Get complete information related to latest Operating Instrument Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Operating Instrument Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Operating Instrument Tenders.
Tender For supply of medicine to be purchased - cap evion 400 mg , tab norflox 400 mg , tab zifi 200 mg , tab clavam 625 mg , tab zerodol p , tab zerodol sp , tab calpol 650 mg , oint omnigel 15 gm , uric acid kit 4x24 4x6 ml , sgpt kit 4x24 4x6 ml , accucheck active glucostrip 1x50 , sgot regent kit 4x24 4x6 ml , s bilirubin t and d kit 4x60 ml , glucose regent kit 2x200ml , urine stirip 1x100 , borosil glass test tube , hiv test kit , pregnancy test kit , s triglyceride kit kit 4x24 4x6 ml , s cholesterol kit 5x30 ml , albumin kit 5x50 ml , alk phosphatase 4x24 ml 6x6 ml , blood group kit 3x10 ml , ecg gelly 250 ml , ecg paper bpl 9108 210x295x100 , dispo syringe 3 cc , dispo syringe 10 cc , dispovan needle 24 g , latex exam gloves powdere medium , latex exam gloves non powdered medium , nitrile gloves medium
Tender For procurement of 03 types of accessories items for the department of obstetrics and gynecology on a pac basis at aiims bhubaneswar- , hopkins forward oblique telescope 30 degree, diameter 10 mm, length 31cm , hopkins forward oblique telescope 30 degree, diameter 4mm, length 30cm , betochi operating seath, size 5.4mm, with channel for semigrid 5fr operatinginstruments with i stopcock and luerlock adaptor
Tender For diagnostic and therapeutic items for cardiac cath lab (group b) - manifold with two side ports for ptca (fda/ce approved), manifold with three side ports for ptca (fda/ce approved), teflon coated guide wires (j-tip & straight-tip) standard length-145 or 150cm (fda/ce approved), teflon coated guidewires(j-tips & straight-tip) exchange length-260 or 300cm (fda/ce approved), femoral introducer sheath with puncture needle for adults (sizes 5 - 11 fr.) standard length; 10-16-25 cm long; 0.021 or 0.025-inch guide wire compatible. material of sheath tubing should be made of etfe, cross cut valve should be made up of silicon rubber & should have silicone coating. dilator tube should be made up of polypropylene and should have silicon coating. must have with haemostatic crosscut valve; with integrated side arm with attached 3-way stopcock; with suture eye for securing sheath and click sound; kink resistant. must have with dilator-hub lock mechanism to prevent its back-out during insertion; pack must include with or without metallic needle usfda approved, long introducer sheath (20-50cm long) (fda/ce approved), extra-long introducer sheath (>50 cm) (fda/ce approved), radial introducer kit with puncture needle for adults (sizes 5 - 7 fr.) standard length 7 cm long; 0.035 or 0.038-inch guide wire compatible, include surflash 20g*2 entry needle (plastic iv catheter) and 0.025 mini plastic guidewire must have etfe sheath tubing, dilator tube should be made up of polypropylene and should have silicon coating.should contain a haemostatic crosscut valve to prevent back leak of blood and aspiration of air; with integrated side arm with attached 3-way stopcock., trans radial coronary diagnostic catheter (us fda approved) of various lengths, syringe for pressure injector-150ml with pressure tubing compatible with the available system in the cath lab(medred-mark-7) arterion, high pressure connecting tubing up to 50 cms long for pressure syringe, a). coronary diagnostic angiography catheter(judkins type- left and right) (us fda, b). coronary diagnostic angiography catheters ( judkins type) europeance approved), a). diagnostic coronary angiography catheter(amplatz type- left and right) (us fda), b). diagnostic coronary angiographic catheter ( amplaz type left & righce approved), pigtail catheters (fda/ce approved), short pigtail for pericardiocentesis, diagnostic multipurpose catheters (fda/ce approved), nih catheter (fda/ce approved), ima catheter (fda/ce approved), ptca inflation device-analog display (balloon inflationdevice analog display, 30 atm pressure with tubing and 3way stopcock) (fda/ce approved), y-connector set with extension tubing tuohy burst, pci,needle and 3-way, special y-connector set with both