Get complete information related to latest Needle Valves Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Needle Valves Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Needle Valves Tenders.
Tender For corrigendum : supply of repair and rewinding e e - opening of transformer cover draining oil de-tanking core- coil assembly assessment and estimation for repair and replacement of parts providing locking arrangement of all valves and plugs , loading and unloading of transformer at side cph and firms work premises hiring , hv leg coil with insulation varnish and baking of coil assembling vacuum , lv leg coil with insulation varnish and baking of coil assembling vacuum impregnation new ec grade copper with insulation , set of gaskets rubberized cork neoprene material and size is needed for hv and lv , breather dehydrator silica gel type with fresh silica gel 01 kg , fresh transformer oil of standard quality as per the isi mark for main tank and oltc , double float buchholz relay including all accessories , air release valve including all accessories if required , magnetic oil gauge including all accessories if required , radiator valve including all accessories if required , reassembling of 3 15 mva transformer dyn 11 star delta connected with proper size of copper strip , replacement change of complete gaskets rubberized cork neoprene material , the oltc was completely repaired with the replacement , painting charges of transformer tank having hot oil resistant paint inside and synthetic enamel paint on transformer after cleaning of tank and complete painting outside etc as reqd. , less the cost of old and burned transformer oil plus old transformer oil of oltc , less the cost of old and dismantling insulated copper
Tender For corrigendum : supply of sch viii (supply of needle & syringes) - sch viii (supply of needle & syringes), disposable needle sterile length 1/2" guage 25, suture needle, half circle triangular nos. 2 to 20 (cutting), insulated needle for use with peripheral nerve stimulator 22g x 2" x 50 mm., insulated needle for use with peripheral nerve stimulator 22g x 35 mm., insulated needle for use with peripheral nerve stimulator 24g x 1"x 25 mm., echogent needles for usg guided peripheral nerve blocks 20g / 21g x 100 mm., echogent needles for usg guided peripheral nerve blocks 22g x 50 mm., epidural needles 16 & 18 guage 7.5cm to 11cm (disposable), epidural needles (long length) 18g (more than 100 mm. length), sterile disposable lancet size 28-32 (plastic lancet needle type), sterile disposable hypodermic plastic syringe 20cc, cn. with leur lock, hypodermic syringes,disposable sterile, sterile pack,with/without leur lock, hub 1ml syringe with marking at 0.1 ml, asepto syringe 100 ml of heavy plastic barrel and rubber bulb with marking., bag arm rubber with cover for b.p. apparatus, adult size velcro.rubber bag size 13 x 23 cms., keratome, size 2.8 mm, type-regular(ophthalmic), angle-45 degrees, bevel type- bevel up (pointed)blade-stainless steel/carbon steel,handle- polycarbonate, use- disposable single use, mvr, gauge 23g type-regular(ophthalmic), blade-stainless steel handle- polycarbonate, use- single disposable use, triple lumen catheter 7.5fr with 14g distal lumen, length-15cm. kit contain 1 teflon-coated j nitinol guidewire particularly kink-resistant with guide-advancer. 1 dilator, 10cm long, 3 injection caps, 3 clamps,1 supplementary fixation wing,1 scalpel, 1 syringe 5 ml, 1 adaptor for pressure transducer, 1 puncture needle 18g, 70mm long with a pre-connected valve to aviod air embolism and blood loss, 18g short iv cannula, double lumen subclavian/ jugular catheter kit (adult) ptfe (teflon) cannula curved od 2.7/d 11.5fr-12fr/chx5.3in. (3.8 mm x 13.5 cm) 6 side holes silicon tube s clamping extension, clamp luer lock "y" connector with protective caps size 12.5, 15 with guide wire introducer needle, dialator , 3fr double lumen cvc catheter with 60mm double-lumen polyurethane central venous catheter inserted by seldinger technique, radio opaque material for catheter, the user should be able to choose from 2 type of introducer, i.e.needle 