Get complete information related to latest Outdoor Cooler Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Outdoor Cooler Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Outdoor Cooler Tenders.
Tender For auction sale of (1) heavy duty air compressor (excluding motor) (2) light duty air compressor (excluding motor) (3) mould (mould for making plastic tools) (4) injection moulding machine (scrap condition with electric panel board-4 nos.) (5) grinding machine (excluding motor) (9) air cooler no.-3 (7) earth scooter (in broken condition no. gj-1 eg 6546) (8) m.s. cupboard and small rack 1 no. (9) prepared plastic container bags (10) frp cooling tower no.-1 (11) trolley with wheel no.-1 total items-11 (eleven)
Tender For supply of supplying installation testing and commissioning of lab equipments c c - working model of cooling system , working model of transmission system , working model of fuel system , working model of electrical system , cut section model of petrol engine 4 cylinder , cut section model of diesel engine 4 cylinder , cut section model of diesel engine 6 cylinder , cut section model of rear axle assembly , front axle with pull and push rod and tie assembly , gear box assembly , steering box assembly , brake chamber , e-1 brake valve , air filter , clutch cover assembly , clutch disc , gear box gears , top gear shaft , main shaft , counter gear , axle shaft , crown wheel with pinion , starter motor , alternator , msm and psl safety routines , ipde principle , stoping distance , following distance , curve handling , traffic sign boards , over head projector , slide projector , tv and vcr vcd , multimedia projector , magnetic board , air compressor , ponture kit with tyre lever , wheel brace , jack and tyre pressure gauge , trolley jack , grease gun , spanners a set each no. fix spanners, box spanners, pliers, screw drivers, screw spanners and hammer , battery charger , vision drum placed 20 feet 6 mts. from the person , trial set with frame , ishihara chart for color vision testing , near vision chart , weighing machine , height meter for measuring height
Tender For overhauling repairs to water turbine driven horizontal pumping unit at achoora gurez of misd hajin. - overhauling/major mechanical repairs/replacements of damaged non-functional mini water driven turbine (damaged by heavy snow slide) coupled with 03 cusec horizontal pumping unit. the job comprises of following works: pump sidei. engaging of labours in the machine drive chamber by way of moving of boulders and other trash till the machine chamber be cleaned and washed., ii. temporary oiling the turbine and pumping unit on machine chamber side till the the mechanism of machinery is free from rust and dust, then decoupling the pumping unit from the turbine coupling and genset from belting. using skilled labour and other tools and tackles., iii. dismantling of 8 x8 horizontal pumping unit from its existing pump foundation to machine floor smoothly without any hammer stroke using skilled job knowing personnel., iv. dismantling of the pumping unit parts at machine floor,removing of defective rotating kit assembly from the pump body using proper tools to be arranged by firm., v. shifting of the dismantled kit assembly with the allied accessories and defective chain pulley block to road side upto the lead of 150 m by head loading and then loading the rotating kit assembly in private load carrier to be arranged by the firm and shifting to workshop for conducting necessary repairs., vi. complete servicing of rotating kit cum bearing housing at workshop using diesel oil till the whole bearing assembly and rotating parts are washed and cleaned and free from rust and dirt. the job includes dismantling of bearing housing and removing of defective parts like damaged shaft, broken bearings and other items smoothly. the job includes removing of broken bolts from the bearing housing, re-tapping the damaged holes and providing and fitting of new holes., vii. repairs to impeller shaft of the pump by way of rebuilding the damaged portion using arc welding and then machining, polishing, threading completely till the size of the shaft is brought to required specifications. the job further includes providing and fitting of check nut as per sample., viii. manufacturing/providing and fitting of gm bush to suction part and gm cooling ring, gm gland with bolts. the job includes casting, machining, finishing to proper dimensions., ix. providing and fitting of high pressure gasket on suction side and delivery side., providing and fitting of ht bolts of assorted size, xi. rebuilding the wearing ring seats of suction and coupling end plates using ci welding electrodes. the job includes machining and finishing to proper dimensions., xii. repairs to defaced/ damaged impeller shoulder ring seats using ci welding electrodes. . the job