Tender For providing of nucleic acid sequencing and genotyping service - dna sequencing; microbes / meta genome; nucleic acids (dna or rna); to be collected by the service provider from the buyer; illumina; 95% and above; 100x; high throughput; raw data; cloud storage; 30 d..
Tender For corrigendum : supply installation commissioning and maintenance of new switches for existing networkinginfrastructure and line array column speaker ups at high court complexes at jammu and srinagar
Tender For corrigendum : preparation of analytical reports based on dam storage data in pravah system for water resources management by using artificial intelligence (ai) tools
Tender For corrigendum : request for quotation (rfq) for selection of vendor from the empanelled list for supply, installation and commissioning of networkinginfrastructure (lan, wan and ups connectivity).
Tender For purchase of equipments - purchase of equipment: temperature compatible electrochemical device, the bidder is required to supply a handheld and wireless dual-channel potentiostat / impedance analyzer along with all necessary accessories and a compatible climate-controlled environment setup. the system must support sequential electrochemical measurements using both screen-printed electrodes (spes) and conventional electrodes. system specifications dc potential range: 2 v, maximum current range: 3 ma eis frequency range: up to ~200 khz, should support following techniques- linear sweep voltammetry (lsv), cyclic voltammetry (cv), square wave voltammetry (swv), differential pulse voltammetry (dpv), normal pulse voltammetry (npv), chronoamperometry (ca), pulsed amperometric detection (pad) open circuit potentiometry (ocp), multistep amperometry (ma) electrochemical impedance spectroscopy (eis) with scanning frequency mode and fixed frequency mode internal memory: onboard storage with capability to transfer data to pc via software interface usb or battery-powered operation wireless connectivity with tablet or pc (e.g., via bluetooth or wi-fi) environmental control requirementto maintain a consistent, controlled testing environment, a minimum 1.5 ton air conditioner (ac) unit must be supplied and installed along with the system. software & data handling software must allow real-time monitoring and data transfer from internal memory to pc user-friendly interface with exportable data in standard formatsdeliverables handheld dual-channel potentiostat / impedance analyzer, spe connector & cell cable, required software 1.5 ton air conditioner installation and commissioning user manual and documentation warranty & support minimum 1-year warranty on the entire system technical support and software updates during the warranty period
Tender For supply of frame , fc noxe , esc , bldc motor , bty , gps , propeller , receiver , analog camera , fpv goggles , radio transmitter , charger , fc with esc , camera sys , sd card for camera , sd card for fc for storage of flight data
Tender For supply of srphc154080-mri conditional pacing system with accessories for delivery of cardiac resynchronization therapy. system should include a current generation mri conditional crt pulse generator bipolar steroid-eluting atrial and ventricular leads and a quadripolar left ventricular ( coronary sinus ) lead and accessories ( lead introducers sheaths or guiding catheters etc.). should provide independently programmable right and left ventricular pulse outputsand interventricular delay ( with the choices of right ventricular alone left ventricular alone or biventricular pacing as well as the choice of which ventricle is to be paced first with optimization of delay for pacing of other ventricle ). should have features like negative av hysteresis and triggered modes for continuous delivery of crt. should have advanced features for detection and management and prevention of atrial tachycardias and atrial fibrillation as well as detailed data storage of all arrhythmias and therapy as well as trends over time. should have features for management of atrial fibrillation including mode switch ventricular rate management etc. pulse generator should be suitable for use with either an endocardial lv lead or an epimyocardial lead for lv stimulation. lv leads should have optimalfeatures for introduction positioning and fixation and documented low displacement rates. unit:no ]