Get complete information related to latest Mri Machine Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Mri Machine Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Mri Machine Tenders.
Tender For providing of customized amc/cmc for pre-owned products - camc of mrimachine on turnkey basis; philips achieve 15t mri system; comprehensive maintenance contract (cmc); 02 times every 06 months; yes
Tender For corrigendum : annual preventive / breakdown maintenance of equipments at 220/132/33kv substations under 220kv oandm division rishikesh - 220 kv switchyardtightening of 220 kv bay equipments (cb, line isolator, transfer isolator, ct, cvt and la including all connectors of droppers/runner/jumpers), cleaning of 160 mva transformer by cleaning of whole body, accessories alongwith tightening of bushing connectors, earthing, proper cleaning of cooling system, replacement of silica gel etc.complete, cleaning of 220 kv circuit breaker by cleaning of whole body including marshalling box alongwith tightening of connectors, earthing, proper cleaning of poles and assistance in testing work, overhauling of mechanism of 220 kv isolator with cubicle including cleaning, lubrication and proper alignment., cleaning of equipments porcelain/polycon (i.e.cb/ct/cvt/la/isolator/bpi) with clean cotton cloth complete, replacement of conductor jumpers/runner/dropper etc. including connectors/clamps, cutting /drilling of holes in clamps, replacement of 220 kv terminal connector/clamp/jaw/blade etc. and tightening of related equipment (including replacement of minor conductor segment/patch), replacement of 220 kv take-off assembly/ moving head assembly/rotary head devive etc. (including proper alignment) complete, unforseen work/maintenance of equipments/panels etc including tracing of fault &remidial action as per direction of site engineer, topping up of sf-6 gas in 220 kv circuit breaker/ oil in ct & cvt under breakdown/preventive maintenance (including shifting of gas cylinder/oil drums), repairing of hpsv lamp fittings/replacement of led fittings at 220 kv switchyard., 132 kv switchyardtightening of 132 kv bay equipments (cb, line isolator, transfer isolator, ct, cvt and la including all connectors of droppers/runner/jumpers), cleaning of 132 kv circuit breaker by cleaning of whole body including marshalling box alongwith tightening of connectors, earthing, proper cleaning of poles and assistance in testing work., overhauling of mechanism 132 kv isolator with cubicle including cleaning, lubrication and proper alignment., cleaning of equipments porcelain/ polycon (i.e.cb/ct/cvt/la/isolator/bpi) with clean cotton cloth complete., replacement of conductor jumpers/runner/dropper etc. including connectors/clamps, cutting /drilling of holes in clamps, replacement of 132 kv terminal connector/clamp/jaw/blade etc. and tightening of related equipment (including replacement of minor conductor segment/patch), replacement of 132 kv take-off assembly/ moving head assembly/rotary head devive etc (including proper alignment) complete, unforseen work/maintenance of equipments/panels etc including tracing of fault &remidial action as per direction of site engineer., topping up of sf-6 gas in 132 kv circuit breaker/ oil in ct & cvt under breakdown/preventive maintenance (including shifting of gas cylinder/oil drums), repairing of hpsv lamp fittings/replacement of led fittings at 132 kv switchyard., 33kv switchyard:tightening of 33 kv bay equipments (cb, line isolator, ct including all connectors of droppers/runner/jumpers), cleaning of 40 mva transformer by cleaning of whole body, accessories alongwith tightening of bushing connectors, earthing, proper cleaning of cooling system, replacement of silica gel etc.complete, cleaning of 33 kv circuit breaker by cleaning of whole body including marshalling box alongwith tightening of connectors, earthing, proper cleaning of poles, assistance in testing work., overhauling of mechanism 33 kv isolator with cubicle including cleaning, lubrication and proper alignment., cleaning of equipments porcelain/ polycon (i.e.cb/ct/cvt/la/isolator/bpi) with clean cotton cloth complete, replacement of conductor jumpers/ runner/ dropper etc. including connectors/clamps, cutting /drilling of holes in clamps, replacement of 33 kv terminal connector/clamp/jaw/blade etc. and tighgtening of related equipment (including replacemen
Tender For corrigendum : shifting ups of medical equipment mri x ray ct scan and fluoroscopy from ups room inside wing c ground floor to outside from building at hbchrc, new chandigarh
