Get complete information related to latest Optical Bench Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Optical Bench Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Optical Bench Tenders.
Tender For supply and installation of laboratory equipment experimental setup for fyimp ug practical classes at the department of physics, gauhati university - laboratory equipments/experiment set ups, experiment name: to verify the law of malus for plane polarised lighttechnical specifcations:i. light source: - led: 532 nm or 635 nm ( 2 nm stability), 1 5 mw adjustable output. - unpolarized (extinction ratio >500:1). - collimated beam (divergence 0.5 mrad); qty-1ii. polarizers- glan-thompson or polymer film. - extinction ratio 10 :1 @ operating wavelength.- mounted in 50 mm rotation holders.; qty-2iii. rotation stage- motorized analyzer rotation (0.05 resolution). - accuracy: 0.1 . - range: 0 360 (continuous).; qty-1iv. photodetector- silicon photodiode (400 1100 nm). - linearity: r 0.999 (0.1 w 5 mw).- digital readout: 0.1 w resolution.; qty-1v. opticalbench-- anodized rail ( 60 cm) with kinematic mounts. - vibration-damping feet.; qty-1, experiment name: to determine thespecific rotation of sugar solution using polarimetertechnical requirementsa.core instrumenti. light source- - sodium d-line (589.3 nm) or tunable led ( 2 nm stability). - output stability: 0.2% drift/hour.ii. polarizer/analyzer- glan-thompson prisms or high-grade polymer film. - extinction ratio 10,000:1 at 589 nm.iii. rotation stage- motorized with 0.001 resolution.- accuracy: 0.005 .- range: -90 to +90 .iv. sample cell-- borosilicate glass tubes with precision ground ends. - path lengths: 0.5 dm, 1.0 dm, 2.0 dm ( 0.01 dm tolerance). - temperature-controlled jacket (5 50 c 0.1 c).v. detector- photomultiplier tube (pmt) or low-noise photodiode. - linearity: r 0.999 over 0.1 w 5 mw rangevi. enclosure- light-tight with vibration damping. - internal black anodized surfaces.b.measurement specificationsi. specific rotation: range: -180 to +180 resolution: 0.001 accuracy: 0.01 ii. concentration-range: 0.01 0.5 g/ml (sucrose in water) detection limit: 0.001 g/mliii. temperature control-stability: 0.1 c at 20 c (standard condition), experiment name: to determine the wavelength and velocity of ultrasonic waves in a liquid (kerosene oil, xylene, etc.) by studying the diffraction through ultrasonic gratinga.core componentsi. ultrasonic generator- - frequency range: 1 10 mhz ( 0.1% stability). - adjustable output: 0 50 w. - digital display (resolution: 0.01 mhz).ii. transducer- piezoelectric (pzt) crystal, resonant at 2 5 mhz. - liquid-coupled design for efficient energy transferiii. liquid cell- optical glass (low thermal expansion). - dimensions: 100 50 50 mm (l w h). - sealed with quartz windows.iv. light source- he-ne laser (632.8 nm, 2 mw) or sodium lamp (589.3 nm). - beam collimation: 0.5 mrad divergence.v. optical system- adjustable slit (10 500 m). - collimating lens (f = 150 mm, 50 mm). - precision rotation stage for detector (0.01 resolution).vi. detection system- photodiode/pmt detector with linear response (400 800 nm). - traveling microscope (0.01 mm resolution) or ccd camera ( 5 mp).b.measurement specificationsi.wavelength ( )range: 0.1 2 mm, resolution: 0.001 mm, accuracy: 1%ii. velocity (v)range: 800 2000 m/s (liquids) resolution: 1 m/s accuracy: 2%iii. diffraction angles- measurement range: 30 resolution: 0.01 , experiment name: to verify the stefans law of radiation and to determine stefan s constanta.core componentsi.black body radiator- cavity-type design (emissivity 0.99). - material: nickel-plated copper.- operating range: 50 c 600 c. - aperture diameter: 10 mm 0.1 mm.ii. heating system- pid-controlled furnace (0 600 c). - stability: 0.5 c at 300 c. - power: 500 w (ac 230v).iii. temperature sensor- type k thermocouple or pt100 rtd. - accuracy: 0.5 c at 500 c (nist-traceable).iv. radiation detector- thermopile sensor (spectral range: 0.3 20 m). - responsivity: 10 v/w.- active area: 10 10 mm .v optical path. - water-cooled collimating tube with baffles.- adjustable aperture to define solid angleb.measurement specificationsi. temperature range100 c 500 c (reso
Tender For supply installation and commissioning of physics lab at item wise on turnkey basis at govt new model college jhabua 457661 mp india - supply installation of physics lab equipment on turnkey basis, battery charger 2 to 12 volt., ballistic galvanometer with lamp and scale arrangement, spectrometer prism (crown/flint glass), spectrometer 6" 17 ", 30 sec, opticalbench with riders double bar, opticalbench with riders double bar heavy, inertia table, complete apparatus to verify law of parallel and perpendicular axes for moment of inertia, compund pendulum/bar pendulum, reading telescope, bending of beam apparatus to determine youngs modulus, cantilever to determine youngs modulus, horizontal torisonalpendulamappratus, jaeger apparatlrs to deternrine the surface tension, apparatus to determine the surface tension, apparatus to determine the viscosity of fluid using poiseuiles method, callendor and barnes apparatus to determine the value of mechanical equivalent of heat, measurement of low resistance by carey, potentiometer, lee purpose to determine the hear conductivity of bad conductor of different geometry, apparatus to verify newtons law of cooling, searl apparatus to determine the coefficient of thermal conductivity, sodiurn vapour lamp, transformer for sodium vapour lamp, mercury lamp, transformer of mercury lamp, biprism, complete apparatus to determine the resolving power of a telescope, biquartz are half shade polarimeter, newtons ring apparatus cornplete with travelling microscope power supply and sodium level, electroscope or electrometer, audio fiequency generator, cro dual trace 30 megahertz single tress l0megahertz, i.jse of vibration magnetometer to study a field apparatus, tangent galvanometer, apparatus to study resonance curve for lcr circuit, apparatus for measurement of capacitance and inductance, apparatus to determine the value of plancks constant, complete apparatus to determine e/m using thomson method, complete apparatus to determine e/m by milikons method, apparatus to study the absorption spectra of iodine vapour completes with white light source power supply grating and spectrometer, apparatus to draw bh curve of ferromagnetic material with the help of cro, half wave and full wave rectifier apparatus with built-in power supply, transistor characteristics apparatus with built in power supply and metres, apparatus to study characteristic of tunnel diode, apparatus to study hysteresis curve of transformer core, apparatus to study specific resistance and energy gap of a semiconductor, apparatus to study transistorized regulated power supply, apparatus to study rc coupled amplifier with built-in power supply, zener diode characteristics apparatus with built-in power supply, apparatus to study charging and discharging of a capacitor, complete setup to find the wavelength of sodium light, study of lissajous figure trainer, barton apparatus, digital oscilloscope, adjustable height stands, capillary tube packets of different radii, electrical laboratory kettle with varying voltages, piatinum resistance thermometer, soldering station, desoldering tool, thermocouple apparatus, jfet apparatus to study characteristic curve, hall probe apparatus, plane transmission grating, brewster law apparatus, beam divergence apparatus of helium neon laser, diode laser, holographic diffraction grating, michelson interferometer, logic gates apparatus (or, and not, nand, nor, xor), standard tool box, connecting lead wire for electronic apparatus, flywheel