Web Analytics Made Easy - StatCounter

Ngo Tenders

Get complete information related to latest Ngo Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Ngo Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Ngo Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

State Government

CTN :38580650 Due date: 23 Dec, 202423 Dec, 2024 7.87 Lacs
Tender For construction of 2 nos room and toilet at ngo club 26bn saf guna

CTN :38581751 Due date: 19 Dec, 202419 Dec, 2024 1.57 Crore
Tender For selection of registered institution/ngo/registered trust/registered cooperative institutions, etc. for establishment and construction of panchayat samiti level nandishala (9 in barmer district and 7 in balotra district, one in each panchayat samiti)

State Government

CTN :38556832 Due date: 21 Dec, 202421 Dec, 2024 2.54 Lacs
Tender For general-pwd- quarters at jawahar nagar and haihar nagar-routine maintenance work for the period second half of fy 2024-25- go and ngo quarters-buildings section vellayambalam-general civil work

State Government

CTN :38530201 Due date: 19 Dec, 202419 Dec, 2024 3.85 Lacs
Tender For appointment of ngo - awareness programme for tobbaco in schools with iec material.

State Government

CTN :38539804 Due date: 23 Dec, 202423 Dec, 2024 NA
Tender For ei works of proposed g plus 3 model for single 100 bedded pre - fabricated covid ward-design, supply, installation, testing and commissioning of hvac system with negative room pressure system for the 22 beded icu of single 100 beded covid ward at gazol rh-additional work

CTN :38526865 Due date: 18 Dec, 202418 Dec, 2024 27.60 Lacs
Tender For short term request for proposal for providing yoga training to patients of namma clinics of bbmp on outsourced basis by interested firm/ngo/organisation

Central Government/Public Sector

CTN :38157116 Due date: 27 Dec, 202427 Dec, 2024 1.30 Crore
Tender For corrigendum : special repair for renewel of e/m items and plant/ machinery held in charge of age (e/m) rnd agra cantt under ge (i) rnd delhi - supply , installatation , testing and commissioning of diesel driven generating set to give an out put of 500 kva, 415v ac supply 3 phase, 50 hz, 4 wire radiator mounted on common base plate complete with fuel tank, vibration damper and other accessories with fuel tank viberation damper and other accessories with acoustic enclouser as per latest cpcb-iv norms and amf panel including pcc foundation work as per oem reccommandation and taking out the old dg set from the location and deposited to mes store yard complete all as specified and directed, interanally comprising of following :-(a) diesel driven engine :- developing a net output suitable matched to give a net rated output of minimum 604 hp/suitable to drive 500 kva alternator, at 0.8 power factor 415 volts. the engine should be capable of delivering the required output at 1500 rpm, water cooled, self start, with a provision of 10% overload for one hour in every 12 hours with the following accessories and all as specified.(i) fly wheel to suit flexible coupling and fly wheel housing.(ii) air cleaner complete as per manufacturer specification. (iii) fuel injection pump. (iv) flexible coupling with guard, nuts and bolts.(v) fuel filter with mounting. (vi) oil filter with mounting.(vii) starter motor as per manufactures design.(viii) exhaust, silencer industrial type with exhaust pipe suitable length.(ix) batteries 12 volts 2x180 ah maintenance free batteries with copper lead, terminals etc.(x) instrument panel complete with microprocessor based controller comprising shut down valve indication, lcd hour counter indication, rpm indication , led lamps for fail to start, over speed /under speed . low lub oil pressure, high engine coolant temperature. gaugae.(xi) dynamo/alternator suitable rating., (b) alternator :-the above engine will be coupled through flexible coupling on an indigenous alternator mounted on a strong steel fabricated common base frame suitable for mounting in an acoustic enclousre. the alternator will be 3 phase 50 hz 1500 rpm self regulating self exciting type and have class h insulation of stator and rotor windings and generate 500 kva output at .8 power factor 4 wire 415 volts ac supply under ntp condition with a provision of 10% overload for 1 hour in every 12 hrs running. the alternator would be screen protected and fitted with shield ball/roller bearing, automatic voltage regulator.(c) control panel :- s&f amf (automatic on mains failure) control panel cpri approved outdoor ype kiosk water, dust and vermin proof and fabricated out of 3.15 mm thick crca sheet and 50mm x 50mm x 6mm angle iron powder coated suitable for 415 volts 3 phase 50 hz ac supply with and incl the following :-(i) mccb of suitable capacity(ii) necessary relays, times and power contractors of suitable rating/capacity for auto on-off the dg set and changeover of the load in case of power failure.(iii) digital mulfifunctional meter for phase wise reading of amps, voltage kwh and frequency -01(iv) internal wriring with single core solid copper conductor cable of appropriae gauge incl mumbering ferrules and control fuses.(v) earthing terminals 02 nos(vi) auto/manual start switch to by pass auto start.(vii) battery charging system suitable for charging for charging the battery provided with the dg set incl boost/stickle switch and system, dc voltmeter digital type., (d) fuel tank :- one no built in sheet metal steel tank mounted inside the acoustic encloser and of adequate capacitynot less than 740 ltr with inlet and outlet connection including the following :-(i) level indicator with float and gauge.(ii) fuel piping for fuel supply to engine and over flow to tank(iii) fuel strainer(e) acoustic enclosure :- enclousre be designed for reducing the sound level up to 75+/ 5db (average) as per is 8528 part 10 and as per approved cpcb morms. the acous

corporations/Associations/Others

CTN :38506394 Due date: 18 Dec, 202418 Dec, 2024 1.89 Crore
Tender For construction of science park at ngo colony park perungalathur ward no 58 survey no 365/a2 in tambaram city municipal corporation