includes machining and finishing to proper dimensions., providing and fitting of taper roller bearing on coupling side and gland side. the job includes greasing of bearing xiv. 32315, xv. 32314, xvi. assembling of bearing housing with rotating kit at workshop to check the rotating kit assembly is free from any obstacles and loading and shifting to site in private load carrier to be arranged by the firm including haltage and retun back of workers, turbine side:- repairs to turbine side by way of:complete cleaning and washing of turbine chamber by way of removing of boulders and other trash from the turbine by engaging of labours.complete servicing/ washing/oiling of turbine assembly in turbine chamber till the assembly of turbine and guide vanes are free from the rust and dust and then complete oil washing the guide vanes, guide hinges and outer body of turbineproviding and fitting if turbine shaft gm bush bearingtesting of turbine assembly on no-load decoupled from pump assembly by way of charging of turbine chamber to check the vibration, sound, rpm, setting of turbine guide vanes, hinges to ensure smooth functionre-installation of pumping unit by way of fitting of rotating kit assemblycomplete painting by black japan to entire pu
Tender For providing of design installation and maintenance of educational lab/centre - science lab; mechanical and electrical lab; buyer - impact testing machine, vernier caliper, outside micrometer, inside micrometer, vernier height gauge and depth gauge, slip gauge block set, sinebar, surface plate, optical pyrometer, thermocouple, bevel protractor, dial indicator with stand, digital vernier caliper, venturimeter apparatus, bemoulli's apparatus, pipe friction apparatus, orifice & mouthpiece apparatus, model of simple carburett or, model of compund carbur rettor, evaporative condenser model, cooling system of ic engine model, single phase, transformer panel for dc and sc test, expenmental board for, study of p-n junction, diode characteristics, experimental board to study transistor, characteristicss
Tender For tender for supply of supply and installation commissiong d d -supply installation testing and commissioning of 2tr 24000 btu per hour minimum bee 3 star rated confirming to is 1392 part 2 2018 inverter type cassette split ceiling mount air conditioner having wireless remote controller led display for indoor unit motorized vertical horizontal swing controls air filters uto restart with memory features inbuilt drain pump rotary scroll hermetically sealed compressor and initial charge of eco friendly refrigerant condensor and evaporator coils of copper material suitable for operation on 230v 10 single phase 50hz ac power supply the indoor unit shall be suspended from the ceiling using threaded rods including clamps bolts nuts etc and the outdoor unit shall be mounted on floor complete as required , supply and laying of soft drawn copper refrigerant pipe of suitable size for 2tr air conditioners for interconnection of suction and liquid lines between indoor and outdoor unit with tubular thermal foam insulation including necessary brazing jointing etc as required for cassette split air conditioner as required for item no 1 , supply laying of 4c x 25 sqmm frls pvc insulated 1 1 kv grade pvc sheathed multistrand flexible copper cable confirming to is 7098 pt 1 1988 along with the refrigerant lines for connecting indoor and outdoor units , supply and fixing of 25 mm dia minimum thickness of 1 2mm pvc drain pipe along with accessories and necessary clamps with an u trap at the end as required , supply and fixing of 75mm dia minimum 18mm thickness pvc covering pipe using necessary bend colloc clamps threded rod supports accessories etc for laying copper refrigernt line electrical cable and drain line as required. , supply and installation of floor mounted powder coated ms 25 x 25x5mm l angle frame including clamps bolts nuts vibrating dampers as required , drilling of hole using core cutting machine of size up to 100 mm dia in concrete stone wall ceiling for laying refrigerant lines etc and finishing the same with cement mortar after laying , dismantling shifting of old 2tr cassette split air conditioner having indoor and outdoor units associated refrigerant pipes electrical wires and drain pipes including pump down of refrigerant. , making of necessary alteration of existing gypsum false ceiling for installation of cassette air conditioner indoor units including necessary aluminium channel support gypsum board necessary accessories including painting to match for the existing false ceiling , supply installation testing and commissioning of 2tr 24000 btu per hour and iseer value five star rated and compliance with is 1391 part 2 2018 wall mounted inverter type hi wall split cooling inverter air conditioner having wireless remote controller with led