Tender For supply of genr set 30 kva engine overhualing and repair of panel board and other issues , genr set 30 kva replace of mounting chassis and armature fixing , genr set 35 kva engine overhualing and repair of panel board and other issues , genr set 3 kva engine overhualing and other issues , genr spares i e fuel filter oil filter air filter fan belt exhaust fan mounting pad etc , canopy repair , armature rewinding , armature cooling fan , bty 12 v 130 ah , bty 12 v 90 ah , bty 12 v 65 ah , bty 12 v 9 ah , avr green , self starter solenoid , armature for self starter , alternater for bty charge , fuel feed pump , carburetor , wall mixer hot and cold single lever make jaguar , piller cock 15 mm hot and clod single lever make jaguar , angle cock 15 mm make jaguar , water pump 0 point 5 hp online make crompton , bath mat of size of 10 x 5 long , concealed ceiling round led light 18 w 9 x 9 , washbasin waste pipe , urinal wast pipe , door handle as per sample , mortice lock 4 lever with handle , exhaust fan of size 6 inch , electric gyser cap 3 ltrs , vitourios china wash hand basin with complete accessories , jet spray for toilet seat , looking mirror , waterproof fire retardant tarpaulin of minimum size 30 x 30 isi marked , celing led light 200 x 200m 18w , acp panel as per sample , hydraulic oil , plywood 8 x 4 x 19mm , godrej interio plastic pulse aero mesh back office chair with adjustable arm rests synchro mechanism black , fevicol sr , nails 1 or 2 1 1 point 5 2 , paint brown green white chocolate golden cream and black , synthetic camonet desert pattern size of 11m x 16m , repairing and service of ac , 1 square pipe 20 long , 1 point 25 square pipe 20 long , cement , sand , aggregate 20mm , brick , tiles 2x4 , tiles 2x2 , steel bar , water profing , white cement , wall tiles area 360 1x1 bid number/ ( ( ) ): gem/2024/b/5677467 dated/* : 10-12-2024 bid document/ 1 1 / 42
Tender For repair to hero honda ba no 10a 061722x - labour charge for repair replacement , spark plug , electric starter , drive chain , drive chain slider , brake shoe , kick starter paddle , side view mirror , fairing front , feeder feet , side stand , clutch wire , speedometer kit , horn switch , head light bulb , tail light set , mud guard front , fork left front , material and labour for removing and refixing , material and labour for removing and refixing , abour charge for complete servicing washing and replacement of oil and filters , engine oil , air filter , clutch oil comma break oil comma coolant , oil filter , labour charge for repair replacement of wiring harness rat bitten of complete vehicle , material and labor for seat cover complete
Tender For supply of repair of engagement light-installation and shifting of engagement light , repair of engagement light-connection switch , repair of engagement light-change of copper wire , repair of engagement light-supply and fixing of zero watt bulb , repair of engagement light-supply and fixing of gang box with switch , repair of call bell-change of copper wire 3/2 core , repair of call bell-connection switches etc , repair of call bell-supply and fixing of push switch , repair of call bell-installation and shifting of call bell , repair of call bell-supply and fixing of gang box with switches , repair of electric kettle-change of wire , repair of electric kettle- change of adaptor and socket , repair of electric kettle- change of heating element , repair of electric kettle- change of handle , repair of food warmer-supply and fixing of plug , repair of food warmer-supply and fixing of element , repair of food warmer-supply and fixing of indicator , repair of food warmer-supply and fixing of glass , repair of food warmer-supply and fixing of wire , repair of food warmer-supply and fixing of temperature knob , repair of food warmer-supply and fixing of thermostat , repair of extn board-change of fuse , repair of extn board-supply and fixing of switch (anchor) 5/15 amp , repair of extn board-supply and fixing of indicator anchor lamp , repair of extn board-only repair including connection and the box , repair of extn board-change of wire , repair of extn board-supply and fixing of 5amp anchor socket , repair of extn board-change of plug , repair of extn board-supply and fixing of 15amp anchor socket , repair of room heater-supply and fixing of filament rod , repair of room heater-supply and fixing of reflector , repair of room heater-supply and fixing of grill , repair of room heater-change of wire , repair of room heater-change of plug , repair of room heater-change of sleeves , repair of heat convector- fitment of plug , repair of heat convector- fitment of fan blower , repair of heat convector- change of motor , repair of heat convector- change of switch , repair of heat convector- change of thermostat , repair of heat convector- change of element , repair of heat convector- change of chord , repair of heat convector- change of indicator , repair of heat convector- change of handle , repair of otg , repair of induction cooktop , repair of microwave oven , repair of oil heater , repair of engagement light change of gloves/glass cover full , repair of electric kettle-change of plug
