Tender For supply of supply of intelligent multi-criteria photo electric smoke & thermal detector, white colour, suitable , supply of 2-zone gas release fire alarm panel designed for gas suppression systems. it features a 16 , supply of addressable dual- action manual pull station-red in colour, designed for fire alarm systems , supply of sounder with 90 db output at 1 metre distance cum strobe lights with 110 cd as per specifi , supply of dual-action manual abort station - yellow in colour, designed for fire alarm systems. cons , supply of dual-action manual release station -green in colour, designed for fire alarm systems. cons , supply of addressable relay output module with programmable dry contact output for interfacing with , supply of addressable supervised control module for operating sounders/ horns with line monitoring, , supply of addressable monitor module for supervision of potential free contacts such as flow switche , supply of 2c x 1.5 sq. mm fire survival un- armoured cables (300/500 v) with copper conductor, cross- , supply of electric gas release caution sign boards (24 v dc) for approved locations. make: std , system rectification, modification, re-programming & cleaning charges
Tender For providing and fixing clean agent gas based cylinder less fire suppression system in existing main switches installed on rising main and electrical panels in different locations at iit delhi.
Tender For supply, installation, testing and commissioning of tubing based automatic fire detection and clean agent gas based fire suppression system at d.b. rooms (2 nos.) at each floor of core-3 and 4 at scope minar, laxmi nagar, delhi-110092.
Tender For supply of halocarbon agent based fire fighting system c c - pipe line for gas nozzle fitment 35 mm including fitment , 34 ltrs automatic in direct low pressure valve with solenoid fire suppression cylinder , fire finder polymer tube for automatic fire detection and suppression system made by special modified , fet end of line adapter with pressuure gauge for automatic fire suppression tube used for fitting at end of tube for pressurising and re pressurising the tube , fet pressure switch to monitor presure drop in the tube , master control unit for connecting each system with electronic hooters and productivity input to scada , all necessary fittings cabling and clamp to complete the system , installation adn commissioning charges including complete setup of the system installation of cylinders on specially designed brackets