display hermetically sealed scroll rotary compressor and eco friendly refrigerant initial charge of refrigerant condensor and evaporator coils of copper material air filter with auto swing auto restart features suitable for operation on 230v single phase 50hz ac power supply the indoor unit shall be fixed rigidly on wall using necessary frame the outdoor unit shall be mounted on floor laying and interconnection of standard length copper refrigerant piping as supplied by the oem between indoor and outdoor units complete in all respects as required necessary drilling of hole and finishing the same to match for the surrounding as required. , supply and laying of beyond the standard length supplied by the oem copper refrigerant pipe of size suitable for 2tr air conditioners for interconnection of suction and liquid lines between indoor and outdoor unit with tubular thermal foam insulation for hi wall split air conditioner as required for item no 1 , supply laying of 4c x 25 sqmm frls pvc insulated 1 1 kv grade pvc sheathed multistrand flexible copper cable confirming to is 7098 pt 1 1988 along with the refrigerant lines for connecting indoor and outdoor units , supply and fixing of 75mm dia minim
Tender For provn of furniture items for fd tech shelter - the bidder is required to quote itemwise price for the various scope of work listed in the boq document individually and overall rate of all the items would be taken for deriving the l1 bidder., ms steel storage wall racks of size 900 x 350 x2100 mm, sample as approved by acceptiong officer, tech specifications given in appx a ., double sided ms steel storage centre racks of size 900 x 900 x 1500 mm, sample as approved by acception officer, tech specifications given in appx a , ms steel storage heavy duty wall racks of size 900 x 350 x 1500 mm, sample as approved by acceptiong officer, tech specifications given in appx a ., ms steel storage racks of size 900 x 350 x 1500 mm(05 shelves), sample as approved by accepting officer. tech specifications given in appx a ., bottled water dispenser, bottled water dispenser body made of abs plastic and tank made of food grade stainless steel. capacitly of cooling and hot water shall be of 3 liters and 5 liters respectively with 3 temperature taps like hot, plain and cold. heavy duty bottle piercer with bottle holder shall be provided to hold the water bottle of capacity 20 ltrs. bottom of the body shall consist of a refrigerator of 14 capacity. make : blue star/usha. tech specifications given in appx a ., plastic baskets of size 350 x 400 mm, make : nilkamal/cello. tech specifications given in appx a ., desk with glass transaction counter and 2 sets of drawers, colour-american dark cherry, material - wooder, size w1200 x d1000 x h1200 mm, tech specification given in appx a ., stainless steel storage rack/bin size w1200 x h1800 x d600. tech specifications in appx a ., air curtain with sensor & remote operating type, cooling power 700 w, 1500 x 230 mm, minimum 3 star bee rating, noise (db)>52, 220v/50hz., self weighing machine of capacity - 30 kg with barcode printing, isi marked., hdpe durable tables and 04 x chairs for each table. size of table 600 x 600 x 550 mm height and size of chair 580 x 600 x 760 mm height. sample as approved, engineered wood height adjustable 800 mm to 120 mm standing table wooden top size 600 x 450 mm. sample as approved by accepting, officer.
Tender For supply, installation, testing & commissioning of 2 ton tower air conditioner , energy efficient 5 star rated, cooling power->= 3200 watts, power supply- 230 v ac 50 hz, noise level: <=43 db, with remote control and with all required accessories. make:- voltas or daikin or lg or blue star or lloyd or mitsubishi or similar. warranty: 1 year on machine, 5 years on compressor. -(warranty period : 60 months from the date of supply)
Tender For supply and installation testing & commissioning of tower air conditioner unit nominal cooling capacity 04 ton/12000 kcal/ per hr. or 48000 btu/hr. floor standing type split air conditioner, supply voltage 3 phase 415 volt +/- 5% ac, 50 hz. (technology of ac, fixed speed cooling only) coil material copper, eco friendly refrigerant, refrigerant 410 (a) or r-32 with outdoor and indoor unit, coil material (evaporator) 100 percent copper, coil material (condenser) 100 percent copper, conforming to is: 1391 with wireless remote. acceptable make- voltas, daikin, hitachi,lg, mitsubishi,bluestar, carrier, whirlphool,o general. warranty 2 years for compressor and 1 year for ac machine. suitable accessories required: 1)suction copper pipe with insulation puff - 100 mtr 2)discharge copper pipe with insulation puff- 100 mtr 3)supply of copper flexible cable 4 core*4 sq mm isi mark, voltage upto 1.1 kv ,copper conductor ,multicore flexible cables- 300 mtr. 4) m.s stand suitable for outdoor unit- 6 set.