Get complete information related to latest Network Equipments Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Network Equipments Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Network Equipments Tenders.
Tender For supply of integrated queue management terminal unit , system installation and commissioning service , display and notification interface system , connectivity and network integration module , software configuration and control interface
Tender For supply of 55 inches video wall panel display unit with push bracket wall mount , surveillance system to distribute across 4 video display control unit , customised wooden fabrication work , centralisation horizontal double mounting siren 5 km , centralisation horizontal double mounting siren operates from 2 location switch control unit with armoured cable 4 core 3 sq mm 3 phase line power cabling piping and installation , poe gigabyte switch with 2 sfp modular , dual location displayunit operating system with wire mouse , installation of networking system configuration network cablling as per power cabling total entire setup
Tender For supply of digital queue management and customer flow control system procurement package : : - integrated queue management terminal unit , system installation and commissioning service , display and notification interface system , connectivity and network integration module , software configuration and control interface
Tender For tender for supply of radiation resistant cctv camera : : - type-ii (color ccd/cmos , 100m rad) radiation resistant camera head along with radiation resistant pan & tilt unit and mounting brackets. as per attached annexure-1 , corrigendum annexure-2 and annexure-3. , cabling system to transmit signals form vault cameras to ccu system which includes camera to ccu radiation resistant composite cable of 300 meters with 6 sets of cable connectors and applicable power cables as per annexure-1 , corrigendum annexure-2 and annexure-3. , field camera control unit and its racking system which includes 2 no. of camera control unit sub rack & 6 sets of camera control unit (ccu) cards (3 to be installed in field and 3 to be kept as spare for future ) as per annexure-1 , corrigendum annexure-2 and annexure-3 or equivalent sub rack system as per annexure-1 , corrigendum annexure-2 and annexure-3. , setup to convert ccu signals to optical signals which should include 3 no. of fiber optic transmitter and receiver set (capable of 4 camera system) and 6 no. of fiber patch cords , single mode , simpex and 3 no. of light interface unit 12 port , as per annexure-1 , corrigendum annexure-2 and annexure-3. , type-vi (color ccd/cmos sensor , non rr auto dome camera) with mounting brackets as per annexure-1 , corrigendum annexure-2 and annexure-3. , mechanism to transmit signal from non radiation resistant camera including , poe power supply for non-rr ptz camera (6 no.) field jb /rack in ss material for non-rr ptz camera (2 no.) liu 6 port , din rail mountable for non radiation resistant ptz camera (3 no.) din rail 8 port un-managed network switches (3 no.). 4 no. of fiber patch cords , single mode , duplex for non-radiation resistant ptz camera or equivalent as per annexure-1 , corrigendum annexure-2 and annexure-3. , mechanism for receiving signal at control room including light interface unit 24 port , rack mount (2 no.) and network video encoder (minimum 16-channel) along with accessories for intra-panel connections (2 no.) and 24 port un-managed network switches or equivalent (2 no.) , 4 no. of fiber patch cords , single mode , duplex as per annexure-1 , corrigendum annexure-2 and annexure-3. , recording and monitoring pc as per annexure-1 , corrigendum annexure-2 and annexure-3. , joystick suitable for mounting on control room panel cutout as per panel drawing as per annexure-1 , corrigendum annexure-2 and annexure-3. , 21 inch led backlit led color monitor as per annexure-1 , corrigendum annexure-2 and annexure-3. , video monitoring software setup as per annexure-1 , corrigendum annexure-2 and annexure-3 for minimum 9 camera. , mobile dolly consisting of camera control unit (ccu) , encoder , switch , joystick , engineering laptop with 15-inch to 17-inch screen , video management software for one camera , connection cables etc and their cabling as per annexure-1 , corrigendum annexure-2 and annexure-3. , control panel/rack 42u/ 27u setup for racking all instruments of cctv at control room as per annexure-1 , corrigendum annexure-2 and annexure-3. , cabling network optical fiber cable (6 core armored cable)-2000 meters twisted pair cable , rs485 , signal cable -200 meters unarmored coaxial cable rg59 -200 meters ethernet cable , cat-6 utp cable -610 meters video connector set -10 meters ethernet connectors rj-45 100 pieces conduit for cables 800 meters and other separate cables/ power cables/accessories required during installation one set of tool tackles for assembly/ disassembly/ of radiation resistant camera head viz. allen keys , lubricants , cable ties , loctite , heat sink , blank caps etc. 2 no. of control panel/rack size 27u setup for racking all instruments of cctv at field as per annexure-1 , corrigendum annexure-2 and annexure-3. as per annexure-1 , corrigendum annexure-2 and annexure-3 . , site installation & commissioning as per annexure-1 , corrigendum annexure-2 and annexure-3. , spare radiation resistance camera head s
