Tender For corrigendum : armo e&m services at ddb, tower-c, mandi house, new delhi. (sh: supplying & replacement of 20hp & 18hp outdoor condenser unit in the circuit of mitsubishi heavy make vrf air conditioning system)
Tender For corrigendum : bore well submersible pump 5 hp submersible pumps 5hp submersible pumpset suitable for 4" borewell capable to delivery cold unfiltered water (head range 55-150 mts, discharge range 4000-10000 lph)complete with water lubricanted and suitable to operate on 415volts,50hz ac three phase supply conforming to is:8034/2002 or latestwith full automatic starter control panel along with, single phase preventer with phase reversal sensing and dry run relay protection ( current sensing type), voltmeter digital or analog (range of 0 to 500v), ammeter digital or analog ( range of 0ato40a), r,y,b indications lamps,on/off switch /push button and auto/manual mode switch. authorised dealer certificate to be submitted along with offer. test certificate, warranty certificate and user manualwith drawing circuit of the starter along with supply of material .pump make : ksb/kriloskar/deccan/texmo/cg/cri or similar ,starter make : c&s/l&t/siemens/abb/bch/powerpro or similar. [ warranty period: 30 months after the date of delivery ]
Tender For 25a, 2p, earth leakage circuit breaker operative at 230v, single phase ac supply and 30ma sensitivity and as per rcf specn. no. edts-118, rev -e, amend 2, corr 2 or latest for pantry unit of lhb type hot buffet eog coaches. [ warranty period: 30 months after the date of delivery ]
Tender For tender for supply of facility management contract of e and m installations of salem airport d d -monitoring and maintenance of utility services/internal and external electrical services at salem airport comprising of lt panels , dg sets , ccr panels , runway lighting , high masts , perimeter lighting , indoor and outdoor light fittings , power points , circuit/submain wiring , dbs , aviation obstruction lights , lightning arrestors , street light poles/external lights , signages etc. , (as per annexure-3 to 5 - list of inventories ) on duty basis by deputing sufficient number of manpower as per annexure-1 (8 hours of duty of time as decided by engineer-in-charge) , monitoring , control and general maintenance for 100% serviceability and i/c providing consumable material like cotton waste , oil , grease & other sundry material required for cleaning etc. , attending minor faults of equipments/ repairs/ replacement of defective components with aai supplied new components , ensuring 100% serviceability/ satisfactory working condition of the systems , routine and general preventive maintenance on daily/ weekly/ monthly/ quarterly/ half yearly/ yearly basis as per standard manufacturers practices and as per techno commercial specifications (tcs) , maintenance of records and log books (as per annexure-6 to 20) and reporting as and when required , complete upkeeping of the installations etc. , on all days as specified and as directed by engineer-in-charge as required. , maintenance of addressable type fire alarm system (fas) (by oem/authorized dealer of oem) including all associated and auto dialer of all fas types/models/make installed at following locations including programming , repairs and maintenance , attending faults of systems , replacement of defective components with aai supplied new components , ensuring 100% serviceability/satisfactory working condition of fas , routine and general preventive maintenance on monthly/quarterly/half yearly/yearly basis as per standard manufacturers practices , break-down maintenance , maintenance of records/service reports and reporting as and when required , complete up-keeping of the installations (fas) , as specified and as directed by engineer-in-charge as required. for first year (terminal building & technical block (make- edwards , model-io-1000)) , maintenance of addressable type fire alarm system (fas) (by oem/authorized dealer of oem) including all associated and auto dialer of all fas types/models/make installed at following locations including programming , repairs and maintenance , attending faults of systems , replacement of defective components with aai supplied new components , ensuring 100% serviceability/satisfactory working condition of fas , routine and general preventive maintenance on monthly/quarterly/half yearly/yearly basis as per standard manufacturers practices , break-down maintenance , maintenance of records/service reports and reporting as and when required , complete up-keeping of the installations (fas) , as specified and as directed by engineer-in-charge as required. for first year (ndb room (make- edwards , model-io-64)) , maintenance of addressable type fire alarm system (fas) (by oem/authorized dealer of oem) including all associated and auto dialer of all fas types/models/make installed at following locations including programming , repairs and maintenance , attending faults of systems , replacement of defective components with aai supplied new components , ensuring 100% serviceability/satisfactory working condition of fas , routine and general preventive maintenance on monthly/quarterly/half yearly/yearly basis as per standard manufacturers practices , break-down maintenance , maintenance of records/service reports and reporting as and when required , complete up-keeping of the installations (fas) , as specified and as directed by engineer-in-charge as required. for second year (terminal building & technical block (make- edwards , model-io-100
Tender For corrigendum : supply of spares field switch of be1800e shovel c c > f> f - shunt trip coil assly 110v dc part no fsb0001 , electric closing coil assly 110v part no fsb0002 , h t c t class 1 point 0 5p 10 part nofsb0040 , core balance transformer lt part nofsb0046 , auxiliary contactor part nofsb0049 , pilot relay 110v dc part no fsb0051 , push button part no fsb0054 , limit switch part no fsb0057 , earth leakage relay 110v wire door mountd part no fsb0062 , complete vcb assembly part no fsb0063 , 6 6kv 3 3kv 110v 3ph 2 point 5kva transformer part no fsb0066 , lt fuse for control circuit part no fsb0083 , hrc fuse for pt ht side part no fsb0084 , hrc fuse for pt lt side part no fsb0085 , timer part no fsb0087 , limit switch part no fsb0088 , over voltage relay part no fsb0107 , under voltage relay part no fsb0108 , push to trip knob part no fsb0109 , ground check relay part no fsb0112 , time delay relay part no fsb0113 , anti pumping contactor part no fsb0115
Tender For to supply circuit breaker analyzer test kit and accessories - 3 channel dcrm (200a), transducer, laptop and trolley at bhira avajal power station rawalje.