, 250 kva lt transformer complete with all accessories, fittings, terminal connectors etc as specified filled with transformer oil, batteries & battery charger, batteries (sizing shall be as per requirement of technical specification), 220 v [min. 600 ah], 48 v [min. 600 ah], battery charger system, 220 v float and boost, 50 v float and boost, lighting system, outdoor lighting & other works, lighting fixture type fl-1, lighting fixture type fl-2, outdoor receptacle, type-rp, type-ro, substation premises lighting, lighting poles, type-l1, type-d1, street lighting type-sl-l1 for mounting on poles, street lighting type-sl-d1 for mounting on poles, sub-lighting boxes/panels type -slp at lighting mast and other loaction as designated complete with all controgears and accessories, items etc., lighting panel type acp-2 as per technical specification, lighting panel typ

CTN :37622467 Due date: 22 Nov, 202422 Nov, 2024 46.45 Crore
Tender For corrigendum : construction of 220/132 kv, 1x160 mva and 132/33 kv, 1x40/50 mva gss at 220 kv gss kolayat (distt-bikaner) in rajasthan including survey, supply of all equipments/materials, erection (including civil works), testing and commissioning (turnkey ) - main material/ items, circuit breakers, 220 kv circuit breakers, 220kv circuit breakers (3 ph.) along with support structure, 2500 a, 50 ka, 132 kv circuit breakers, 132 kv circuit breakers (3 ph.) along with support structure, 1250 a, 40 ka, 33 kv circuit breakers, 33 kv circuit breakers (3 ph.) along with support structure, 1600 a, 31.5 ka, instrument transformers, capacitor voltage transformer, single-phase, 220 kv, 4400 pf cvt, single phase 132 kv , 4400 pf cvt, 33 kv potential transformer, 33/ 3 kv /110-110 3, current transformer (1-phase), 220 kv ct, 1000/1 a, 5c, 132 kv ct, 1000/1 a, 3c, 500/1 a, 3c, 33 kv ct, 1000/1 a, 4c, 500/1a, 2c, c&r panels & sas system (complete in all respect, refer section-v a, b, part-iii, volume-ii), new substation, control panel for 220 kv transformer (220 kv side) type: sas-thcb, relay panel for 220 kv transformer (for both hv & mv) type: sas-thrb, control panel for 220 kv feeder type: sas-fcb, relay panel for 220 kv feeder type: sas-frb, control panel for 220 kv bus coupler type: sas-bccb, relay panel for 220 kv bus coupler type: sas-bcrb, 220 kv busbar protection relay panel type: sas-bbrb, control panel for 220 kv transformer (132 kv side) type: sas-tlcb, relay panel for 220 kv transformer (132 kv side) type: sas-tlrb, control and relay panel for 1x 40/50 mva, 132/33 kv power transformer type sas-tcra, control panel for 132 kv feeder type sas-fca, relay panel for 132 kv feeder type sas-fra, control and relay panel for 132 kv bus-coupler type sas-bcra, control and protection panel for 33 kv feeder (i/c, o/g)/bus-coupler/ capacitor bank [for twin feeder/bay] type-fcrd, station hmi [industrial grade computer with 21"tft monitor as per specification requirements], station hmi (hot standby)[industrial grade computer with 21"tft monitor as per specification requirements], hmi view node[industrial grad computer with 21"tft monitor as per specification requirements], a3 size b&w laser printer, substation automation system network panel type sas-nw, modems (both sending and receiving end) for communication to rcc & sub sldc for plcc], data concentrator unit (dcu) at substation for ras mounted in suitable enclosure & fully wired, software: application as well as system software as per specification requirements for various hardware elements for meeting of functional requirement of the specification., substation auxiliary monitoring panel type sas-samp, other items:, fiber optic cables, connectors, ethernet cables, jack panels connectors, patch cords etc. for completing the substation lan as per specification requirements., transducers, sensors etc. (if not considered in the respective equipment/ items) for accumulating monitoring data as per the specification requirements for switchyards., surge arresters, 220 kv la, 132 kv la, 33 kv la, substation lt transformer, 33/ 0.433 kv, 250 kva lt transformer complete with all accessories, fittings, terminal connectors etc as specified filled with transformer oil, batteries & battery charger, batteries (sizing shall be as per requirement of technical specification), 220 v [min. 600 ah], 48 v [min. 600 ah], battery charger system, 220 v float and boost, 50 v float and boost, lighting system, outdoor lighting & other works, lighting fixture type fl-1, lighting fixture type fl-2, outdoor receptacle, type-rp, type-ro, substation premises lighting, lighting poles, type-l1, type-d1, street lighting type-sl-l1 for mounting on poles, street lighting type-sl-d1 for mounting on poles, sub-lighting boxes/panels type -slp at lighting mast and other loaction as designated complete with all controgears and accessories, items etc., lighting panel type acp-2 as per technical specifica
 Loading, Please wait...

Connect us via What's Up