Tender For corrigendum : repair and maintenance and replacement of street light, flood light, timer panel, high mast light, electric poles and other related work in archarya enclave, yashwant vihar, harshan enclave i and ii, virk enclave and mes ib under ge belgaum
Tender For repair and replacement of electric wiring, light fittings and connected e/m items at hq delhi area, stn hq, did line, dapu, harbux statium, printing press complex, 10 pars, echs, huts and connected areas under ge (east) delhi cantt-10
Tender For supply of labour charge for complete servicing comma washing and replacement of oil and filters , engine oil , air filter , labour charge for repair replacement of wiring harness of complete vehicle , labour and material for printing of all mes and command logo with ba no of vehicle , labour for repair replacement of following parts , front shock absorber , head light bulb , clutch wire , speedometer wire , clutch plate , brake shoes , indicator assembly , spark plug , electric starter , sheet cover
Tender For comprehensive maint contract annual maintenance contract of prepaid electric meters at ranikhet maint repairs of solar water heating system solar security light dg sets repair maint of refrigeration and air conditioning applaiances at ranikhet and chaubattia under ge ranikh
Tender For repair/ replacement of lt underground cables and connected items in various locations at mil stn yol - excavation in trenches, not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10 sqm on plan and not exceeding 1.5 mtr in depth and getting out in hard dense soil, complete all as specified and directed., excavation in trenches, not exceeding 1.5 mtr wide and exceeding 1.5 mtr but not exceeding 3 metre in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10 sqm on plan and not exceeding 1.5 mtr in depth and getting out in hard dense soil, complete all as specified and directed., returning filling in (soil) including spreading, levelling, watering and well ramming in layers n.exc 25cms thick in any type of soil complete all as specified and directed., removing excavated materials/ soils, not exceeding 50mtrs and depositing where directed at a level not exceeding 1.50mtrs, complete all as specified and directed., pcc 1:3:6 (nominal mix) type c-2 (using 40mm graded crushed stone aggregates) as in coping of pole including necessary form work complete all as specified and directed., pcc 1:4:8 (nominal mix) type d-2 (using 40mm graded crushed stone aggregates) as in foundation filling and mass concrete complete all as specified and directed., sand cushioning to protection of underground cables, laid 8 cm before laying and 15 cm after laying of cable, and punned to form an overall layer of 18 cms thick, complete all as specified and directed note: punned thickness shall be measured., sub class b brick, old size, brick covering laid dry, flat, transversally along the length of cable on sand cushioning, with width equal to the length of the brick including taking out old bricks, complete all as specified and directed., laying only bricks along the length of cable on sand cushioning, with width equal to the length of the brick , complete all as specified and directed., mild steel galvanised iron tubing light grade for cable protection as in road crossing, along poles, walls, floors, drain of 80mm size fixed with ms clamps, nuts and bolts required complete all as specified and directed., mild steel galvanised iron tubing light grade for cable protection as in road crossing, along poles, walls, floors, drain of 50mm size fixed with ms clamps, nuts and bolts required complete all as specified and directed., dismantling poles/struts, any size and type including insulators and removing from site, complete all as specified., supply, jointing, fixing or passing through pipe , trenches or ducts, commissioning and testing xlpe insulated screened and pvc sheathed armoured electric power lt cable heavy duty with aluminium conductor nominal cross sectional area 300 sqmm 3.5 core for working voltage upto including 1100 volts conforming to is-7098 (part-i) 1988 including taking out existing unserviceable cable, complete all as specified and as directed., supply, jointing, fixing or passing through pipe , trenches or ducts, commissioning and testing xlpe insulated screened and