Tender For corrigendum : tender for supply of spares of bently nevada vibration monitoring system f f - probe p n 330105-02-12-05-02-in , cable , 8.0 m , bently , p n -330130-080-02-00 , probe , 330162-01-85-85-xx-xx-94-01-02 , probe p n 330105-02-12-10-02-in , extension cable , p n 330930-060-00-in , probe , p n 330909-0020-10-02-in , velomitor , pn 330525-in , casing vibration probe , p n 330400-02-in , probe , p n 330104-00-11-10-01-in , pressure transducer bn 165855-15 , transmitter , bently , p n-990-04-70-01-00 , earthing module , p n 3500 04-01 , tdi monitor , bntly , p n 3500 22-138607-01 , doul power supply 3500 15-01-01-in , 16 channel relay mod. , p n-3500 33-01-00 , tachometer module 3500 50-01-00-01 , temp monitor p n 3500 60-05-01 , bently temp module p n 3500 65-01-00 , bn 3500 77 cylinder press monitor 143729 , probe , p n 330102-00-08-10-02-in , probe , p n 330702-00-26-10-11-in , pressure transducer bn 165855-14 , accelerometer , p n 330400 01 in , extension p n 330130-040-01-in , ext cable , velomitor ct , cb2w100-32 , intrcnct cbl 30ft bennev , p n 16710-30 , extension cable for velometer , ext cable bently 330730-080-13-05 , extension cable , p n 330130 080 13 in , proximitor p n 330180-50-in , proximitor bently 330780-91-05 , proximitor , 330180-x1-in mod 145004-15 , proximitor , p n 330180-x1-in mod14500-137 , proximitor , p n 330180-x1-in mod14500-75 , vga display module , p n 3500 94-01-00-01 , system display , p n 3500 94m-03-00-in , extension cable , p n 330130-040-03-in , probe , p n 330174-05-10-10-01-in , proximitor , p n 330180-x2-in , proximitor 330180 x1 in mod 143416 14 , proximitor 330180-x1-05 mod 145004-14 , proxpac assembly , 330880-28-00-065-01-02 , proxpac assy p n 330880-28-00-098-01-02 , cpu module , p n 323174-01 , bently nevada , relay card p n 323073-01 , bently nevada , axil prbe bnc , xl330102-04-16-10-02-05 , vibration probe , 330103-00-03-05-02-05 , axial probe , p n-330102-00-20-10-02-05 , pressure monitor , p n 3500 77m-176449-07 , monitor rod positn , pn 3500 72m-176449-09 , velocity monitor , p n 3500 70m-176449-08 , proximitor , p n 330880-28-00-165-01-02 , proxpac assy , p n 330880-28-00-075-01-02 , probe , p n 330102 48 91 10 11 in , vibration probe , p n330905-00-25-05-02-05 , extension cable p n 330930-065-01-00 , proxpac proximitter assy , 178850-05 , vel cable p n-106765-10
Tender For corrigendum : providing drone based monitoring and visualization system services for 2x800 mw koderma thermal power project site koderma jharkhand on monthly rental basis to bhel for a basic period of 48 months
Tender For selection of solar power generators (spgs) on the basis of build own & operate (boo) for design, survey, supply, installation, testing, commissioning, operation & maintenance of grid connected distributed solar power plants for solarization of selected agri feeders at sub-station (ss) level in cesc jurisdiction totally covering ip sets, its associated 11kv line to connect the plant with concerned ss and remote monitoring system (rms) of solar power plants through resco mode, for 25 years under component c-feeder level solarization of pm-kusum scheme
Tender For supply, installation and commissioning of superconducting qubits based quantum computing facility - qubit processing unit (qpu), superconducting quantum processing unit (50 to 100 qubits) with microwave package, travelling wave parametric amplifier (twpa), other cryogenic component sets, fully functional dilution refrigerator, dilution refrigerator for supporting the qubits offered and further scalable to 250 qubits with needed support systems and components, full capacity dr wiring for supporting the qubits offered and further scalable to 250 qubits., control electronics and peripherals, control electronics for supporting the qubits offered and further scalable to 250 qubits with wiring and sub components as required, networking equipment and it infrastructure, high-speed networking infrastructure, quantum-specific networking hardware, secure data storage solutions, networking equipment for iot integration, iot infrastructure and telemetry, integrated telemetry and monitoring systems, iot sensors and devices (cryostat to control electronics), key metrics generation tools, predictive maintenance software and tools, real-time data collection and analysis systems, emi/emc compliance, emi shielding and grounding solutions, emc testing and certification, filtered power supplies, installation and integration services, system installation and setup, training for operation and maintenance, training on planar design and fabrication of qpus, documentation and knowledge transfer, service and support, comprehensive onsite support and maintenance for atleast 3 years, maintenance tools and spare parts, miscellaneous costs, shipping and handling, customs and duties, installation tools and equipment, any other cost
