Get complete information related to latest Niwar Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Niwar Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Niwar Tenders.
Tender For manufacture and supply of mono block pre-stressed concrete line sleeper (pre-tensioned type) confirming to rdso drg. no. t-8746, alt-1 (6 th revision march 2021 with corrigendum no. 1, with latest alteration as on date of tender opening) and irs specification no. t-39-2021 (as amended up to d ate of tender opening) duly loaded into wagons/road vehicles. [ warranty period: 60 months after the date of delivery ]
Tender For manufacture and supply of mono block pre-stressed concrete line sleeper (pre-tensioned type) confirming to rdso drg. no. rt-8746 and irs specification no. t-39 (drawing and specification as amended upto date of tender publishing) ]
Tender For manufacture and supply of mono block pre-stressed concrete line sleeper (pre-tension ed type) confirming to rdso drg. no. t-8746 and irs specification no. t 39 )duly loaded into wagons/r oad vehicles). [ warranty period: 60 months after the date of delivery ]
Tender For supply of h2 8305 000243 malmal cotton white bleached 112 cm wide , h2 4020 000077 rope coir hawserlaid 3 strand 8 mm dia , h2 4020 000136 rope cott h laid rot proofed undyed 8mm , h2 4020 000138 rope hawserlaid rot proofed undyed 38 mm , h2 4020 000149 rope jute hawserlaid 8 mm dia , h2 4020 000039 rope manila h l 3 strand gde iii 32mm , h2 4020 000022 rope sisal h l 3 strand r p unwrap 8mm , h2 4020 000026 rope sisal h l 3 strnd r p unwrpd 20 mm , k6 7330 000053 utensil cooking 4 men set degchie medium , k6 7330 000059 utensil cooking 4 men set part large , k6 7330 000064 utensils cooking 45 men set chamcha , k6 7330 000069 utensils cooking 45 men set pona , k6 7330 000052 utnsils cooki 4 men set degchi large lid , k6 7310 000015 wire gauge stove oil w l no 100 , h2 8315 000311 tape niwar og 40 mm , h2 8315 000318 tape niwar undyed 40 mm , h2 8310 000074 thread cotton ind 500 dtex x 4 unbleached , h 2 4720 000408 casd tubing rubber interial diameter 6.3mm , h2 4020 000181 twine europe , h2 4020 000195 1 twine jute 3 ply , h2 8305 000266 web thick og 32 mm + /bid number : gem/2025/b/6297953 , /dated: 08-06-2025 ( ( / bid document 1 / 23
Tender For supply of 2 channel and 02 output channels public address pa amplifier lxa 3200 out put 1501 to 1750 watt number of output channels line 2 treble 10 db at 10 khz bass 10 db at 100hz , analog 24 volt pa mixer special mixer 912dp number of channel 09 ac operated input mic line mono stereo output sterio built in usb option treble 20000hz bass 20 hz model amx912dp , wall speaker model wsx 68it frequency response 150 10000 hz wall mounting one way configuration power rating 8 watt dimensions h xw xd w 230 x h 250 x d115 , wall speaker 25 watt model ws 6255t frequency response 150 to 10000 hz wall mounting one way configuration power rating 25 watt dimensions h x w x d w 262 xh 262 x d 128 , pa horn model suh 40 xt horn diameter 200 mm body of horn plastic operating voltahe 100 volt rated power 40 watt frequency 300hz to 7 khz ip rating 65 power o p adjustment yes , two way pa speaker model no srx 500 ,frequency range 20 to 20000 hz two way configuration speakerported normal impedence ohm 8 ohm maximum sound pressure db 101 db out put 400 watt , wireless cardioid microphone model awm 495 vhl operating range 100 mtr frequency response 20 to 20000 hz audio connector type xlr volume control , hand held wired cardioid microphone model adm 411 microphone transducer type dynamic freqn response 20 hz to 20000 hz casing material metal , wired cardioid microphone gm 601lmwith gmb6c microphone type dynamic sensitivity 315 mv hand held wired cardioid microphone model adm 411 casing material metal , 2 core flexible wire number of core 2 core type of product fr flexibel cable cable length 100 mtr sq mm one point five mm conductor material copper , flexible cable number area in sq zero point seventy five mm no of cores single core conductor materials copper , pvc conduit pipe material pvc resin nominal size of the conduit 32 mm length 3 mtr , networking flexible pipe material ppr outer surface pattern zig zag shape round length -1800 mm five point ninety ft , cider circle cable clip clip material pvc nail size 32 mm quantity per packet 100 numbers , installation of 8 watt speaker 30 number, 25 watt speaker 16 number and horn 4 number in various places of campus area
