Get complete information related to latest Oil Pipeline Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Oil Pipeline Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Oil Pipeline Tenders.
Tender For purchase of sports exercise physiology lap equipments - cardiopulmonary exercise testing system system should be compact can be used in laboratory operation and low maintenance costs and easy servicing. system should be state of the art computerized telemetry breath test analyzer for on-line breath by breath measurement of exercise test of respiratory system to measure following parameter: time, ve, bf(rr), hr, feo2, feco2, peo2, peco2, vo2, vco2, ve/vco2(eqco2), ve/vo2(eqo2), rq(rer), vd/vt, vo2/kg, vo2/kg/hr, met, watt(work), hr, ttot, ti, te, ti/te, ti/ttot, pef, pif, br, vet, sum, tv/te, o2 kinetics, oxygen deficit, oxygen debt parameters and indirect calorimetric. wireless hr recording system, indirect cardiac output by wassermann algorithm system should comply ats and ers guide line and it should be ce certified., iso certified system should have automatic ambient conditions measuring system. system should work under temperature range 0 to 50 celsius. system should have facility for automatic calibration of analyzers. volume transducer calibration with precision calibration syringe. system should meet following technical specification flow rate measurement: measuring headpiece should be either through turbine /dvt/ pneumotach and dead space less then 40 ml, it should not be affected by humidity , flow range +/- 18 l/s and accuracy 2% oxygen analyser : should be either electrochemicalcell/paramagnetic and measurement range 0- 100 %,response time t90 100 ms and accuracy +/-0,04 % and- resolution 0,02 %carbon dioxide analyser : should be ndir (infraredabsorption) and measurement range 0 - 10 %,-response time t90 90 ms , accuracy +/- 0,04 %, andresolution 0,02 % software should support latest windows or latest andin corporate customized predicted normal equations.software should be capable of changing graphics displays during real time testing. system should have facility for automatic treadmill or bicycle ergo meter control. should be supplied with software, standard accessories for operation manual carrying case for field use. system should be supplied with latest data acquisition system, deskjet printer and ups. system should comply en iso 13485:2003, en iso 9001:2000, ec certificate93/42/eec, programmable treadmill running machine with user terminal (display &keyboard) stand- alone and remote control via rs232 running surface: l:170 cm (minimum), w: 65 cm (minimum) maximum possible load: 200 kg (440 lbs) speed range: 0-40 km/h elevation: 25% (14 maximum elevation) motorized adjustment, reverse belt rotation. motor system 3.3 kw, single phase ac motor, maintenance free and brushless power transmission: frequency inverter, poly v- belt, very quiet operation safety system: emergency-off safety stop switch (safety lanyard with actuator, pull cord and clip); potential equalization bolt; transformer for potential-isolation from the mains ambient condition: temperature: +10to +40 degrees c, humidity 30 to 70% display (resolution): lcd display heartrate monitoring: wireless transmitter; the treadmill should be able to interface with well-known compatible metabolic gas analyzer as per standard and custom exercise protocols different programs safety harness-1. indispensable accessory for stress testing, accident prevention and for the general safety of athletes.2. safety arch with different heights and widths to fit all running machines.3. an emergency stop at the crossbar of the safety arch allows automatic stop of the running belt in the moment a fall occurs.4. the harness and chest belt (available in 5 sizes: xxs, s, m, l, xl) secure the subject and prevents falling over to the front.5. chest belt straps do not pinch or restrict the athlete", programmable ergometer functional design and excellent stability, load up to 160kg. easy to use saddle, handle bar and pedals speed independent and dependent power control handle bars are easy to change to suit different tests, rotatable by 360 degrees. mechanical/motor-assisted seat a
Tender For work of replacement of damaged gasket of hv/lv bushings and turrets and attending leakage from oilpipelines of 132/33kv, 40 mva t/f-2 (bhel make ) installed at 132 kv sub station sarila under etd hamirpur.