Tender For corrigendum : supply of cctv camera and biometric access systems - night vision eabled ptz camera , prefabricated gi of 20 feet length with stair , heavy duty pvc pipe with bends for safety of cameras wiring , weather proof outdoor boxes for cameras accessories , 4 socket power surge protector for cameras accessories , managed poe switches with 2 sfp , sfp fiber module for network switch , ethernet utp patch cord 05 mtr length , ofc fiber cable unarmored with laying 6 core , ofc fiber cable unarmored with laying 12 core , power cable copper , managed switch with sfp 32 port , giga ethernet switch 5 port , cat 6 ethernet cable , lc to lc fiber patch cable , fiber joint box , hdpe pipe with laying , clamps for hdpe pie hanging , necessaries hardware and accessories for cameras , necessaries hardware and accessories for electrical , giga media converter , online ups system for nvr , ups for cameras backup , power backup battery 12 tubular , power board for inverter connection , 3 pin top for backup connection wiring , outdoor weather proof protection unit for ups , installations of power backup solution , biometric access cont security system with lock , suitable network 42u rack with accessories nvr , network video recorder 16 channel with smart features , 8 tb hard disk for surveillance , commercial grade 43 inch screen for monitoring with hdmi cable 5 meter , suitable networking 6u rack with accessories for nvr at sub sector control rooms , suitable network 4u rack with accessories for cameras
Tender For design, engineering, procurement supply, construction erection, testing, commissioning of solar power plants, associated 33 kv or 11 kv line and remote monitoring system (rms) and comprehensive om for 5 years of grid connected ground mounted sol
Tender For purchase of sports exercise physiology lap equipments - cardiopulmonary exercise testing system system should be compact can be used in laboratory operation and low maintenance costs and easy servicing. system should be state of the art computerized telemetry breath test analyzer for on-line breath by breath measurement of exercise test of respiratory system to measure following parameter: time, ve, bf(rr), hr, feo2, feco2, peo2, peco2, vo2, vco2, ve/vco2(eqco2), ve/vo2(eqo2), rq(rer), vd/vt, vo2/kg, vo2/kg/hr, met, watt(work), hr, ttot, ti, te, ti/te, ti/ttot, pef, pif, br, vet, sum, tv/te, o2 kinetics, oxygen deficit, oxygen debt parameters and indirect calorimetric. wireless hr recording system, indirect cardiac output by wassermann algorithm system should comply ats and ers guide line and it should be ce certified., iso certified system should have automatic ambient conditions measuring system. system should work under temperature range 0 to 50 celsius. system should have facility for automatic calibration of analyzers. volume transducer calibration with precision calibration syringe. system should meet following technical specification flow rate measurement: measuring headpiece should be either through turbine /dvt/ pneumotach and dead space less then 40 ml, it should not be affected by humidity , flow range +/- 18 l/s and accuracy 2% oxygen analyser : should be either electrochemicalcell/paramagnetic and measurement range 0- 100 %,response time t90 100 ms and accuracy +/-0,04 % and- resolution 0,02 %carbon dioxide analyser : should be ndir (infraredabsorption) and measurement range 0 - 10 %,-response time t90 90 ms , accuracy +/- 0,04 %, andresolution 0,02 % software should support latest windows or latest andin corporate customized predicted normal equations.software should be capable of changing graphics displays during real time testing. system should have facility for automatic treadmill or bicycle ergo meter control. should be supplied with software, standard accessories for operation manual carrying case for field use. system should be supplied with latest data acquisition system, deskjet printer and ups. system should comply en iso 13485:2003, en iso 9001:2000, ec certificate93/42/eec, programmable treadmill running machine with user terminal (display &keyboard) stand- alone and remote control via rs232 running surface: l:170 cm (minimum), w: 65 cm (minimum) maximum possible load: 200 kg (440 lbs) speed range: 0-40 km/h elevation: 25% (14 maximum elevation) motorized adjustment, reverse belt rotation. motor system 3.3 kw, single phase ac motor, maintenance free and brushless power transmission: frequency inverter, poly v- belt, very quiet operation safety system: emergency-off safety stop switch (safety lanyard with actuator, pull cord and clip); potential equalization bolt; transformer for potential-isolation from the mains ambient condition: temperature: +10to +40 degrees c, humidity 30 to 70% display (resolution): lcd display heartrate monitoring: wireless transmitter; the treadmill should be able to interface with well-known compatible metabolic gas analyzer as per standard and custom exercise protocols different programs safety harness-1. indispensable accessory for stress testing, accident prevention and for the general safety of athletes.2. safety arch with different heights and widths to fit all running machines.3. an emergency stop at the crossbar of the safety arch allows automatic stop of the running belt in the moment a fall occurs.4. the harness and chest belt (available in 5 sizes: xxs, s, m, l, xl) secure the subject and prevents falling over to the front.5. chest belt straps do not pinch or restrict the athlete", programmable ergometer functional design and excellent stability, load up to 160kg. easy to use saddle, handle bar and pedals speed independent and dependent power control handle bars are easy to change to suit different tests, rotatable by 360 degrees. mechanical/motor-assisted seat a
