Tender For corrigendum : supply of t&p material under dapoli-i subdivision of khed division - pp rope ", pp rope 1", hexa frame with steel blade, megger(5kv), tong tester 3.5 digit, the tong tester shall have the following parameters: a) ac current measurement: 0- 20/50/500/1000 amp b) ac/dc voltage measurement:- 0 to 300 v/600 v. c) resistance measurement: 400 ohms to 4 k ohms., accuracy: i) for ac current 3% reading with, resolution of 0.1 upto 100 a, 1.0 upto 500/ 1000 a. 2632_spec.doc 2 ii) for ac/dc voltage 1.5% reading with resolution of 0.1 upto 100 v, 1.0 upto 600 v. iii) for resistance 1% reading with resolution of 0.1 ohm upto 400 ohms, 0.1 ohm upto 4 k ohms., the meter should have 3-1/2 digits 2000 counts led display preferably with backlit., aluminium folding ladder (7/8 mtr), spanner set 8 - 24 nos double ended ring, adjustable spanner 12", adjustable spanner 6", collapsible ht earth rod for voltages upto 33 kv, taparia 2 in 1 screw driver 905 1, high beam torch led rechargable, come along clamp
Tender For corrigendum : supply of t&p material inder lote subdivision of khed division - pp rope ", pp rope 1", hexa frame with steel blade, megger(5kv), tong tester 3.5 digit, the tong tester shall have the following parameters: a) ac current measurement: 0- 20/50/500/1000 amp b) ac/dc voltage measurement:- 0 to 300 v/600 v. c) resistance measurement: 400 ohms to 4 k ohms., accuracy: i) for ac current 3% reading with, resolution of 0.1 upto 100 a, 1.0 upto 500/ 1000 a. 2632_spec.doc 2 ii) for ac/dc voltage 1.5% reading with resolution of 0.1 upto 100 v, 1.0 upto 600 v. iii) for resistance 1% reading with resolution of 0.1 ohm upto 400 ohms, 0.1 ohm upto 4 k ohms., the meter should have 3-1/2 digits 2000 counts led display preferably with backlit., aluminium folding ladder (7/8 mtr), spanner set 8 - 24 nos double ended ring, adjustable spanner 12", adjustable spanner 6", collapsible ht earth rod for voltages upto 33 kv, taparia 2 in 1 screw driver 905 1, high beam torch led rechargable, come along clamp
Tender For corrigendum : supply of t and p to khed subdivision - pp rope ", pp rope 1", hexa frame with steel blade, megger(5kv), tong tester 3.5 digit, the tong tester shall have the following parameters: a) ac current measurement: 0- 20/50/500/1000 amp b) ac/dc voltage measurement:- 0 to 300 v/600 v. c) resistance measurement: 400 ohms to 4 k ohms., accuracy: i) for ac current 3% reading with, resolution of 0.1 upto 100 a, 1.0 upto 500/ 1000 a. 2632_spec.doc 2 ii) for ac/dc voltage 1.5% reading with resolution of 0.1 upto 100 v, 1.0 upto 600 v. iii) for resistance 1% reading with resolution of 0.1 ohm upto 400 ohms, 0.1 ohm upto 4 k ohms., the meter should have 3-1/2 digits 2000 counts led display preferably with backlit., aluminium folding ladder (7/8 mtr), spanner set 8 - 24 nos double ended ring, adjustable spanner 12", adjustable spanner 6", collapsible ht earth rod for voltages upto 33 kv, taparia 2 in 1 screw driver 905 1, high beam torch led rechargable, come along clamp
Tender For corrigendum : supply of t&p material under dapoli-ii subdivision of khed division - pp rope ", pp rope 1", hexa frame with steel blade, megger(5kv), tong tester 3.5 digit, the tong tester shall have the following parameters: a) ac current measurement: 0- 20/50/500/1000 amp b) ac/dc voltage measurement:- 0 to 300 v/600 v. c) resistance measurement: 400 ohms to 4 k ohms., accuracy: i) for ac current 3% reading with, resolution of 0.1 upto 100 a, 1.0 upto 500/ 1000 a. 2632_spec.doc 2 ii) for ac/dc voltage 1.5% reading with resolution of 0.1 upto 100 v, 1.0 upto 600 v. iii) for resistance 1% reading with resolution of 0.1 ohm upto 400 ohms, 0.1 ohm upto 4 k ohms., the meter should have 3-1/2 digits 2000 counts led display preferably with backlit., aluminium folding ladder (7/8 mtr), spanner set 8 - 24 nos double ended ring, adjustable spanner 12", adjustable spanner 6", collapsible ht earth rod for voltages upto 33 kv, taparia 2 in 1 screw driver 905 1, high beam torch led rechargable, come along clamp
Tender For corrigendum : supply of t and p material under mandangad subdivision of khed division - pp rope ", pp rope 1", hexa frame with steel blade, megger(5kv), tong tester 3.5 digit, the tong tester shall have the following parameters: a) ac current measurement: 0- 20/50/500/1000 amp b) ac/dc voltage measurement:- 0 to 300 v/600 v. c) resistance measurement: 400 ohms to 4 k ohms., accuracy: i) for ac current 3% reading with, resolution of 0.1 upto 100 a, 1.0 upto 500/ 1000 a. 2632_spec.doc 2 ii) for ac/dc voltage 1.5% reading with resolution of 0.1 upto 100 v, 1.0 upto 600 v. iii) for resistance 1% reading with resolution of 0.1 ohm upto 400 ohms, 0.1 ohm upto 4 k ohms., the meter should have 3-1/2 digits 2000 counts led display preferably with backlit., aluminium folding ladder (7/8 mtr), spanner set 8 - 24 nos double ended ring, adjustable spanner 12", adjustable spanner 6", collapsible ht earth rod for voltages upto 33 kv, taparia 2 in 1 screw driver 905 1, high beam torch led rechargable, come along clamp