State Government

CTN :37664022 Due date: 23 Dec, 202423 Dec, 2024 5.15 Lacs
Tender For corrigendum : supply of various types of consumable and routine mainteneance items for c&i system at gbps,utran - air filter cum regulator input 0-14 kg/cm2, secondary (output) pressure 0-7 kg/cm2 filter 5 micron, size 1/4"npt (f), air filter regulator size: 1/2", polyurethane material flexible tube type: pu-6 or equivalent ,festo make, festo make polyurethane material flexible tube type: pu-8-sw, high speed portable blower,550 w (min.),cap-3.8 m3/minute,16000 rpm,1.7 kg., hand drill machine size 13mm, digital infrared thermometer (type: portable non-contact type thermometer, range: -40 to 800 deg.centigrade, sighting: laser guided, accuracy: +/- 0.5 deg. centigrade), hammer drill with drill spanner, 3 way gauge cock, matl: ss-316, process conn: 1/2 inch nptf to suit 1/2 inch od ss tube, ss 316 union fitting 3/8 x 3/8 bsp (m), ss adoptor fitting 1/2"bsp(f)x1/2"npt (m), ss fitting swage lock type to suit 1/2"nb pipe x to suit 1/2" od pipe, ss 1/4" od (std) double ferrule compression fitting, ss 3/8" od double ferrule compression fitting, ss tube fitting ss 316 1/2"npt m x to suit 1/2"od ss tube with nut and ferrule, ss 316 union fitting 1/2"x1/2"od, equal tee matl: ss316 to suit 1/2"od ss tube, ss 1/2" od double ferrule compression fitting, double ferrule compression for ss 1/4" od (std) each set contain 100 nos ferrule, double ferrule compression for ss 1/2 " od (std) each set contain 100 nos ferrule, double ferrule compression for ss 3/8 " od (std) each set contain 100 nos ferrule, networking cable cat 6, for computer lan connection., dcs work station panel cooling fan, cable tie 100 mm, cable tie 150 mm, cable tie 200 mm, 1/2" nb, ss-316l, sch-40, seamless stainless steel pipe., puf seal self expanding foam for sealing, limit switch,make: honeywell, type: szl-vl-i, 10a, 250v ac,1n0-1nc,ip-67., hss drill bit set 3 mm to 12 mm, industrial vacuum cleaner.motor specification: watts capacity: 1200 w max., voltage: 220 - 240 volts a/c supply, capacity: 15 ltr, all standard accessories., soft faced hammer with handle, generally conforming to is 10838-1984, mallet size - 20mm, hand lamp holder with 15 mtr wire and protection glass, 20 amp. 240v spn industrial type socket outlet with 2 pole and earth metal enclosed plug top along with 20 amp. c series sp mcb in sheet steel enclosure on surface with chained metal cover for the socket out let., two valve manifold, ss 316,with vent plug 1/2 inch nptf, pressur rating 3000 psi, needle valve, matl: ss-316, process conn: 1/2 inch od ss tube, three way valve rating: 800lbs size: 2x3/4" nb-swx1/2" nptf body:astma105, three valve manifold with vent plug port size:1/2" nptf matl:ss316 pr.testing:3000psi, five valve manifold, ss 316, with vent plug 1/2 inch nptf, pressure rating 3000 psi., ss quarter fitting union, ss adoptor fitting 1/2"bsp(f)x3/8"bsp (m), ss fitting swage lock type 1/4"npt m x to suit 3/8" od pipe, ss fitting swage lock type 3/8"npt m x to suit 3/8" od pipe, ss bulk head union 1/2 nb sw x i/4od, ss bulk head union 1/4 od sw x i/2 nb sw, limit switch, make siemens,model no. 3se5122 - 0ya00,contacts : 1 no + 1 nc., ss 1/8 npt (m) union with nut and ferrule, teflon tape : size 1/2" width x 12mtr long, hss hacksaw blade size 300x12.5x0.63 mm, fevi kwik tube 3 grams

CTN :38458596 Due date: 19 Dec, 202419 Dec, 2024 13.49 Lacs
Tender For replacement of existing damaged ugd sewer pipeline from d.no. 6-8-1176 to 6-8-1144 at ngo colony ward no. 40 under zone-v municipal corporation, tirupati (reserved for sc/st and waddera).
 Loading, Please wait...

Connect us via What's Up