Get complete information related to latest Oil Discharge Tube Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Oil Discharge Tube Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Oil Discharge Tube Tenders.
Tender For supply of supply of cassette ac, 3.0 tr bee 4-star or higher inverter ac , supply of hi-wall split ac, 1.5 tr bee 5-star inverter ac , supply of hi-wall split ac, 1.0 tr bee 5-star inverter ac , installation of 3.0 tr cassette ac , installation of 2.0 or 1.5 or 1.0 tr hi-wall split ac , supply and installation of copper refrigerent for 3.0 tr cassette acs , supply and installation of copper refrigerent pipes for 1.5 or 1.0 tr sacs , supply and installation of interconnecting wires for 3.0 tr cassette acs , supply and installation of interconnecting wires for 1.5 or 1.0 tr hi-wall split acs , supply and installation of 25 mm pvc drain pipes , supply and installation of 32 mm pvc drain pipes , supply and installation of ms angle for outdoor units , supply and installation of 4kva stabliser , supply and installation of 5.0 kva stabliser
Tender For corrigendum : tender for supply of supply of cassette ac four way capacity 2point5 tr minimum 3 star rating inverter type rotary or scroll compressor aircooled condensing unit with copper cooling coil refer annexureiii-a , supply of cassette ac four way capacity 3 tr minimum 3 star rating inverter type rotary or scroll compressor aircooled condensing unit with copper cooling coil refer annexure iii-a , supply of cassette ac four way capacity 4 tr rating inverter type rotary scroll compressor aircooled condensing unit with copper cooling coil refer annexure iii-a , supply of suitable size refrigerant grade copper piping for 2or2point5or3or 4tr cassette acorsplit ac unit refer annexureiii-a , providing flexible pvc duct hose covering pipeof size 60 mm suitable for exposed refrigerant pipes for cassttte ac units refer aneexure iii-a , providingcpvc sdr11 pipes 32 mm with 9 mm thick tube type nitrile rubber insulation for refer annexureiii-a , providing cpvc sdr11 pipes 25 mm with 9 mm thick tube type nitrile rubber insulation for condensate water drain from the ac indoor units refer annexureiii-a , supply of rain proof outdoor duty as per ip-66 electrical control panel with incommer 4 pole mccb 100 amp digital voltmeter digital ammeter indication lamps refer annexureiii-a , supply of following size lt power cable with copper conductor xlpeorpvc as directed by eic 4 core - 4 sqmm refer annexureiii-a , supply of following size lt power cable with copper conductor xlpeorpvc as directed by eic 4 core - 6 sqmm refer annexureiii-a , supply of following size lt power cable with copper conductor laying of the same in by eic 4core - 25 sqmm refer annexure-iii-a , supply of following size lt power cable with copper conductor as directed by eic 4core - 16 sqmm refer annexure-iii-a , supply of copper cable of size 4core - 2point5 sqmm for communication , supply of perforated hot dipped galvanised iron cable tray of size150 mm width x 50 mm depth x 1point6 mm thickness , supply of perforated hot dipped galvanised iron cable tray of size 300 mm width x 50 mm depth x 1point6 mm thickness , installation testing and commissioning of cassette ac four way capacity 2point5 tr minimum 3 star rating inverter type rotaryorscroll compressor aircooled refer annexure-iii-b , installationtesting and commissioning of cassette ac four way capacity 3 tr minimum 3 star rating inverter type refer annexure-iii-b , installation testing and commissioning of cassette ac four way capacity 4 tr inverter type rotary or scroll compressor units refer annexure-iii-b , erection testing and commissioning of suitable size refrigerant grade copper for 2or2point5or3or4tr cassette acorsplit ac unit refer annexure-iii-b , laying of flexible pvc duct hose covering pipe gray colour of size 60 mm suitable refer annexure-iii-b , laying of cpvc sdr11 pipes 32 mm with 9 mm thick tube type nitrile rubber insulation for condensate water drain from the ac indoor units refer annexure-iii-b , laying of cpvc sdr11 pipes 25 mm with 9 mm thick tube type nitrile rubber insulation for condensate water drainrefer annexure-iii-b , erection testing and commissioning of rain proof outdoor duty as per ip-66 electrical control panel annexure-iii-b , laying of following size lt power cable with copper conductor xlpepvc insulation pvc inner sheathed armoured extruded pvc oas directed by eic 4 core - 4 sqmm refer annexure-iii-b , laying of following size lt power cable with copper conductor xlpeorpvc insulation as directed by eic 4 core - 6 sqmm refer annexure-iii-b , laying of following size lt power cable with copper conducto as directed by eic 4 core - 25 sqmm refer annexure-iii-b , laying of following size lt power cable with copper conductor xlpeorpvcas directed by eic 4 core - 16 sqmm refer annexure-iii-b , laying of copper cable of size 4 core - 2point5 sqmm for communication , installing of perforated hot dipped galvanised iron cable tray of size150 mm width x 50 mm depth x 1point6 mm thickness
Tender For construction new rcc ohsr of 100 cum , pump chamber of size 3.05x3.70 mtr., providing, stringing out pvc pipes, household connections, water meter and painting installation of sign board etc. complete in all respect and all other works contgent there to.
Tender For corrigendum : supply of copper alloy gate valve for waterworks purpose as per is 778 (q3) , steel tubes, tubulars and other steel fittings as per is 1239 (part 2 - steel pipe fittings) (q3) , unplasticized pvc pipes for potable water supplies as per is 4985 (q3) , rotational moulded polyethylene water storage tanks as per is 12701 (q3)