23g or i.v. cannula 22g, latex free, the central venous catheter set should contain: 1 double-lumen polyurethane 3fr catheter, 1 short i.v. cannula 22g, 1 introducer needle 23g, 1 kink resistant guidewire with soft flexible tip, dilator with cylindrical /pencil point tip, 1 secondary fixation wing, 2 injection caps, 1 scalpel, 1.5 ml syringe, peripherally placed radiopaque central single lumen catheter. guage 14/16 (100%) (needles size/catheter size) length - 55cm - 70cm, peripherally placed radiopaque central single lumen catheter. guage 18/20 (100%) (needles size/catheter size) length 30cm - 45cm, fully radiopaque pur catheter 16g for femoral artery centimeter marking from 5-15cm, winged hub for skin fixation, supple distal tip. kit should contain 1 pur catheter with xro lines,1 puncture needle, 1 j guidewire with wishbone-type guidewire advancer, 1 dilator, radial/femoral arterial pe catheter with antikinking collar & fixation wings,straight guide wire, introducer needle.catherter size g- 18, length 10cm, radial/femoral arterial pe catheter 20g, 8cm puncture needle is fitted with a visualization chamber allowing to confirm that the vessel punctured is an artery (pulsatile movement of the blood). the needle is also fitted with a silicone bloodless system valve to avoid loss of blood during vessel puncture and a funnel hub to facilitate the insertion of the guidewire, peripherally inserted central catheter with guide wire with peelable cannula, made of polyurethane, non-toxic, with radio opaque line throughout the catheter with marking every cm with leur connector at proximal en
Tender For corrigendum : supply of drilling spare parts and conventional rig pump spares d d ? g? g - nq locking and guide coupling , nq innertube latch with spring , nq overshot latch with spring , nq shutoff valve nylon material , nq landing ring , t6 bearing , t8 bearing , t10 bearing , nq pin to nw pin adapter for hoisting plug , wash pipe for high speed water swivel , packing for high speed water swivel set of five , o ring for high speed water swivel , spring for high speed water swivel , nw pin to nq box adapter for tape , heavy duty u clamp 19 mm , nq hydraulic chuck jaw set of 04 for rd100 , chuck pinion with screw for rd 100 , hydraulic chuck t bolt , heavy duty u clamp 22 mm , water swivel packing 81 mm nylon , wash pipe for conventional water swivel , wireline clutch finger set complete assy , hydraulic fixed cylinder check nut gunmetal or brass , hydraulic feed control valve , hydraulic main pressure valve , gps 125 mud pump liner , gps 125 mud pump piston rod , water pressure guage for mud pump 6 inche dial size , hydraulic pressure gauge 6000 psi , hydraulic fixed cylinder bucket ) /bid number : gem/2026/b/7459176 * /dated: 21-04-2026 & & / bid document 1 / 32
Tender For supply of dv air station and lpg line : : - flp 3 by 2 solenoid valve with coil 24v dc , flp pressure switch , flp pressure transmitter , thermal relief valve , pressure gauge 0 to 7 kg per cm2 range , pressure gauge 0 to 14 kg per cm2 range , filter regulator lubricator frl unit
Tender For corrigendum : supply of spares for pneumatic rosov - seal kit 12 inch , air filter regulator , limit switch , supply and fixing ss pnuematic air tube with fittings , air breather 1 inch , 230 volt coil in sov , seal kit 18 inch , pressure gauge for afr , flow control valve fcv , air breather half inch , seal kit 24 inch , seal kit 16 inch , seal kit 8 inch , seal kit 28 inch
Tender For bid to ras supply of vessel body high pressure cv as per spec. no. hemrl/inst/cv/2025/hpcv/01 , water circulation jacket as per spec. no. hemrl/inst/cv/2025/hpcv/01 , liner high pressure cv as per spec. no. hemrl/inst/cv/2025/hpcv/01 , firing block high pressure cv as per spec. no. hemrl/inst/cv/2025/hpcv/01 , gauge block hpcv as per spec. no. hemrl/inst/cv/2025/hpcv/01 , release valve assembly hpcv as per spec. no. hemrl/inst/cv/2025/hpcv/01 , firing electrode hpcv as per spec. no. hemrl/inst/cv/2025/hpcv/01 , gauge electrode hpcv as per spec. no. hemrl/inst/cv/2025/hpcv/01 , sealing ring hpcv as per spec. no. hemrl/inst/cv/2025/hpcv/01