Tender For supply and fitting of safety equipment in three (03) nos. of ece make ocb for compliance of dgms violation in compressor section of moonidih project, wj area. sl.no. comp no. 1,3,10 - supply and fitting of safety equipment in three (03) nos. of ece make ocb for compliance of dgms-violation in compressor section of moonidih project, wj area. sl.no. comp no. 1,3,10., digital earth leakage relay, 30ma-30a, auxiliary supply:110- 240v ac/dc, highly sensitive cbct using nanocrystalline core, id-120mm, electronic motor protection relay (multi protection functions), manufacturing and providing of moulded heavy ct with 500/5 a ratio for both protection and metering, manufacturing and providing of pt 550v/220v/110v, push switch with element, kit kat fuse with carrier, make-bussmann/eation, tripping coil 220vac with plunger set, copper wiring wire, ferule, tie & lugs etc., technical charge/labour charge for wiring, buzzer with led indication 220v, painting of switch, testing transformer, total impact of gst for the purpose of ctc
Tender For nit for supply, installation, operation and maintenance of 128 slice ct scanner machine and 1.5 tesla mrimachine on ppp mode at ruhs hospital, jaipur
Tender For supply of required maintenance of 33 kv equipment isolator ct c b etc at 220 kv substation panki, kanpur under 220 kv sub station division panki kanpur
Tender For corrigendum : tender for supply of equipment design erection tetsing and commissioning for sop to 4g bsnl tower authority by providing single phase lt line at lagga chalga along with augmentation of existing dtr under esd chamba no ii - supply of lt line with acsr 6/1/2.59 mm sq. on steel poles (0.060 km)vill. lagga and aug. of 11/.4 kv 25 kva to 63 kvs s/stn. lagga section sahoo esd chamba-ii t.s.no. 97/24-25), acsr 6/1/2.59 (30mm ) {includes 2 conductor lengths for 1 and additional 1% (sag, jumpering and wastage}, prov. steel tubular poles.8mtrs, muff for steel tubular pole (1800mm long) with concrete filling, shackle insulator with d-iron, stay set complete in all respect, stay wire (7/3.15 mm) (8.0 kg per stay set), prov. g.i. wire 8swg, prov. egg insulator, prov. eye hook, nut & bolts off size, aluminium paint, erection of lt line with acsr 6/1/2.59 mm sq. on steel poles (0.060 km)vill. lagga and aug. of 11/.4 kv 25 kva to 63 kvs s/stn. lagga section sahoo esd chamba-ii t.s.no. 97/24-25), acsr 6/1/2.59 (30mm ) {includes 2 conductor lengths for 1 and additional 1% (sag, jumpering and wastage}, prov. steel tubular poles.8mtrs, muff for steel tubular pole (1800mm long) with concrete filling, shackle insulator with d-iron, stay set complete in all respect, stay wire (7/3.15 mm) (8.0 kg per stay set), prov. g.i. wire 8swg, prov. egg insulator, prov. eye hook, nut & bolts off size, aluminium paint, supply of aug. of 11/.4 kv 25 kva to 63 kvs s/stn. lagga, prov. 11/.4 kv, 63 kva s/stn., pipe earthing with gi,charcoal & salt, prov. lt distribution panel with mccb (160 a, 10 ka, 4p,1 no.) & sfu (32 a 5 no. rewireble) for 63kva trf. as per specification, lt cable 3-1/2 core-70mm sq., surge arrester, 9 kv station class, aluminium thimbles, copper thimble, energy meter (3-phase, 4-wire) dlms compliant 1000/5 a ct type for 63 kva transformer, erection of aug. of 11/.4 kv 25 kva to 63 kvs s/stn. lagga, prov. 11/.4 kv, 63 kva s/stn., pipe earthing with gi,charcoal & salt, prov. lt distribution panel with mccb (160 a, 10 ka, 4p,1 no.) & sfu (32 a 5 no. rewireble) for 63kva trf. as per specification, lt cable 3-1/2 core-70mm sq., surge arrester, 9 kv station class, aluminium thimbles, copper thimble, energy meter (3-phase, 4-wire) dlms compliant 1000/5 a ct type for 63 kva transformer, mannual carriage of existing & new transf.(25 & 63 kva) 2.00 km back to store, supply of lt line with acsr 6/1/2.59 mm sq. on steel poles (0.650km) vill. chalga section chaned esd chamba-ii t.s.no.96 /24-25), acsr 6/1/2.59 (30mm ) {includes 2 conductor lengths for 1 and additional 1% (sag, jumpering and wastage}, prov. steel tubular poles. 8mtrs, prov. steel tubular poles. 9mtrs, muff for steel tubular pole (2000mm long) with concrete filling, shackle insulator with d-iron, stay set complete in all respect, stay wire (7/3.15 mm) (8.0 kg per stay set), prov. g.i. wire 8swg, prov. egg insulator, prov. eye hook, nut & bolts off size, coil earthing, aluminium paint, erection of lt line with acsr 6/1/2.59 mm sq. on steel poles (0.650km) vill. chalga section chaned esd chamba-ii t.s.no.96/24-25), acsr 6/1/2.59 (30mm ) {includes 2 conductor lengths for 1 and additional 1% (sag, jumpering and wastage}, prov. steel tubular poles. 8mtrs, prov. steel tubular poles. 9mtrs, muff for steel tubular pole (2000mm long) with concrete filling, shackle insulator with d-iron, stay set complete in all respect, stay wire (7/3.15 mm) (8.0 kg per stay set), prov. g.i. wire 8swg, prov. egg insulator, prov. eye hook, nut & bolts off size, coil earthing, aluminium paint