fixed and haemostaticvalve with upto 10 fr inner diameter, pci needle with/without torquer device, disposable plastic sterile luer lock syringer for angiography and ptca (leur lock), large lumen ptca guiding catheters of 5 to 8 fr sizes-fda approved, large lumen ptca guiding catheters of 5 to 8 fr sizes-ce approved, brk needle (fda/ce approved) for paediatrics/adults, embolic protection (distal protection) device (epd) for ptca (fda approved), embolic protection (distal protection) device (epd) for ptca (ce approved), manual thrombosuction catheter for ptca (fda approved), manual thrombosuction catheter for ptca (ce approved), radial artery compression device, cross over arterial sheaths(fda approved), snare loop (fda approved), snare loop (ce approved), micro grabber (fda approved), micro grabber(ce approved), intra vascular retriever snare of various sizes with single foldable loop, intra vascular retriever snare-two loops (gooseneck type), intra vascular retriever snare-three or more loops (gooseneck type), pericardiocentesis kit (fda/ce approved), pigtail catheter with multiple markers (fda approved), rotalink plus system, rotalink pro system, rotalink guidewire, intracoronary pressure wire (ffr) for ptca-compatible with
Tender For corrigendum : diagnostic and therapeutic items for cardiac cath lab (group b) - ecgelectrodesofhighqualitymaterialtominimize interference and signal distortion during prolonged cardiology procedurest (fda/ce approved), manifoldwithtwosideportsforptca(fda/ce approved), manifoldwiththreesideportsforptca(fda/ce approved), tefloncoatedguidewires(j-tip&straight-tip)standard length-145 or 150cm (fda/ce approved), tefloncoatedguidewires(j-tips&straight-tip)exchange length-260 or 300cm (fda/ce approved), femoral introducer sheath with puncture needle for adults (sizes 5 - 11 fr.) standard length; 10-16-25 cm long; 0.021 or 0.025-inch guide wire compatible. material of sheath tubing should be made of etfe, cross cut valve should be made up of silicon rubber & should have silicone coating. dilator tube should be made up of polypropylene and should have silicon coating. must have with haemostatic crosscut valve; with integrated side arm with attached 3-way stopcock; with suture eye for securing sheath and click sound; kink resistant. must have with dilator-hub lock mechanism to prevent its back-out during insertion; pack must include with or without metallic needle usfda approved, longintroducersheath(20-50cmlong)(fda/ce approved), extra-longintroducersheath(>50cm)(fda/ceapproved), radial introducer kit with puncture needle for adults (sizes 5 - 7 fr.) standard length 7 cm long; 0.035 or 0.038-inch guide wire compatible, include surflash 20g*2 entry needle (plastic iv catheter) and 0.025 mini plastic guidewire must have etfe sheath tubing, dilator tube should be made up of polypropylene and should have silicon coating.should contain a haemostatic crosscut valve to prevent back leak of blood and aspiration of air; with integrated side arm with attached 3-way stopcock, transradialcoronarydiagnosticcatheter (us fda approved) of various lengths, syringeforpressureinjector-150mlwithpressuretubing compatiblewiththeavailablesysteminthecathlab(medred-mark-7)arterion, highpressureconnectingtubingupto50cmslong for pressuresyringe, a). coronarydiagnosticangiographycatheter(judkinstype- leftandright)(us fda, b). coronary diagnostic angiography catheters ( judkins type) europeanceapproved), a). diagnosticcoronaryangiographycatheter(amplatztype- leftandright)(us fda), b). diagnostic coronary angiographic catheter ( amplaz type left &righceapproved), pigtailcatheters(fda/ceapproved), shortpigtailforpericardiocentesis, diagnosticmultipurposecatheters(fda/ceapproved), nihcatheter(fda/ceapproved), imacatheter(fda/ceapproved), ptcainflationdevice-analogdisplay(ballooninflation, deviceanalogdisplay,30atmpressurewithtubingand3, waystopcock)(fda/ceapproved), y-connectorsetwithextensiontubingtuohyburst,pci, needleand3-way, specialy-connectorsetwithbothfixedandhaemostatic, valvewithupto10frinnerdiameter, pcineedlewith/withouttorquerdevice, disposableplasticsterileluerlocksyringerfor angiographyandptca(leurlock), largelumenptcaguidingcathetersof5to8fr