Get complete information related to latest Optical Breadboard Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Optical Breadboard Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Optical Breadboard Tenders.
Tender For purchase of various apparatus/instruments required for department of chemistry, chaudhary ranbir singh university, jind - stirrer the stirrer should be made up of ceramic coated aluminium alloy top with digital speed and temperature control. the stirring speed should be 50-1500 rpm or better. the stirrer should be operational up to a temperature range of 300oc with an accuracy of 1.0oc and ip 42 protection class. the input power should be 600 w or above. the stirrer should be supplied with hemispheric bowl (100 ml= 1 no; 250 ml= 1 no) to replace oil baths and mantles in order to perform clean and safe analysis with round bottom flasks., electronic balance the electronic balance should have a maximum weighing capacity of 200 g or more with a resolution and repeatability of 0.1 mg, and a response time of 5 sec or better. the system should have automatic internal calibration with touch screen display. the system should have internal database capacity of 2500 or more with multiuser password protection feature. , vacuum pumpthe pump should be operational at a maximum power of 65 w or more with a max. vaccum of 99 mbar or more. the pump should be fitted with vacuum and filter cartridge., hot air oventhe inner chamber should be made of stainless steel and the outer chamber should be m.s powder coated. the maximum capacity of the oven should be 100 ml or more. the operational temperature should be between ambient to 250 oc or more with a temperature accuracy of 1o c. pid based digital temperature control., double distillation unitthe unit should be pyrogen free with a distillation water output capacity of 1.5 l/h. the minimum cooling water requirement should be 1lt/min. auto-power cut facility in case of halted supply of water., circulating oil baththe oil bath should be made up of stainless steel with 4 digit 7 segment led display for temperature and time. the bath should have s.s perforated tray for holding flasks. the bath should have a capacity to accommodate flask of 1l. the working temperature range should be +5 to 240 oc (0.1 oc increment) with a temperature stability of 1oc., water baththe water bath should have a capacity of 20 l within built water level sensor. the bath should be made up of stainless steel and supplied with 8 concentric rings. the bath should have digital temperature control with pt100 sensor. the system should have stirring capability with ptfe magnetic bars. , ph conductivity meter operational between a ph range of -2 to 16.00 with a resolution of 0.01 ph and an accuracy of 0.02 ph. 5 points calibration. the ec range should be in between 0.00 to 29.99 s/cm, uv cabinet operational at two uv wavelengths (254 and 365 nm). the cabinet should also be equipped with one visible light. the external body should be coated with ms powder/epoxy., flame photometerapplication: the flame photometer is used for qualitative and quantitative determination of several cations, especially for metals that are easily excited to higher energy levels at flametemperature. these metals include na+, k+, ca2+, ba2+ and li2+.specification requirementmeasuring range na+: 0 to 99.9 ppm k+:0 to 99.9 ppm ca2+ :0-99.9 ppmli2+: 0 to 99.99 ppmsensitivity na+= 0.1 ppmk+ = 0.1 ppmspecificity less than 0.5% interference when concentrations are equal to test sample concentrationsgas control-adjustable with knobsignition system-auto ignition systemflame failure-auto detectiongas cut off-automaticreproducibility-less than 1% coefficient of variation for 20 consecutive samplesusing 10 ppm na set as maximum standardlinearity-less than 1%display led, 12.5 mm (1/2")fuel supply-high-grade propane/butane mixture regulated at approximately30 psiair supply-6 l/min at 12 psi; oil and moisture freerecorder-output 0.05 to 5 v (switchable)operating manuals, service manuals, other manuals should provide user, technical and maintenance manuals in english language list of equipment and procedures required for local calibration and routine maintenance service and
Tender For corrigendum : design, supply, installation, commissioning, training of various type of equipments for esdm (electronic system design and manufacturing) of msme training centers located at greater noida, bengaluru, puducherry and idemi mumbai on turnkey basis - decade resistance box , ct/pt calibration system , multifunction calibrator , decade capacitance box , ct analyzer , standard resistors , standard weights (el class) , pippete calibration system , low temperature bath (-80 to ambient degree temperature) , frequency counter , energy meter test system (3 position) , precision temperature stabilised resistance standard (high) , decade inductor box , precision temperature stabilised resistance standard (low) , sound level calibrator , digital power analyser , decade resistance box (4 nos.) , process calibrator , hv divider , decade mega ohm box , standard weights (e2 class) , 6 and half dmm , temperature indicator , time interval meter , temperature indicator with compensation , standard weights (f1 class) , semi-micro balance (upto 200 gms) , tachometer calibrator , standard thermocouple (type s) without compensation , sound level analyzer , standard platinum resistance temperature (prt) detector , precision balance (upto 6.1 kg) , thermo-couple calibartion furnace (300 to 1100 degree temperature) , lcr bridge , humidity measurement probe , dry block calibrator (ambient to 600 degree temperature) , anechoic chamber with radiated susceptbility and radiated emission test system , alltitude test chamber , compact emc tester , environmental chamber , digital pressure controller (dead weight pressure tester) , line impedance stablizing network , harmonics/flicker measurement test system , impulse generator , rf shielded chamber , vibration plus environmental chamber , three phase regulated variable power source , humidity generator, relative humidity , bump/shock test system , heat deflection temperature test set , vibration test system , electronic load , conducted rf immunity simulator , rohs testing lab - inductively coupled plasma optical emission spectrometer (icp-oes) , thermal shock chamber , ac dc current source , ultra precision capacitance bridge , esd simulator , horizontaland verticlal flame chamber , rohs testing lab - energy dispersive x-ray fluorescence spectrometer (edxrf) , single phase regulated variable power source , precision energy standard , rohs testing lab - gas chromatograph mass spectrometer (gc-ms) , ingress of water test system - i set , rohs testing lab - ion- chromatograph (ic) , needle flametest chamber , salt spray chamber , dust chamber , digital storage oscilloscope , defibrillator proof test set , thermostat endurance test set , flexing test apparatus , electrical safety tester , winding resistance meter , temperature recorder , radiation meter , tracking test apparatus , gas detector , cord anchorage test set , digital multimeter (handheld/desktop) , glow wire test apparatus