Tender For corrigendum : non-comprehensive annual maintenance contract (ncamc) for abb make plc system at 42 inch crude oilpipeline from chennai port trust (chpt) to cpcl manali
Tender For corrigendum : supply of goods, tools & equipmentforan international standard itotin mechanic motor vehicle (mmv) tradeat iti tarsali, gujarat, india (package 3: mmv trade) - alternator assembly used for lmv working condition demonstration kit , starter motor assembly used for lmv working condition demonstration kit , electronic engine control module , fuel pump for mpfi working condition demonstration kit , inline fuel injection pump and rotor type fuel injection pump , demonstration board of 2wheeler ignition system. , demonstration board of electronic ignition system. , working condition of petrol mpfi engine assembly with fault simulation board , mpfi petrol engine with swiveling stand along with special tools for dismantling and assembling , demonstration board of mpfi system , ultrasonic injection cleaning equipment , working model of power windows , petrol engine motorcycle/scooter along with special tools and accessories , four stroke multi cylinder diesel engine in working condition , four stroke four cylinder crdi diesel engine in working condition , functional/experiment model of different type of sensors. , auto electrical test bench , cut section model of mock layout of a motor car -electrical system - working model , cut section working model of single plate clutch assembly. , cut section working model of diaphragm clutch assembly. , cut section working model of centrifugal clutch assembly. , front axle ( rezeppa joint) with stand for dismantling and assembly , rear axle with stand for dismantling and assembly , cut section model of synchronous gear box working , cut section model of sliding mesh gearbox working , cut section model of constant mesh gearbox working , full floating axle and semi- floating axle assembly , cut section working model of automatic transmission gear box , steering assembly - , 1. rack& pinion, , 2. worm& roller , 3. recirculating ball , 4. power steering , wheel alignment set up instrument-computerized , brake testing equipment (to test efficiency of vehicle where motion after braking is plotted) , motor vehicle in running condition (diesel heavy) with hydraulic power steering , light motor vehicle diesel crdi with electronic power steering and car a/c , engine dynamometer , four stroke multi cylinder engine mpfi petrol with cng kit set up in running condition , four cylinder four stroke diesel engine test rig with rope brake dynamometer , exhaust gas analyzer - diesel , training setup for adas systems , 4-wheel alignment set & hoist with advanced driver assistance systems (adas) complete frame targets , steel toolbox with lock and key (folding type) , punch letter , outside micrometer (0 25) , outside micrometer (25 50) , outside micrometer (50-75) , outside micrometer (75-100) , inside micrometer (25-50) , depth micrometer (0-25) , thread micrometer , adjustable micrometer sprit level to measure flatness, indication and taper with prismatic measuring base , vernier caliper , digital vernier caliper , vernier depth gauge , vernier bevel protractor, least count 5minutes , telescope gauge , dial test indicator plunger type (complete with clamping devices and stand) , universal surface gauge , cylinder bore gauge , compression testing gauge suitable for petrol engine. , vacuum gauge , granite surface plate , work bench , spanners socket with speed handle, t-bar, ratchet and universal , magneto spanner set , cylinder ridge cutter , vice grip pliers , torque wrenches , pneumatic tools set , car jet washer , pipe flaring tool , pipe cutting tool , universal puller for removing pulleys, bearings , stud extractor set of 3 , stud remover with socket handle , paraffin pressure gun , hand reamers adjustable , straight edge gauge , straight edge gauge , ladle , electric soldering iron , wire gauge (metric) , digital multi meter, 3 % digit (min), diode test mode and continuity mode, , growler , hydrometer , battery analyzer with printer , carburetor - solex, mikuni for dismantling a
Tender For re babbiting-dismantling of bearings and pads from housing,rebabbiting of 10 nos tgb thrust pad along with all accessories,rebabbiting of turbine guide bearing, mid bearing & end bearing along with floating seals and all accessories,material composite test, ut test and dp test should be done for re-babbitted material,assembly of re-babbited bearings with blue match,submitting the video graphs of re-babbiting and reports of re-babbiting.re-alignment-the reason for shifting of generator shaft by 2 to 3 mm shall be analyzed and rectification works needs to be carried out,complete dismantling, assembling, painting and re-alignment of machine shaft,inspection of turbine shaft journal surface and repairs if required,inspection/replacement of worn out bushes and seals of guide vane, if necessary,inspection and repair of labyrinth ring, face plates, guide vanes and runner,guide vanes bed setting,tgb water cooler descaling work to improve the efficiency of cooler,complete assembly of machine,checking the magnetic axis of the generator and to ensure its alignment, checking of the unit leveling at all places and complete alignment of machine shaft,testing & commissioning of complete machine,painting of entire machine,checking of vibration & site balancing of machine,submission of vibration, balancing & alignment reports.flow switch-supply and installation of flow switch (flow rate110 lpm) along with 01 no 01 nc contact for inlet and outlet lubrication oilpipelines,supply and installation of pressure switch (30bar) for inlet and outlet lubrication oilpipelines,supply and installation of level switch for in tgb oil sump.replacement of new miv trunion shaft-dismantling of miv counter weight, miv servomotor assembly, and other related parts,lifting of miv from the bed,transportation of miv to the firms place, if required,replacing old nitrile rubber trunnion seals with existing profile by new one on both sides,replacements of miv trunnion shaft. providing of necessary drawings,material composite test, ut test and dp test should be done for new trunnion shaft & trunnion seals, bushes etc,all related fasteners and dowel pin to be replacing by new one,drive and non drive end trunnion bush, cupseals, stop end plate, washer ring etc need to be replacing by new one,repair of miv discand main body to be attended, if required,supply and replacement of miv disc rubber seal,pressure testing and commissioning should be carried out as per standard in presence of kpcl engineers,all tools & tackles required for the above mentioned works shall be arranged by contactor only.
