Web Analytics Made Easy - StatCounter

Motor Protection Spares Tenders

Get complete information related to latest Motor Protection Spares Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Motor Protection Spares Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Motor Protection Spares Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government And Public Sector

CTN :38587336 Due date: 28 Dec, 202428 Dec, 2024 8.22 Lacs
Tender For customized annual maintenance contract (amc) / comprehensive maintenance contract (cmc) for pre-owned products - amc; zeiss; annual maintenance contract (amc); quarterly; no; 1. routine maintenance, performance checks, re-alignment, repair and replacement of defective components and parts-hv cable assembly, ex mva "x" part-no.: 311311 -orsay , ex mva "y", valve assembly, spare assembly, o-ring iso valve, electro valve, 20 kv high voltage module, leader card holder, pneumatic actuator set, apertures assembly, o-ring for nozzles block, o-ring for aperture drive, steppermotor driver 51xpack2 /trinamic, gis psu, actuation cylinder complete, connector, nozzle head complete, high voltage module, grounding module f/liner tube lens, floater 300v, 0,5a 3/4", ex eht digit. controlled tetrode supply, xb scan piggy board, scan-generator, complete (auriga), e/o board hw4.0(3.5) with fw3.1.0, ex vac.-control board leo 15xx "stan dar, interlock piggy (mod. version), needle valve piggy with mounting parts, vac relay pcb (1400), main psu, fib-electronic pcb complete, deflector amplifier, internal generator, 6 hole aperture, pre-aperture 3h6x0,25/ 0,110mm, anode screw din 7984 m4x6 e, helicoflex-hnv-120-19,7-23,7-2-alu a5, copper gasket, spring+spool f/y axis assy, power supply tpsll0 /pfeiffer vacuum, compact fullrange gauge pkr 251, scintillator assembly, mikro-magnetventil 24 vdc, control pcb water chiller, ion pump, 30l/s noble pump, exhaust, ion pump kit (ion pump+dn35cf) -orsay , ion pump psu(neg) to 910846 1p100/702/02, tip seal kit for nxdsloi pump, illumination assy infrared,compl., spanner wrench, scintillator-changer, pcba 3-channel controller w/rs232, vp holder for 6 hole aperture l00na, extractor - aperture, denka kathode tfe 174c, transmitter extractor voltage, vat civ valve upgrade kit ose au/u/vp, servicepackage hipace 300 plus ose, se-multiplier, complete, pcba 3-channel controller w/rs232, ads 3 jsr m/s repair-kit, membrane f. isol-use# 348201-8902-910, motor assy, step, uhv,sd,1.0a, y-motor assy,step,uhv,sd,1.8a, r motor assembly pllo motor, vac relay pcb (1400), x-spring assembly spool + spring, install.kit for opt. sensor (le-geu-017), on/off-switch complete with pcb, airlock window, pcb for water chiller, asb-detector diode at objective lens, zylinderschraube 2 din912-m4x6, longetterpump 20l, copper sealer dn 40 cf cu pf501404-t, ex fib hv cable assy -orsay , 90u anode aperture, unloader valve for jun air compressor, chiller water pump, van der heijden, water chiller air cooled type, 12v 42ah smf battery for lokva ups, gallium source, gallium source refilled, liner tube assy, fib aperture set 50u,20u,50u,100u,200u,400u, copper gasket for gallium emitter, compressor pi-120-25, 230/50-60hz, dry backing pump system nxdsl0i, set anode screws m4x6 din7984 8x, reservoir pt, cable for penning (new pfeiffer), ex controller f/steerer, ex pcba stage controller, joy stick, controller -2. to keep the equipment in up to-date condition during the period of the contract.-msme exemption - no | startup exemption - no,

Central Government/Public Sector

CTN :38157116 Due date: 27 Dec, 202427 Dec, 2024 1.30 Crore
Tender For corrigendum : special repair for renewel of e/m items and plant/ machinery held in charge of age (e/m) rnd agra cantt under ge (i) rnd delhi - supply , installatation , testing and commissioning of diesel driven generating set to give an out put of 500 kva, 415v ac supply 3 phase, 50 hz, 4 wire radiator mounted on common base plate complete with fuel tank, vibration damper and other accessories with fuel tank viberation damper and other accessories with acoustic enclouser as per latest cpcb-iv norms and amf panel including pcc foundation work as per oem reccommandation and taking out the old dg set from the location and deposited to mes store yard complete all as specified and directed, interanally comprising of following :-(a) diesel driven engine :- developing a net output suitable matched to give a net rated output of minimum 604 hp/suitable to drive 500 kva alternator, at 0.8 power factor 415 volts. the engine should be capable of delivering the required output at 1500 rpm, water cooled, self start, with a provision of 10% overload for one hour in every 12 hours with the following accessories and all as specified.(i) fly wheel to suit flexible coupling and fly wheel housing.(ii) air cleaner complete as per manufacturer specification. (iii) fuel injection pump. (iv) flexible coupling with guard, nuts and bolts.(v) fuel filter with mounting. (vi) oil filter with mounting.(vii) starter motor as per manufactures design.(viii) exhaust, silencer industrial type with exhaust pipe suitable length.(ix) batteries 12 volts 2x180 ah maintenance free batteries with copper lead, terminals etc.(x) instrument panel complete with microprocessor based controller comprising shut down valve indication, lcd hour counter indication, rpm indication , led lamps for fail to start, over speed /under speed . low lub oil pressure, high engine coolant temperature. gaugae.(xi) dynamo/alternator suitable rating., (b) alternator :-the above engine will be coupled through flexible coupling on an indigenous alternator mounted on a strong steel fabricated common base frame suitable for mounting in an acoustic enclousre. the alternator will be 3 phase 50 hz 1500 rpm self regulating self exciting type and have class h insulation of stator and rotor windings and generate 500 kva output at .8 power factor 4 wire 415 volts ac supply under ntp condition with a provision of 10% overload for 1 hour in every 12 hrs running. the alternator would be screen protected and fitted with shield ball/roller bearing, automatic voltage regulator.(c) control panel :- s&f amf (automatic on mains failure) control panel cpri approved outdoor ype kiosk water, dust and vermin proof and fabricated out of 3.15 mm thick crca sheet and 50mm x 50mm x 6mm angle iron powder coated suitable for 415 volts 3 phase 50 hz ac supply with and incl the following :-(i) mccb of suitable capacity(ii) necessary relays, times and power contractors of suitable rating/capacity for auto on-off the dg set and changeover of the load in case of power failure.(iii) digital mulfifunctional meter for phase wise reading of amps, voltage kwh and frequency -01(iv) internal wriring with single core solid copper conductor cable of appropriae gauge incl mumbering ferrules and control fuses.(v) earthing terminals 02 nos(vi) auto/manual start switch to by pass auto start.(vii) battery charging system suitable for charging for charging the battery provided with the dg set incl boost/stickle switch and system, dc voltmeter digital type., (d) fuel tank :- one no built in sheet metal steel tank mounted inside the acoustic encloser and of adequate capacitynot less than 740 ltr with inlet and outlet connection including the following :-(i) level indicator with float and gauge.(ii) fuel piping for fuel supply to engine and over flow to tank(iii) fuel strainer(e) acoustic enclosure :- enclousre be designed for reducing the sound level up to 75+/ 5db (average) as per is 8528 part 10 and as per approved cpcb morms. the acous
 Loading, Please wait...

Connect us via What's Up