Web Analytics Made Easy - StatCounter

Omr Scanner Sale Tenders

Get complete information related to latest Omr Scanner Sale Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Omr Scanner Sale Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Omr Scanner Sale Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

CTN :38033440 Due date: 27 Jan, 202527 Jan, 2025 NA
Tender For bid to ras supply of cctv system and accessories - 5mp ip network tdn low light ir rugged bullet camera motorized zoom , 5mp ip network tdn low light ir rugged bullet camera , outdoor 128 inch cmos 2mp or better ir ptz camera , 64 channel nvr 8 sata embedded linux based , 85inch lfd colour led screen , managed switch 8 port poe gbps with 2 sfp fiber , sfp module , optical fibre patch code lc to lc type 1 meter single mode , outdoor 6u rack pole mounting including all accessoories complete as required , wall mount rack 9u 630mm deep , online ups 2 kva with 1 hour back , 10 tb harddrive surveillance , hdmi cable 8k supported , rj 45 connectors , boom barrier smart checking solution with upto 6 mtr length , uhf rf id reader for four wheeler check in and check out , ms pole with branding box and l arm for uhf reader , software for fastag for uhf fastag rfid , visitor management system , uhf reader tag for cars and bike checkin and checkout , qrface recognition device biometric , software rfid boom barrier management work station i7 11700 8 core , conduiting wiring cabling for cctv system

Central Government/Public Sector

CTN :39007294 Due date: 10 Feb, 202510 Feb, 2025 NA
Tender For laboratory ( part-1 of 2 ) - anti b blood gr.serum (monoclonal)unit of 5 ml bulb, 1 unit, 4, elisa reader instrument should have a windows-based operating system., instument should be compatible with u, v and flat microwell strips., instrument should have up to100 programmable locations for different parameters., instrument should have 8 independent channel optical systems., instument should have programmable speed and time for plate shaking., instument should take five seconds to measure the entire plate., instument should have option to run 12 assays in one plate, instument should have 4 preinstalled filters and option to upgrade 4 optional filters., measuring range of the instrument should be 0.000 to 4.000., instument should have a resolution of 0.0001 od., system should have option for external printer., the system should have single and dual wavelength measurement options., system should have specific dedicated information management software., system should have unlimited results storage facility., systemshould have facility for plate templets. plate templets must allow positioning of control, calibrators, blanks, and samples at any location on the plate with lab custom patient ids and names., the system should have qc programme facilities with west-guard rule.,, 1 unit, 8, 0.1 n hclready to use for hemoglobin estimation by sahlis method stablear/gr/sxcellar quality with all assay details, 1 unit, 12, 3 cell panel for antibody screening - a panel of 3percentage reagent red blood cells for quality control of anti-human globulin procedure (coombs control cells), pack size should be of 2 ml each., company should provide qc report with each vial supplied., 60 t, 16, a.p.t.t.ready to use stable reagents method mechanical/manual clot detection systems diagnos aptt reagent calcium chloride (0.02 mol/l) tsc solution, 5ml, 20, abl90 flex solution pack (680) abl 90 radiometer, 1 unit, 24, ace (angiotensin converting enzyme) pack for diasysfully automatic biochemistry, 5litre/pack, 28, actin (10 x 10ml) fully automatic cougulation analyser cs-2400, 1 unit, 32, actin fsl (10x10ml) fully automatic cougulation analyser cs-2400, 1 unit, 36, ada eco for diasys, 1 unit, 40, agar agar powderdehydrated powder, 1 unit, 44, alat (gpt) fs (ifcc mod.) syspack sys for diasys fully automatic biochemistry sys, 4 x 25 ml, 48, albumin bcg eco for diasys, 4 x 32 ml, anti b blood gr.serum (monoclonal)unit of 5 ml bulb, 1 unit, 4, elisa reader instrument should have a windows-based operating system., instument should be compatible with u, v and flat microwell strips., instrument should have up to100 programmable locations for different parameters., instrument should have 8 independent channel optical systems., instument should have programmable speed and time for plate shaking., instument should take five seconds to measure the entire plate., instument should have option to run 12 assays in one plate, instument should have 4 preinstalled filters and option to upgrade 4 optional filters., measuring range of the instrument should be 0.000 to 4.000., instument should have a resolution of 0.0001 od., system should have option for external printer., the system should have single and dual wavelength measurement options., system should have specific dedicated information management software., system should have unlimited results storage facility., systemshould have facility for plate templets. plate templets must allow positioning of control, calibrators, blanks, and samples at any location on the plate with lab custom patient ids and names., the system should have qc programme facilities with west-guard rule.,, 1 unit, 8, 0.1 n hclready to use for hemoglobin estimation by sahlis method stablear/gr/sxcellar quality with all assay details, 1 unit, 12, 3 cell panel for antibody screening - a panel of 3percentage reagent red blood cells for quality control of anti-human globulin procedure (coombs control cells), pack size should be of 2 ml each., company shoul
 Loading, Please wait...

Connect us via What's Up