Tender For purchase of recovery and rejuvenation lab. - infrared sauna tower irradiance: 55-110 mw/cm2, providing therapeutic benefits rated power: 100-240v ac, 2 amp, 50-60hz, suitable for standard electrical outlets wattage: 350w, combining red light and near-infrared therapy wavelength: 650nm (red light) and 850nm (near-infrared), promoting healing and relaxation led arrays: 70 red light leds (650nm) and 70 near-infrared leds (850nm), ensuring optimal coverage variable optics: 7 60-degree optics for maximum impact and quicker results. emf emissions: no detectable emf emissions at 10-15cm, prioritizing user safety. infrared sauna units with below mentioned features to be preferred- heaters: full spectrum heaters (400w each) or carbon fiber heaters (up to 2160w total power) temperature control: digital temperature and time control for customizable sessions materials: canadian hemlock wood or western red cedar, known for durability and hypoallergenic properties additional features: bluetooth connectivity, chromotherapy lights, and built-in stereo speakers for an enhanced experience. energy efficiency: reduced electricity consumption for cost-effective use temperature range: operating temperatures between 115 f and 140 f for comfortable sessions safety features: person-specific designs and low emf emissions for safe use, cryotherapy chamberwhole body cryo therapy chamber that runs completely on electricity without need of liquidnitrogen low temperatures within the range: -130 to -140 degree celsius. multiple treatment options electric mechanical lift system ensures user s head is outside the chamber to prevent exposure to cryogenic temperatures. real-time skin temperature monitoring using ir tech sensors ensuring safe and controlledcooling. smart software that manages the treatment processes throughout each session. simple quick plug-and-play set up without requiring specialized ventilation. large uhd touchscreen for easy operation and control. at least 3 media monitors for displaying media content. hifi speakers for audio entertainment and ambient audio. work on normal indian 220v at 16a or less, whole-body pneumatic lymphatic drainage machine:key features- multi-chamber design: multiple chambers that inflate and deflate in sequence to mimic manual lymphatic drainage- adjustable pressure: adjustable pressure settings to accommodate different patient needs and comfort levels- programmable treatment: programmable treatment protocols for customized therapy sessions- user-friendly interface: intuitive interface for easy operation and programming- input voltage: ac110v/220v- power consumption: less than 400w- screen: 8-inch wide color touch screen- air pressure: 20-360 mmhg (max pressure 37.5kpa)- cooling device output temperature: 5 to -16 c- output vacuum pressure: 0-110kpa- default time: 0-60 minutes- fuse size: f3al250v- ambient temperature: 5 c to 42 c- number of air bags: 24 bags or 16 pairs atleast - treatment modes: 4 modes atleast - intensity levels: 3 levels- package size: 62x42x31cm approx - gross weight: 15 kg approxsafety features- automatic pressure adjustment: automatic pressure adjustment to prevent excessive pressure and ensure patient comfort- emergency stop: emergency stop feature to quickly deflate chambers in case of discomfort or distress- patient monitoring: optional patient monitoring capabilities to track vital signs and treatment responseadditional features- multiple treatment modes: multiple treatment modes for different conditions, such as lymphedema, edema, and post-surgical swelling- data logging: optional data logging capabilities to track treatment parameters and patient progress- portability: optional portable design for increased flexibility and convenience.certifications: ce or fda clearance, percussion massager (gun massager)key features- percussive action: a percussive action that provides rapid and repetitive strokes to muscles and tissues- adjustable speed: adjustable speed settings to customize the mass
Tender For selection of solar power generator (spg) on the basis of build own & operate (boo) for design, survey, supply, installation, testing, commissioning, operation, repair & maintenance of grid connected 9.6 mwp (dc) solar power plant in chittapur town chittapur taluk, kalaburagi district and its associated 11kv line to connect the plant with 110/33/11kv chittapur ss and remote monitoring system (rms) of solar power plants under group captive mode through ppp model to meet the energy demand for water supply and street light installations in chittapur constituency
Tender For tender for supply of remote monitoring and protection panel for 4 da sets rmpp , maint free battery , backup power supply sub system , signal conditioning module , logic controller module for me lcp , logic controller module for mer , logic controller module for da lcp , temp signal conditioning module for thermo couple , light bar pcbs for shaft rpm , speed control pcb , main control pcb , temp measurement pcb , over load relay 3-5a , rpm indicator 72 sq mm 4-20 ma with dial , pressure transmitter 4-20ma dc 0-6 bar , rotary switch , battery 12v