Tender For supply of machine, equipment and others - list of machine and equipments, laproscopic hd camera brand - karl storz/conmed/olympustechnical specificationresolution: 1920x1200 pixes / 1900x1000 pixescable length: 300 cm, ultrasonic harmonic scalpelbrand - johnsontechnical specificationdimensions: (hxwxd) 5.3" 14.5"x15.2" voltage: 100-240 vac frequency: 50/60 hz rated current: 3 amp , ultrasonic harmonic scalpelbrand - valley labtechnical specification macrobipolar/bipolar: 473 khz sinusoid, 100% duty cycle. seal: 473 khz sinusoid pulsed , hand instruments for laproscopy brand- karl storz/ olympustechnical specification i) veress needle: it should be with spring action blunt style -12 cm: 1 no 10 cm: 1 no 8 cm: 1 no ii) trocar and cannula: 10 mm: 2 nos 7 mm: 1 no. 5 mm 6 nos it should consists of trocar, cannula with insufflation and multifunctional valve and must have pyramidal tip. iii) reducer/reduction sleeve 5 mm. 1 no iv) telescopes: 10 mm- 0 - 1 nos -30 - 1 nos 5 mm-30 1 nos rigid rod lens system provides good resolution and the better dept perception. it should have uniform image brightness and autoclavable. the 300 forward oblique angle and permits for greater latitude for viewing underlying areas under difficult anatomical conditions. v) suction cannula: 10 mm - 1 no 5 mm -1 nos vi) laparoscopic scissors: curved (monopolar metzenbaum dissector 5mm diameter): 1 nosstraight (bipolar): 1 nosperitoneal scissor: 1 nosvii) unipolar forceps (hook & spatula): 2 nos viii) bipolar forceps : 2 nos ix) atraumatic forceps: maryland dissector forceps: : 2 nos. fenestrated forceps: : 2 nos. x) needle holder (flat jaw) with handle : 2nos xi) monopolar cable (reusable):1 nos. xii) bipolar cable (reusable): 1 nosxiii) allis (double row of teeth) grasper: 1 nos xiv) aspiration needle: 1 nos. xv) reducer/ reduction sleeve (5mm): 1 nos xvi) grasping forceps (toothed & rachet 5mm): 2 nos xvii) laparoscopic knot pusher: 1 nos xviii) clip applicator (reusable): 5mm -: 1 nos : 10 mm: ino xix) uterine manipulator: 1 nos xx) clips( medium & large) xxi) drilling needle: 1 nosxxii) infiltration needle: 1 nos xxiii) biopsy forceps (toothed punch biopsy): 1 nos xxiv) myoma fixation screw: 2 nos xxv) tissue morcellator with base unit & accessories: 1 nos , dual wavelenght laserbrand- zeisstechnical specification laser type: diode, semiconductor wavelength : 1470nm+635nm max power: 15 watts/1470nm+5mv/635 aiming beam : 635nm/1, 4mw max or 515nm/2, 5mw max operation mode : continuous or modulated pulsed time : 0.05ms-1000ms beam delivery : sma905 connector optic fiber compatible : optic fibers having a core from 200um to 1000um, na=0.22~0.48 beam emission initiation : footswitch controller :microprocessor display : 10.1" ips with touch panel medical approved cooling : internal, air and thermoelectric cooling power supply of the laser: dc 24v/8.33a from the separate ac power supply of ac adapter : single phase 100-240va; 50-60hz, max 90w ac adapter dc 24v/8.33a medical approved laser dimensions: 27cm*24,5cm x 9cm laser weight: 2.75kg laser case dimensions : 53cm x 38cm x 23cm weight of laser with cases : 9kg environmental conditions during work : from +10 to 24 c degree, relative humidity from 30% up to 60% cass of medical device iib laser safety class 4 electric safety class i type b housing protection degree ip20b , hd camera setbrand- karl storz/ olympustechnical specification (i) hopkinsa forward-oblique telescope 30a, diameter 4 mm, length 30 cm, a utoclavable, fiber optic light transmission incorporated, color code ed : 1 nos(ii) telecam c3 : 1 nos(iii) image1 st hx one-chip full hd camera head, 50/60 hz, fixed focus, prog ressive scan, soakable, gas-and plasmasterilizable, focal length f = 16 mm, 2 freely programmable camera head buttons, for use with image1 x-link tc301, tele pack + and tp101 : 1 nos(iv) medical grade surgical monitor - fhd : 1nos(v) cold light fountain power led 175 scb, with integrated karl storz-scb, high-perfo