Tender For corrigendum : supply of electrical items like tester auxiliary contactor relay etc - hand driven generator type insulation tester meggar , tong tester digital clamp meter , digital earth resistance tester , analog hand driven earth resistance tester , portable type single phase inverter type welding machine , auxiliary contactor relay , potential transformer , main contactor , thermal overload relay , auxiliary contactor relay 220 volt , non contact type high voltage line detector , 2 pole mcb 20a , single pole mcb 6a
Tender For corrigendum : procurement of different tools and plants for repairing of distribution transformers at different trws under sbpdcl - welding machine 450 amps , chain pully block 3 mt cap. , chain pully block 5 mt cap. , fire extinguisher 10kg (carbon dioxide) , fire extinguisher 10kg (foam type) , megger (hand driven) 5kv/5000m? , ratio meter (non-automatic) , winding resistance test meter , drill machine 1" , tripod 16? for lifting , electronic multimeter , electronic tongue tester , sling rope with d shakle ? diax7? length , sling rope with d shakle ? diax7? length , ms trolley (6?x3?size) mounted on 4 nos. iron wheel , high voltage testing machine , hydrolic hand pallet truck 3 mt , weighing machine capacity 1 ton , 52" table mounting hand operated press board cutting machine with all accessories , dpc strip covering machine single head
Tender For supply of supply of (e&m) item-, supplying of one number 3.5c x 300 sq.mm pvc insulated and pvc sheathed/xipe al. armoured conductor power cable of 1.1 kv grade of following ways complete etc as reqd., supplyof 2 kg hfc 227 ca/fk-5-1-12 with 10 mtr minimum heat sensing tube fire suppression system. clean agent hfc 227 ca/fk-5-1-12 dlp (direct low pressure) with zero ozone depletion potential. container along with valve assembly: clean agent hfc 227 ca/fk-5-1-12 direct complete as reqd operating pressure is 15 bar at 20 degree. sensor tube automatic fire suppression system, made by special modified polyamide double layered color blue/black/red, high grade hr quality, stabilized, inner diameter 4mm.outer diameter 6mm, sensor tubing hr blue/black/red in mtr. senso tube uv resistance with pressurization of tube using nitrogen gas. the hst conductive, non-corrosive and flexible. operating pressure: 15 bar end of line plug-maximum working pressure 20 bar. t connections., pressure switch. pressure valve - direct low pressure type with inbuilt pressure gauge, integrated ball valve for open/ close within the valve body. reed switch to monitor the valve position using the reed switch relay to indicate valve open/close position. power back up for monitoring panel- 12v, 7.2 ah smf batteries (2 nos) end line adopter. 2x1.5 sq. mm pvc insulated pvc seethed copper conductor single core cable wire in meter. required compelete system certification that is equivalent to lpcb standard equivalent to lps 1666: issue 1.0 with indian nabl. lab report., supply of low pressure is 16018 45 itr trolley mounted water mist & caf fire extinguisher with following specifications: water mist & caf fire extinguisher having fire rating 204, 2338 and dielectric test on is: 16018: 2012 (c1.6.8) 36kv at 1 meter distance, with standard afff 3% compound, confirming to is 4989. extinguishing gun stainless steel 1-2 kg approx weight with nabl test report. dual nozzle jet mode to spray mode by twisting of nozzle. suitable for all classes of fire a. b and e. pressure vessel with 45 liter nilling capacity. compressed air cylinder 6 liter 300 bar cylinder which can be inounted on universal air cylinder holder capable of holding these cylinders, length of hose 5 meter, the cylinder should be of red color with powder coating as per is standards the paint should confirm to is: 5:2007 shade 538., cylinders. lancing distance of gun 3-15 meter, flow rate 42 to 50 liter per second. system test: tested from nabl lab/erda, 1) content-water, foam, 2) gun mode jet and spray., supply & foxing of 100 watt led highway light suitable for 120 to 300v of cct(k) $700 lumen efficacy >130, cri minimum 70, mech, impact protection code above ik.08 having pic housing luminaire for enhanced uniform illumination and with ip66/65 protection i/c connection ete complete as reqd.,