sizes-fda approved, largelumenptcaguidingcathetersof5to8fr sizes-ce approved, brkneedle(fda/ceapproved)for paediatrics/adults, embolicprotection(distalprotection)device(epd)for ptca (fda approved), embolicprotection(distalprotection)device(epd)for ptca (ce approved), manualthrombosuctioncatheterforptca(fda approved), manualthrombosuctioncatheterforptca(ceapproved), radialarterycompressiondevice, crossoverarterialsheaths(fdaapproved), snareloop(fdaapproved), snareloop(ce approved), micrograbber(fda approved), micrograbber(ceapproved), intravascularretrieversnareofvarioussizeswithsingle foldable loop, intravascularretrieversnare-twoloops(gooseneck type), intravascularretrieversnare-threeormoreloops (gooseneck type), pericardiocentesiskit(fda/ceapproved), pigtailcatheterwithmultiplemarkers(fdaapproved), rotalinkplussystem, rotalinkprosystem, rotalinkguidewire, intracoronarypressurewire(ffr)forptca-compatible with abbott vascular, ivuscatheterforcoronaryinterventionscompatiblewith boston scientific vasc
Tender For kits chemical reagent glassware etc - reagents/kits/ chemical/glassware/ polyware etc items, anti-a antisera, monoclonal blood grouping lgm antibody for slide and tube method for abo blood groupingvial of 10 ml and storage at +2to +8 c. titer >1:256 with a cell and negative with b cell.avidity should be 4sec. should be validated by nib/ec/aabb/fda. demonstration of item is must for final technical approval., anti b antisera, monoclonal blood grouping lgm antibody for slide and tube method for abo blood groupingvial of 10 ml each and storage at + 2 to + 8 c. titer >1:256 with b cell and negative with a cell. avidity should be 4sec. should be validated by nib/ec/aabb/fda. demonstration of item is must for final technical approval., anti d antisera, lgm and lgg combination, , monoclonal lgm and lgg blood typing antibody for slide and tube methodfor rh blood typingvial of 10 ml each and storage at+ 2 to + 8 c. titre >1:256 with rh positive cell. avidity should be 10 sec. should be validated by nib/ec/aabb/fda . demonstration of item is must for final technical approval., anti-ab antisera, monoclonal blood grouping lgm antibody for slide and tube method for abo blood grouping vial of 10 ml each and storage at + 2 to + 8 c . titer >1:256 with a cell and with b cell. should be validated by nib/ec/aabb/fda. demonstration of item is must for final technical approval., anti d antisera, monoclonal lgg only, antibody only for tube methodfor weak d testing. titre > 1:32 and specificity : - 100% to rho(d antigen). avidity should be 5 sec.vial of 10 ml each. should be validated by nib/ec/aabb/fda. demonstration of item is must for final technical approval., anti-a1 lectin, monoclonal lgm antibody for tube method to differentiate a1 red cell antigen from a2 antigen.vial of 5 ml each . should be validated by nib/ec/aabb/fda. demonstration of item is must for final technical approval., anti h lectin, monoclonal lgm antibody for tube methodvial of 5ml each and storage of+ 2 to + 8 c. titre~~ 1:16 with o group cells and negative reaction with oh phenotype. should be validated by nib/ec/aabb/fda . demonstration of item is must for final technical approval., anti human globulin (coombs sera) polyspecific, containing anti lgg and anti c3dto detect lgg antibodies as in cross matching, dat and iat testsvial of 10 ml each and storage at+ 2 to + 8 c. ahg should give 2+/3+/4+ reaction with coombs control cell and negative reaction with any std cell. should be validated by nib/ec/aabb/fda . demonstration of item is must for final technical approval., bovine serum albumin 22% solution for serological applications, protein concentration and ph should be adjusted to 22% and 7.1(+/- 0.2%) respectivelyto enhance immunological reactions and increase test sensitivity. should be validated by nib/ec/aabb/fda . vial of 10 ml each and storage at+ 2 to + 8 c. demonstration of item is must for final technical approval., fourth generation elisa kit for anti-hcv .microplate coated with recombinant/synthetic peptide antigens for core ns3, ns4 & ns5 and antibody to hcv core antigen.niv/ who gmp qualified sensitivity: 99.5% and specificity: > 99.8% antibody (lgg and lgm detection. demonstration of item is must for final technical approval., fourth generation elisa kit for detection of hiv p24 antigen & anti-hiv 1/2 antibody. niv/ who gmp qualified sensitivity: 99.5% and specificity: > 99.8% antibody (lgg and lgm detection). analytical sensitivity 08 iu/ml for p24 antigen demonstration of item is must for final technical approval., fourth generation/ third generation elisa kit for hepatitis b surface antigen and lgg and lgm detection . niv/ who gmp qualified sensitivity: 99.5% and specificity: > 99.8% antibody (lgg and lgm detection). analytic sensitivity 50 picogram/ml demonstration of item is must for final technical approval., rapid test kits anti-hiv fourth generation for p24 antigen & antibody detection.(principal of enzyme immuno assay, agglutination, or a
Tender For online tender for the rate contract for the supply of medical drug consumables to various hospitals of government of haryana for a period of two years for group c - urine screening through dry chemistry rapid testing kit/strips for multiple drug uses:- 1. morphine/ opiates 2. buprenorphine 3. tramadol 4. d. propoxyphene 5. benzodiazepines test kit kit, dodecylbispropylene triamine 9.2gm, didecyldimethyl ammonium chloride 13.0 gm for fogging, 5 liter pack, potassium peroxomonosulphate 50% w/w containig aldehyde free disinfectant, 5 kg, cetrimide solution 20% conc. for dilution, 500 ml plastic bottle, i.o dye (rhex id dye) each (indigo blue dye), carbolic acid 400 ml, ultrasound jelly 200 ml bottle, pedeatrics iv drip set with air vent, chlorhexidine solution 5% conc. for dilution, 500 ml, skin traction set standard size, gentian violet (methylrosanilinium chloride paint preparation aqueous solution 0.5%w/v), 50 ml dark bottle, hydrogen peroxide solution 6%, 400 ml bottle, ecg jelly 200 ml bottle, nitrous oxide inhalation, potassium permanganate crystal for solution 100 gm, balance salt solution (bss for eye surgery) 500 ml, troponin t, sensitivity:-not less than 95.8%, direct whole blood test kit, bleaching powder containg not less then 30% w/w of avialble chlorine, 1 kg, epidural set, posterior chamber pmma iol optical diameter 6mm, overall length 12.5 mm, optic design biconvex,360 degrees posterior square edge and uv protection should be there, dioptric range +23d, posterior chamber pmma iol optical diameter 6mm, overall length 12.5 mm, optic design biconvex,360 degrees posterior square edge and uv protection should be there, dioptric range +22d, posterior chamber pmma iol optical diameter 6mm, overall length 12.5 mm, optic design biconvex,360 degrees posterior square edge and uv protection should be there, dioptric range +24d, chest tube with water seal no.32, posterior chamber pmma iol optical diameter 6mm, overall length 12.5 mm, optic design biconvex,360 degrees posterior square edge and uv protection should be there, dioptric range +17d, posterior chamber pmma iol optical diameter 6mm, overall length 12.5 mm, optic design biconvex,360 degrees posterior square edge and uv protection should be there, dioptric range +25d, spc set (suprapubic catheter set), posterior chamber pmma iol optical diameter 6mm, overall length 12.5 mm, optic design biconvex,360 degrees posterior square edge and uv protection should be there, dioptric range +18d, mr cannula no. 5, guide wire teflon coated v straight tip, endotracheal tube, uncuffed no. 3.0 specification: sterile, single use, medical grade pvc, transparent, murphy eye at distal end with polished smoothness, radio-opaque line throughout the length, standard 15 mm connector at proximal end. curved blister pack suiting the magill curve. internal diameter: 3.0mm -, endotracheal tube, uncuffed no. 3.5 specification: sterile, single use, medical grade pvc, transparent, murphy eye at distal end with polished smoothness, radio-opaque line throughout the length, standard 15 mm connector at proximal end. curved blister pack suiting the magill curve. internal diameter: 3.5mm -, albendazole chewable tablets 400 mg(the chewable tablets shall also comply with the test for disintegration and dissolution as per monograph given in international pharmacopeia as per requirement of goi)