pvc sheathed armoured electric power lt cable heavy duty with aluminium conductor nominal cross sectional area 240 sqmm 3.5 core for working voltage upto including 1100 volts conforming to is-7098 (part-i) 1988 including taking out existing unserviceable cable, complete all as specified and as directed., supply, jointing, fixing or passing through pipe , trenches or ducts, commissioning and testing xlpe insulated screened and pvc sheathed armoured electric power lt cable heavy duty with aluminium conductor nominal cross sectional area 185 sqmm 3.5 core for working voltage upto including 1100 volts conforming to is-7098 (part-i) 1988 including taking out existing unserviceable cable, complete all as specified and as directed., supply, jointing, fixing or passing through pipe , trenches or ducts, commissioning and testing xlpe i
Tender For repair/replacement of lt ug cable, lt poles, control panels board, change over switches and allied items at af station naliya under ge(af) naliya - taking out old unserviceable lt cable of any size any type from trench/duct/ poles / roof/pipe etc and keeping aside for segregation of serviceability. serviceable cable will be re-laid at same place or other place as required complete all as specified and directed., supply, laying and connecting xlpe insulated, armoured, heavy duty electric cable multi stranded aluminum conductors, 1100v grade, of size 06 sqmm 2core with proper size of lugs and laid in trenches / ducts / through gi pipe / fixed to poles etc complete all as specified and directed. note: excavation earthwork, cable covers, sand cushioning and gi protection pipe shall be measured and paid separately under relevant item., all as per serial item number 2.00 here-in-before but of size 16 sqmm 4 core., all as per serial item number 2.00 here-in-before but of size 35 sqmm 3.5 core, all as per serial item number 2.00 here-in-before but of size 50 sqmm 3.5 core, all as per serial item number 2.00 here-in-before but of size 70 sqmm 3.5 core, all as per serial item number 2.00 here-in-before but of size 95 sqmm 3.5 core, re-laying of old serviceable cable of any size obtained from item above. note:- excavation earthwork, cable covers, sand cushioning and gi protection pipe shall be measured and paid separately under relevant item., excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth and getting out in soft/ loose soil, for laying of under ground electric cable, pipes etc complete all as specified and directed. note:-(i) authorised width & depth shall only be excavated, measured and paid as specified in clause 3.2.3 of ssr part ii and 19.74.1 of ssr part i for cable/pipe laying portion.(ii) serviceable pcc /rcc cable cover obtained during excavation shall be stacked separately carefully without any extra cost to the deptt., material and labour for river bed sand filling in trenches/ ducts 15 cm above cable and 8 cm under the cable for cushioning/protection to cable including spreading, leveling and get thick 18cm after hand punning complete all as specified and directed, laying only serviceable un-reinforced precast concrete cable cover class lv, type 1, flat, of 250 mm x 150 mm x 40 mm obtained from trenches, abetting each other with gap between adjacent slab not exceeding 10 mm over under cable for protection complete all as specified and as directed., supply and laying un-reinforced precast concrete cable cover, class lv, type 1, flat, size 250 mm x 150 mm x 40 mm abetting each other with gap between adjacent slab not exceeding 10mm over under cable for protection complete all as specified and as directed., returning, filling in, including spreading, leveling, watering and well ramming in layer not exceeding 25cm thick each complete all as specified and directed., removing excavated soil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.50 metre above the starting point complete all as specified and directed., material and labour for cutting under the road /pavement /hard standing or in any other situation with the manual labour for crossing of u/g cable through it and making both the end good complete all as specified and directed ., supply and laying gi water tubing of 80 mm bore, light grade, is-1239 marked with all fittings is marked and laid in trenches/under roads/in drains with suitable size flat iron/gi clamps, bolts, nuts and washers etc for cable protection complete all as specified and directed., supply and laying gi water tubing of 50 mm bore, light grade, is-1239 marked with all fittings is marked and laid in trenches under roads/in drains, fixed to poles/walls with suitable size flat iron/gi clamps, bolts, nuts and washers etc for cable protection, complete all as specified and directed ., supply and laying gi water tubing of