Get complete information related to latest Oil Tank Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Oil Tank Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Oil Tank Tenders.
Tender For supply of overhauling & maintenance of cp transformer rectifier units , ac amp. meter, for detailed description refer price breakup sheet , ac volt meter, for detailed description refer price breakup sheet , dc volt meter, for detailed description refer price breakup sheet, dc amp. meter, for detailed description refer price breakup sheet, voltmeter ( psp meter ), for detailed description refer price breakup sheet, main rectifier diodes, iav 150 amp, piv - 1200 v , type- 150 lf 120 , "lightning arrestor( la) both input and output side, rms voltage rating - 500v ,rms current rating - 1.5 ka, type- lt 0.5 oe eqv", thyrister module (scrm) consisting two antiparrallel thyrister, for detailed description refer price breakup sheet, auxiliary transformer for control circuit power supply, for detailed description refer price breakup sheet, filter capacitor bank in dc output , 2500 micro farad , 150v x 6 electrolytic capacitors, relay for providing remote contacts for mcb tripped & ac supply fail faults , coil - 240 v ac coil resistance 10 k contacts 2no+2nc , 8 pin plug in type, relay for providing remote contacts for oiltank or instrument , chamber high temp. fault. coil - 240 v ac coil resistance 10 k contacts 3no+3nc , 11 pin plug in type, thermostate with adjustable temp. setting with nc contacts ( 30 to 110 setting ), indicator lamp , housed in 22.5 mm dia, 240 v, led type red colour, auto or manual mode selector rotary type, 4 pole , 2 way ,63 amps, 240 v, ac type srpm 5417b or pa 17463b, coarse manual output control switch , rotary type, 1 pole , 6 way ,63 amps, 240 v, ac type pa7163f, fine manual output control switch rotary type, 1 pole , 4 way ,63 amps, 240 v, ac type srpm 615dor pa 5163 d, coarse current limit settor switch cam type, 2 pole ,6 way ,6 amps, 240 v, type s6-61072, fine current limit settor switch, cam type, 2 pole ,6 way ,6 amps, 240 v, type s6-61072, reference electrode selector switch, cam type 2 pole ,4 way ,6 amps, 230 v, type s6-61070, local or remote control mode selector switch,toggle type 2 pole , 2 way ,6 amps, 240 v, , on or off toggle switches in various lamp and meter circuits. 1/2 pole , 2 way ,6 amps, 240 v, , current transformer for ammeter a1 ratio - 50/1, burden - 5 va ,class - 1, contactor 32 amp.bch make 3p +(1p no) with add on 240 v ac coil , breather ( 19.45 mm dia), output voltage setter potentiometer in local auto mode 2.5 k ohm 3 watt ww, output current setter potentiometer in local auto mode 1 k ohm 3 watt ww, oil temp. indicator range ( 0 to 150 o c ), 4-20ma converter module for dc output voltage signal input - 0-75v dc , output - 4 to 20 m a , max load - 600 ohm , accuracy - +-0.5 %, aux supply - 240 v, ac type-520 t, base or channel mounting type , 4-20ma converter module for dc output current signal input - 0-75a (75 mv) dc , output - 4 to 20 m a , max load - 600 ohm , accuracy - +-0.5 %, aux supply - 240 v, ac type-520 t, base or channel mounting type , "auto transformer with coarse and fine tappings for manual control dc of output, input -265 v , coarse taps- 7 nos. fine taps- 04 nos. capacity - 8000 va, insulation - class -a (oil cooled ) ", "main transformer with shield double wound primary- 240 +/- 10 %, secondary- (0-110 v), capacity - 10,000 va, insulation - class -a (oil cooled )", filter choke in dc output , 7.5 mh at 100 amp., control box for card fixing ceco-108 & ceco 105 d1 (and extra card connector having 40 slots), current or voltage control firing card control card , type- ceco- 105d1 , "remote control interface card control card ,type- ceco -108 ", "current limit setter card control card , type- ceco -35a- 2.5 v , 75a/75mv -33.33", "voltage current sensor card control card , type -ceco -19c ", pulse driver card ceco - 118 c, surge suppressor r-c network across scrs 75 ohm, for detailed description refer price breakup sheet, "fuse fail indicator module for diodes and output fuses six channel type with led indicators and 1 common no+nc contacts ,sensing
Tender For mtps-i tm unit-i to iv dismantling, cleaning and assembling of main oiltank filters and centrifuges bowl assembly during 2026-27 for a period of one year from the date of commencement.
Tender For corrigendum : providing of custom bid for services - annual contract for unloading of domestic , imported coal rakes ( bobr or boxn), oil rakes (btpn) and road oiltanker at rtps dvc for 2(two) years
Tender For supply of signage board for earth pit board , electric shock treatment chart , signage board for assembly point board , danger board , danger plate 11kv , danger plate 440 v , oiltank for diesel generator sign board , no smoking sign board 8 x10 inch
Tender For mtps i tm unit i to iv dismantling cleaning and assembling of main oiltank filters and centrifuges bowl assembly during 2026 27 for a period of one year from the date of commencement
Tender For hiring of one private oiltanker of 12 kl capacity, fitted with pump & calibrated flow - meter of minimum dispensing capacity @ 200 l/min from rcd kgp to fueling point at nmp & bls round the clock for a period of (01) one year through open tender.