Tender For supply of 1603apctrcb030vd part no anti pumping relay 30v dc , 1103ct301a5p1 part no heavy duty oilcooled current trnsfrmr , 0802bcol025xx part no tripping coil assembly 30v dc , 1503lr4x03x21x01 part no trip circuit supervision relay , 1103pt11kv2119 part no potential transformer , 1603aerymxxr10 part no numerical idmt relay with 3 oc and 1 ef , 2102daua3vc10306 part no digital amper meter , 1503lr4x12x14xxx part no auxiliary relay with double sensing unit , 0202vcbcire08 part no spring charge motor , 2100trmbkcstce95 part no master trip relay w singel sensing unit , 1503bcagr145xx144 part no battery and charger , 0805viag53xx02 part no vaccume interrupter assembly complete , 0605bba22cx133 part no control cabel connection complete set , 2102mcbacdp10a21 part no mcb double pole 10a ac , 0804bcol05c01 part no closing coil assembly 30v dc , 2102cil22uv0ub20 part no indicating lamp 24 240v ac dc blue , 2102cil22uv0ug20 part no indicating lamp 24 240v ac dc green , 2102cil22uv0ur20 part no indicating lamp 24 240v ac dc red , 2102pbfhdrdx0301 part no push button red , 2102dmfmxxxx18xx part no digtal multifunctional meter , 0805gaca64xxx02 part no gear assy closing assy w charge locking ) /bid number: gem/2026/b/7258762 * /dated: 18-02-2026 & & / bid document1 / 30
Tender For supply of single phase two wire, direct current operate dual source prepayment (auto dg sensing) energy meter having calibration led & load controlling feature & provision of tod (time of day) tariff and r.t.c (real time clock) with bluetooth in-home -display, 230/240 v ac,50 hz +/- 5%, current: 5 to 60 amps, wall mounted projected type, accuracy class: 1.0, ingress protection : ip54, up to 8 tariff rates ( slab or time-of-use), enclosure:unbreakable high-grade fire resistant, reinforced polycarbonate or equivalent high- grade engineering plastic,sealing provision; sealed for life, additional sealing provision at meter cover and terminal cover, standards: is 13779,is 15884, is 15959 and iec 62055-31, shall have capacitive, phone-style touch pad with multiple parameter navigation, touch type keypad functionality,meter shall have completely insulated body and be of wall mounted projected type, lcd display with minimum 8 digit, easy token transfer over bluetooth, enables data collection over ble, authenticated billing code(abc) with time stamp, with a parallel bluetooth enabled freedom unit for token transfer and abc reading through mobile app, os/android/windows with 3 years annual vending charges. as per pcee/ecor/bbs spec.no. ecor/el/pcee/spec/prepaid-energy meter/2019 (rev-1)-2020. make: secure or hpl or l&t or similar.
Tender For corrigendum : technical specification point wise dbs implant & accessories - dbs rechargeable with directional lead with25yr battery life & image guided programming integrated inside clinician programmer with micc multiple independent current control technology with zero volt technology,bluetooth connectivity with clinician and patient programmers, usfda & ce approved kit contents: rechargeable pulse generator-1 , directional lead kit -2 , extension kit -2 , burr hole locking kit -2 , tunneling tool -1 , patient remote control kit -1, patient charging kit -1 , dbs rechargeable with non directional lead with 25yr battery life & image guided programming integrated inside clinician programmer micc multiple independent current control technology with zero volt technology,bluetooth connectivity with clinician and patient programmers. have 8 contact non-directional lead kit with array span of 15.5mm for maximum coverage, usfda & ce approved kit contents:rechargeable pulse generator -1, non-directional lead kit -2, extension kit -2, burr hole locking kit -2, tunneling tool -1, patient remote control kit -1, patient charging kit -1, dbs non rechargeable with directional lead with image guided programming integrated inside clinician programmer micc multiple independent current control technology &bluetooth connectivity with clinician and patient programmers,usfda & ce approved kit contents: non-rechargeable pulse generator -1 , directional lead kit -2 , extension kit -2, burr hole locking kit -2 , tunneling tool -1 , patient remote control kit -1,), dbs non rechargeable with non-directional lead with image guided programming integrated inside clinician programmermicc multiple independent current control technology withbluetooth connectivity with clinician and patient programmers. should have 8 contact non-directional lead kit with array span of 15.5mm for maximum coverage,usfda & ce approved kit contents: non-rechargeable pulse generator -1, non-directional lead 1), dbs implant kit with non-rechargeable, 3t mri compatible and sensing enabled ipg and directional leads.the implanted pulse generator (dbs neurostimulator- ipg) should have a minimum service life of 5-7 years and there should not be a need to recharge it periodically.ipg should have the capability for group programming and ability to store the programming data in ipg itself and retrieve from ipg.the system should be able to sense local field potentials (lfps) from brain targets and this data should be accessible through the physician programmer. the leads should be able to stimulate in specific directions, in addition to the ability to stimulate circumferentially. markers on leads should facilitate directional programming even if lead rotates. the leads should also be able to sense lfps.burrhole kit should be there for securing lead in place. microelectrodes for intra op stimulation and recording should be there.the extension connecting the lead and ipg should be flexiblethere should be a tunneller to place the extension wire and the tunneller should be metallic and firm to enable smooth tunnelling.the system should have approval for conditional full-body 1.5t & 3t mri compatibility.patient programmer, enabling the patient to see and if needed, modify the stimulation under guidance, should be available. patients should be able to mark dyskinesia, tremor etc. using the programmer., dbs implant kit with rechargeable, 1.5t & 3t mri compatible and sensing enabled ipg and directional leads.the implantable pulse generator (dbs neurostimulator- ipg) should have a service life of 15+ years if regularly recharged by the patient at specified intervals.ipg should have the capability for group programming and ability to store the programming data in ipg itself and retrieve from ipg.the system should be able to sense local field potentials (lfps) from brain targets and this data should be accessible through the physician programmer. the system shou