Tender For ece lab items dept use - eliminator transformer (step-down) kitinput - 220v - 240v ac, 50 hz, output-2v to 12v dc, 0-2 a ripple: 5mv, strain gauge trainer kitmetal foil strain gauge mounted on beam/cantilever strain measurement under applied load wheatstone bridge arrangementsignal conditioning and amplification circuitinstrumentation amplifiers, 3 digit display of strain / output voltage zero and gain adjustment controlsprovision for applying calibrated loads regulated power supply, 230 v ac, 50 hz table-top trainer with labeled paneltest points to measure the signalsbuilt in power supplies and wooden closed cabinet supplied with patch cords and experiment manual, temperature measurement kitsensors: rtd (pt-100), thermocouple (fe-k/j-type), and/or thermistor (ntc).display: 3 digit led/lcd digital display (typically 200mv fsd). temperature source: portable water kettle or heater block.signal conditioning: on-board circuitry for amplification, linearization, and cold junction compensation.test points: multiple 2mm/4mm banana sockets for monitoring input/output signals.power supply: 230v ac, 50hz, single-phase.accessories: includes a glass thermometer, ntc thermistor probe 10k, k-type thermocouple probe, patch cords, and instruction manual., sim reader trainer kitsim compatibility supports 2g 3g 4g lte sim cards,sim reader mode: reading writing gsm sim card data, imsi, ki codes, phonebook interface usb 2.0 or rs 232 serial port for pc communication.clock frequencies: selectable frequencies 3.579 mhz, 7.159 mhz, 14.318 mhz for sim card operation.power supply: onboard smps 12v 2a or 5v dc with overload protection. hardware components:6-pin or 8 pin sim card socket.led indicators for power, sim reset, and data activity.optional lcd 128x64 and keypad 20 keys for standalone operation. software tools support for at commands gsm etsi 07.0707.05, sim manager utilities, and data logger functionality. common trainer kit featuresfault simulation ability to create faults e.g., sim not detected, vcc failure for troubleshooting.test points: multiple test points e.g., 55 nos for observing signals sim rst, clk, i o via oscilloscope.construction tested glass epoxy pcb, often housed in a study educational case., dual output regulated dc variable power supplydual output regulated power supply- input voltage: 230v/50hzac- output voltage: (0 30v)dc- output current: (0 2a)dc- protection circuit: over voltage and over current protection, short-circuit protection- high efficiency: greater than 85%- low ripple and noise: less than 50 mv, lvdt sensor trainer kitac mains power supply : 230v 10%, 50hzfixed regulated dc power supply : +5v, 12v 500matransducer : lvdtlvdt displacement : 20mm (40mm total)displacement scale : linear 20mmdisplacement display (mm) : red color 3 digit led displayexcitation frequency : 4khzexcitation voltage : ac variable 5v, dc digital voltmeter - 3 digit led/lcd display, measurement range: 0 20 v dc, accuracy: class 0.5( 0.5 % full-scale), dc ammeter digital - 3 digit led/lcd display, measurement range: 0 5 a dc, accuracy: class 0.5 ( 0.5 % full-scale)
Tender For purchase of equipments for ece department - function generator frequency range: 0.1 hz to 5 mhz display: 4 to 6 digit led display output waveforms: sine, triangle, square, pulse, ramp . amplitude: 0 20 vpp. rise time: 100 ns. distortion: 1% within specified frequency range power supply: 230 v ac 10%, 50 60 hz. output amplifier protection: short-circuit and 15 v, strain gauge trainer kit ac mains power supply: 230 v 10%, 50 hz metal foil strain gauge mounted on beam/cantilever. strain measurement under applied load. wheatstone bridge arrangement. signal conditioning and amplification circuit. instrumentation amplifiers with 3 digit display for strain / output voltage. zero and gain adjustment controls. provision for applying calibrated loads. table-top trainer with labelled panel. test points for signal measurement. built-in dc power supplies and wooden closed cabinet. supplied with patch cords and user manual., temperature measurement kit sensors: rtd (pt-100), thermocouple (fe-k/j-type), and/or thermistor (ntc). display: 3 digit led/lcd digital display (typically 200 mv fsd). temperature source: portable water kettle or heater block. signal conditioning: on-board circuitry for amplification, linearization, and cold junction compensation. test points: multiple 2 mm / 4 mm banana sockets for monitoring input/output signals. power supply: 230 v ac, 50 hz, single-phase. accessories: glass thermometer, 10 k ntc thermistor probe, k-type thermocouple probe, patch cords and user manual., cathode ray oscilloscope bandwidth: dc to 30 mhz (-3 db) - sensitivity: 1 mv/div to 5 v/div - display modes: ch1, ch2, dual (chop/alt), add, sub - timebase: 0.2 s/div to 0.5 s/div (essential for slow bio-signals) - magnification: x 10 sweep magnifier - triggering: alt triggering, auto, norm, - tv-v/h with source selection (ch1, ch2, line, ext). - input impedance: 1 mohm || 25pf - included accessories: two 60 mhz passive probes, power cord, and user manual
Tender For supply of gps based oscillationmonitoringsystem as per rdso specification no.tm/sm/420 (version 1.2 of 2023) or latest if any) with warranty period of 2 years and annual maintenance contract period of 3 years total 5 years (details specification enclosed) specification attached. [ warranty period: 30 months after the date of delivery ] ]
Tender For corrigendum : supply of mixed signal oscilloscope , hydrogen electrolyser load , thermal image camera , programmable high voltage dc power supply , digital probe
Tender For supply of gps based oscillationmonitoringsystem [gps based oscillationmonitoringsystem (gps-oms) as per rdso specification no. tm/sm/420 dated 15.02.21 or latest up to date of tender opening with post warranty annual maintenance contract for five years. ]
Tender For supply of dc power supply , digital storage oscilloscope , igbt stack , voltage probe , current probe , bnc connectors , voltage sensors , current sensors , digital controller , dc loads , personal computer system