Tender For corrigendum : rate contract tender for supply, installation and commissioning of ups systems,batteries, enterprise networking equipments, networking components through elcot angadi e commerce portal - rate contract tender for supply, installation and commissioning of ups systems & batteries, enterprise networking equipments, networking components through elcot angadi e-commerce portal
Tender For corrigendum : comprehensive annual maintenance of existing lan networking, cctv surveillance, wi-fi, networkequipments, video conference equipment, online ups and optical fiber cable backbone with internet 50 mbps leased line for btda campus for all office building. for year 2026-27 on turnkey basis
Tender For corrigendum : supply of e4253023 numerical relays sas items other accessories for ntpc singrauli project c c - e4253023 numerical relays 01-sg4945037000-numerical main-1 generator protection relay as per it-01 of ann-1 , 02-sg4945037019-accessories for sef and ref as per it-02 of ann-1. , 03-sg4945037027-numerical main-2 generator protection relay as per it-03 of ann-1 , 04-sg4945037035-numerical transformer differential 3 wdg protection relay as per it-04 of ann-1 , 05-sg4945037043-numerical overall differential protection relay as per it-05 of ann-1. , 06-sg4945037051-numerical overcurrent and ref protection relay as per it-06 of ann-1. , 07sg4945037060-metrosil as per it-07 of ann-1. , 08sg4945037078-stabilising resistor 0-1k slash 0-5k as per it-08 of ann-1. , 09-sg4945037086-ethernet switch as per it-09 of ann-1. , 10-sg4945037426numerical main-1 line distance protection relay process bus as per it-10 of ann-1. , 11-sg4945037094numerical main-2 line distance protection relay process bus as per it-11 of ann-1. , 12-sg4945037108numerical main-1 line differential protection relay process bus as per it-12 of ann-1. , 13-sg4935117044numerical main-2 line differential protection relay process bus as per it-13 of ann-1 , 14-sg4945037124numerical main-1 line differential protection relay process bus remote end as per it-14 of ann-1. , 15sg4945037132-numerical main-2 line differential protection relay process bus remote end as per it15 of ann-1. , 16-sg4945037140-numerical transformer differential 3 wdg protection relay process bus as per it-16 of ann-1. , 17-sg4945037159numerical directional overcurrent and ref protection relay process bus as per it-17 of ann-1. , 18-sg4945037167-numerical frequency protection relay process bus as per it-18 of ann-1. , 19sg4945037175-numerical lbb protection relay process bus as per it-19 of ann-1. , 20-sg4945037183numerical teed protection relay process bus as per it- 20 of ann-1. , 21-sg4945037191-numerical busbar protection process bus as per it-21 of ann-1. , 22sg4945037205-bay control unit process bus as per it-22 of ann-1 , 23-sg4945037213-panel along with merging unit and switchgear control unit as per it 23 of ann-1. , 24-sg4945037221-ethernet switch as per it 24 of ann-1. , 25-sg4945037230-gateway slash networking panel as per it 25 of ann-1. , 26sg4945037248-ows ccr as per it-26 of ann-1. , 27sg4945037256-ews ccr as per it-27 of ann-1. , 28sg4945037264-laptop ccr as per it-28 of ann-1. , 29sg4945037272-a4 printer ccr as per it-29 of ann-1. , 30-sg4945037280-ows scr as per it-30 of ann-1. , 31sg4945037299-ews scr as per it-31 of ann-1. , 32sg4945037302-a3 printer scr as per it-32 of ann-1. , 33-sg4945037310-a4 printer scr as per it-33 of ann-1. , 34-sg4945037329-dot matrix printer scr as per it-34 of ann-1. , 35-sg4945037337-laptop scr as per it-35 of ann-1. , 36-sg4945037345-65 inches mimic display as per it-36 of ann-1. , 37-sg4945037353-inverter as per it-37 of ann-1. , 38-sg4945037361-network firewall as per it-38 of ann-1. , 39-sg4945037370-fo cable in mtrs as per it-39 of ann-1. , 40-sg4945037388control room furniture as per it-40 of ann-1. , 41sg4945037396-sas spares as per it-41 of ann-1. , 42 //bid details2 / 38sg4945037400-training as per it-42 of ann-1. , 43sg4945037418-ams as per it-43 of ann-1.
Tender For bid to ras providing of custom bid for services - configuration of networkequipments,custom bid for services - revamping of 48 port and 24 port of 30 nos 9u rack intranet and internet connectivity