Tender For instruments for shrawani mela year 2025-26, hospital and other health centre. - stainless steel abdominal hysterectomy set, n.s.v set (s.s), g.v set, self abdominal detractor, m.t.p set., vaccine carrier (small size), x-ray digitalisation with high-end cr system (with installation & 1 yers. warrenty) console software with mulitmodality work station the cr system should have advances workstation provided with 17" high resolution monitor, keyboard & ouse, with the fol., digital ultrasound machine colour dopler (high resolution ) with 4 probe, semi auto analyzer, fully automated bio-chemistry analyzertechnical specificationsthroughput-150t/hr (constant with both mono and double reagent)system function-random access/stat/batchtest method-end point, fix time, kinetic, (single/double reagents chemistry, mono/ bio-chromatic measurements)calculation methods-1 point linear, 2 point linear, exponential, logit log3p, logit log 4 p, logit log 5p, spline, line graph, k factorblank-reagent blank, sample blank, pre sample blank, pre reagent blanksample tray-40 position, sample volume :2-30 ui, 0.1 ul increment, micro cup, & test tube can be used for samplereagent tray-80 position, reagent volume: 20-300 ul, 1 ul incrementmixing system-teflon coated mixersample probe-1 needle with liquid detector, shock sensoroptics-halogen-tungsten lamp, absorbance range: 0-4.0 abs resolution: 0.0001 abs.diffraction photometry with wave length: 340, 405, 450, 505, 546, 578, 630, 700nm & 4 more optionswash station-12 step washing, 4 needle wash station, 1 dry pad, external needle cleaningcalibration-linear and non-linearqc-multi-level qc setup with levy-jennings graph and westgrads multi rules with mean sd, and cvwater consumption-not more than 6l/hrtemperature-reagent: 2-14 c (24 hr refrigeration), reaction cuvette: 37c 0.1 humidity- 80%system interface-usbpower requirement-ac 220v 10%, 50/60 hzdimensions-750 mm*560mm*530mm, hotair oven, binocular microscope (olampus), centri fuge machin (good quality), micropipette (0-50 microliter), micropipette (0-500 microliter), micropipette (0-1000 microliter), microtips (0-50 microliter), microtips (0-1000 microliter), bed side screen with cloth 1"round pipe with wheel, sponge holding (all size), artery forceps 6" curved, artery forceps 6" straight., artery forceps 8" curved, artery forceps 8" straight., artery forceps 4" straight., alliys tissue forcep (all size curved straight), mosquito forcep (all size curved straight), scissor 6 " curved (all size), scissor 6 " straight (all size), scissor mosquito straight. (all size curved, straight), diatheromy (machine), laparoscopic instrument full set (best quality), needle holder 8 "curved, needle holder 8 " straight, needle holder 6 "curved, needle holder 6 " straight, needle holder 4 "curved, needle holder 4 " straight, doner couch (3 motor), blood weighting mechine, blood band refrigerator (300 bag) temp.display outside, elisa reader with washer mechine with printer & ups., fully automated chemiluminescence analyzer(clia) 1. system should be fully automated walk -away with continuous loading facility.2. analyzer should have able to perform thyroid, bone, cardiac, fertility, diabetes and anemia profile test.3. working principle of system should be micron super paramagnetic particles platform with alp labeled reagents and amppd substrate.4. must have 3 phase magnetic separation with precisely controlled temperature.5. analyzer should have photon counting detection mode with photomultiplier photo counter with led reference module.6. the analyzer must have vortex non-touch mixing which can reduce carryover., 7. throughput of the system should be more than 180 tests in a hour.8. system should have 15 reagents onboard with onboard 2 -8 nonstop refrigeration facility 9. system should have at least 50 sample positions and continuous loading facility.10. system should have continuous reagents loading, real time mixing for magnetic particles.11. sample probe a
Tender For supply of h1 5350-000024 abrasive paper emery or corundum is grit , h1 5350-000023 abrasive paper emery or corundum is grit , h1 5350-000028 abrasive paper emery or corundum is grit , h1 5350-000026 abrasive paper emery or corundum is grit , h1 8040-000042 quick fix , h1 8010-000290 oil linseed raw , h1 8030-000032 mineral jelly (ammunation) , h1 6810-000040 spirit denatured , h2 8305-000230 felt w/rot & m/proofed 13mm tk 132cm v-5 , h2 4020-000556 rope p/lene 3 strand h/l og 24mm dia , h2 4020-000557 rope p/lene 3 strand h/l og 32mm dia , h2 8305-000083 long cloth white bleached 91 cm wide , h2 8305-000267 web thick og 38 mm , h2 8315-019777 tape niwar undyed 25 mm