Get complete information related to latest Motor Control Panel Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Motor Control Panel Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Motor Control Panel Tenders.
Tender For repair and replacement of lt distribution network system, unserviceable lt ug cable, lt joint finding faults, lt equipment, control gear, lt panel connected items including load balancing of external electric supplys at nasirabad mil station under ge
Tender For corrigendum : repair/ replacement and improvement of lt panel boards including control mswitch gears, earthing andunsv led fittings, internal wiring with mcb, mccb and misc e/m works at rrrc including training area, dk-i & dk-ii, aps colony and adjoining area under ge (central), delhi cantt -10
Tender For repairs/maint and cleaning of otm/jcos/ors sewage treatment plant incl pumps and motors, controlpanels,chemicals and connected works at jakli rc under ge 970 ews.
Tender For e-quotation for seeking firm rates for non-schedule items for preparing estimates. - s/i/t/c of new 80 hp vt pump set, supplying,installation,testing and commissioning of vt pumpset (confirming to is1710:2021 standards) with 35 ft suitable size ms column pipe assembly in random length of 5 ft.(make-jyoti/wpil/kirloskar) with ss/bronze impeller capable to discharge 216 m3/h against a total head of 68m coupled with vertical solid shaft tefc ie3,ip55 type squirrel cage induction motor (make-siemens/crompton/abb) operating on 3 phase 50 hz,415v+- 10% supply and having speed 1400-1500 rpm (bhp of motor should be 10% more than that of pumpset including cost pof supplying,fitting and fixing of all required accessories, repairing of 80 hp vt pump set at raw water, supplying all labour tools and tackles for taking out the 40hp vt pump set with bowl assembly, column pipe and line shaft etc., cost towards dismantling of complete bowl assembly., cost towards repairing and fitting the parts of vt pumpset as per requirement (works as complete overhauling of the pump) such as:-1.machining/lathe work 2.changing ss top shaft,line shaft(2 nos of 5 feet) of and bottom shaft2.repairing of bowl assembly and impleller3.supplying and fitting c.l spider bearing with rubber cut less bush-4nos4.supplying and fitting of worn-out nut-bolts,bolt-nut washer,gland body bush machining,other machining works,etc as per requirement, complete assembling the pump set and lowering including supplying all petty materials., cost for supplying and installation of required accesories for repair and maintenance of motorcontrolpanel such as:-150 amp contactor-2 no (for 1 no starter)160 amp,breaking capacity -36ka mccb 1 no56-90 a electronic overload relay-2 nostimer-2 nosvolt meter 1 nosamp motor 1 nospilot lamp 6 nosselector switch 4 nossingle phase preventer 2 nos[ all accessories of reputed make]with complete internal wiring with suitable size of copper wire and testing on load., repairing of 30hp c/f pump sets at clear water, cost for dismantling of 30 hp c/f and pump inspection,changing of its damaged parts such as:-key-01 no, gland tightner -1 set, gland tightner stud-2 nos, c.i bearing housing with cap -1 set, ball bearing 6306 (skf)-2 nos, grease, gland packing,maching of the pump parts as per required etc all complete and testing on load etc., cost towards complete repairing of motorcontrolpanel starter 30hp cf pump set opening and changing of damaged parts such as 1.mccb - 50 amp,25ka,3pole-2 nos (for motor backup protection),mccb -100 amp,50ka,3pole-1 no (main mccb)2.overload relay 26-40 amp-1no3.star delta timer-1no4.digital volt meter,ampere meter,three pahse indicator lamp,push button on/off,on/off/trip indicator,wiring,etc as per required, repairing of 15hp c/f pump sets at clear water, cost for dismantling of 15hp c/f and pump inspection,changing of its damaged parts such as:-key-01 no, gland tightner -1 set, gland tightner stud-2 nos, c.i bearing housing with cap -1 set, ball bearing 6306 (skf)-2 nos, grease, gland packing,maching of the pump parts as per required etc all complete and testing on load etc., cost towards complete repairing of motorcontrolpanel starter 30hp cf pump set opening and changing of damaged parts such as 1.mccb -25 amp,15ka,3pole-2 nos (for motor backup protection),mccb -50 amp,25ka,3pole-1 no (main mccb)2.overload relay 20-25 amp-1no3.star delta timer-1no4.digital volt meter,ampere meter,three pahse indicator lamp,push button on/off,on/off/trip indicator,wiring,etc as per required
Tender For annual rate contract for repair of lt controlpanel installed at various tube wells dug wells pumping stations in jal shakti phe division akhnoor - annual rate contract for repair of lt controlpanel installed at various tube wells/dug wells/pumping stations in jal shakti (phe) division akhnoor.
Tender For corrigendum : providing of custom bid for services - providing and fixing of miscellaneous spares for repairing of different lt motorcontrolpanels and mobile crusher panel of chp phase - i at kusmunda ocp
Tender For corrigendum : repair and replacement of lt distribution network system, unserviceable lt ug cable, lt joint finding faults, lt equipment, control gear, lt panel connected items including load balancing of external electric supplys and repair/ replacement / mainten - repair and replacement of lt distribution network system, unserviceable lt ug cable, lt joint finding faults, lt equipment, control gear, lt panel connected items including load balancing of external electric supplys and repair/ replacement / maintenance of street lights, security lights, timer switch and connected work at ajmer mil stn under ge nasirabad
Tender For corrigendum : repair replacement and rewinding of submersible pump centrifugal pump and repair replacement of motorcontrolpanel including supply of chemical for water supply instllations and swimming pool under ge mh and rh khadki
Tender For replacement of rubber seal and repair of motor, controlpanel and general maintenance of 04 nos. hr gate size (2.4 x 5.5) mtr. of mahana tunnel gate.