Web Analytics Made Easy - StatCounter

Oxide Scale Measurement Machine Tenders

Get complete information related to latest Oxide Scale Measurement Machine Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Oxide Scale Measurement Machine Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Oxide Scale Measurement Machine Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

CTN :41012636 Due date: 23 Jul, 202523 Jul, 2025 NA
Tender For supply of vernier callipers , screw gauge , travelling microscope , sextant , helical spring , slotted weights with hanger , stop watch , metal wire , flywheel , capillary tube , beaker 500ml , spherometer , thermometer , spirit level , optical lever method kit , maxwell needle kit , searle method kit , bar pendulum , kater pendulum , digital multimeter , dc voltmeter 0-25volts , dc voltmeter 0-10volts , dc multimeter 0-25ma , dc ammeter 0-3amp , resistors known values , connecting wires , breadboard or circuit board , crocodile clips or banana plugs , soldering iron , ic 4017 , leds , connecting wires or jumper wires , dc power supply , dual power supply , cathode ray oscilloscope , ballistic galvanometer , de sauty bridge , measurement of field strength b and its variation in a solenoid , series rc circuit , series lcr circuit , parallel lcr circuit , carey foster bridge , connecting probes red and black wires , resistors , battery eliminator , potentiometer , function generator 10mhz , he- ne laser , diffraction grating with 1500 lpi , grating holder , hydrogen discharge tube with power supply , meter scale , optical bench , lens holders , convex lenses of different apertures , meldey experiment , set of weights , ac power supply , connecting wires or bnc cables , spectrometer , prism , sodium bulb with transformer for spectrometer , mercury lamp with transformer , fresnel biprism , to study lissajous figures , newton rings , callender and barnes constant flow , black body radiation , searle apparatus , platinum resistance thermometer , thermocouple with temperature , vi characteristics of solar cell trainer board , material of a wire searles pattern , quinck tube method , guoy method , solenoid and determine energy loss from hysteresis , opamp , compass needle , experiment set up thomson method , geiger-muller counter , digital balance 2 digit , digital balance 3 digit , digital ph meter , digital colorimeter , centrifuge machine 6000 rpm , water distillation plant , test tube , laminar air flow , magnetic stirrer with hot plate , muffle furnace , heating mental with regulator 500 ml , melting point apparatus , uv spectrophotometer , hot air oven , polarimeter , refrigerator, frost free, double door , beaker 100ml , beaker 250ml , conical flask 250ml , conical flask 500ml , chemical thermometer , round bottom flask 100 ml , round bottom flask 250 ml , measuring cylinder 25ml , measuring cylinder 50ml , measuring cylinder 100ml , filter paper , burette 50ml , pipette 25ml , pipette 50ml , bloating paper , test tube holder , wire gauze , electrical conductivity meter , buchner funnel , flask shaker , desiccators , ph paper , capillary tube , viscometer , reagent bottle 250ml , copper water bath , bunsen burner , soxhlet apparatus, borosilicate , vortex shaker , orbital shaker , compound microscope , binocular microscope , autoclave 50 ltr , incubator , deep freezer 300 ltr , ph meter , digital colony counter , uv spectrophotometer with quartz cuvette , bod incubator , vortex shaker for test tube , water bath, digital , inoculating loop , spirit lamp , vernier calipers , ocular micrometer , stage micrometer , haemocytometer , soil thermometer , anemometer , lux meter , dissolve oxygen meter , water distillation plant with automatic power cut , trinocular microscope , centrifuge rotor , microtome machine , slide

CTN :40978246 Due date: 28 Jul, 202528 Jul, 2025 NA
Tender For supply of consumables for laboratory : - bottom connector for ea 18x2x1 mm , valco bulkhead connector , bush ceramic id 2.1 lg 3 , capillary fused silica 0.18_0.27 , ceramics column , spacer ring , spacer 24.8 x 21 x 1 ceramic , spacer 24 8 x 21 x 2 quartz , spacer 24.8 x 21 x 4 quartz , spacer tube od5x3.2x1.5l , capillary.fused silica id 0.32 , gasket fibre 8 x 5 , slit-0.2 source tantal , compressed air service unit , measurement needle gas bench , membrane complete , microspatula , nafion tubing f. gas dryer , pressure spring , connector m5 for tube , seal type 292.3406 , set dichtungsringe

State Government

CTN :40841890 Due date: 18 Jul, 202518 Jul, 2025 NA
Tender For supply and installation of laboratory equipment experimental setup for fyimp ug practical classes at the department of physics, gauhati university - laboratory equipments/experiment set ups, experiment name: to verify the law of malus for plane polarised lighttechnical specifcations:i. light source: - led: 532 nm or 635 nm ( 2 nm stability), 1 5 mw adjustable output. - unpolarized (extinction ratio >500:1). - collimated beam (divergence 0.5 mrad); qty-1ii. polarizers- glan-thompson or polymer film. - extinction ratio 10 :1 @ operating wavelength.- mounted in 50 mm rotation holders.; qty-2iii. rotation stage- motorized analyzer rotation (0.05 resolution). - accuracy: 0.1 . - range: 0 360 (continuous).; qty-1iv. photodetector- silicon photodiode (400 1100 nm). - linearity: r 0.999 (0.1 w 5 mw).- digital readout: 0.1 w resolution.; qty-1v. optical bench-- anodized rail ( 60 cm) with kinematic mounts. - vibration-damping feet.; qty-1, experiment name: to determine thespecific rotation of sugar solution using polarimetertechnical requirementsa.core instrumenti. light source- - sodium d-line (589.3 nm) or tunable led ( 2 nm stability). - output stability: 0.2% drift/hour.ii. polarizer/analyzer- glan-thompson prisms or high-grade polymer film. - extinction ratio 10,000:1 at 589 nm.iii. rotation stage- motorized with 0.001 resolution.- accuracy: 0.005 .- range: -90 to +90 .iv. sample cell-- borosilicate glass tubes with precision ground ends. - path lengths: 0.5 dm, 1.0 dm, 2.0 dm ( 0.01 dm tolerance). - temperature-controlled jacket (5 50 c 0.1 c).v. detector- photomultiplier tube (pmt) or low-noise photodiode. - linearity: r 0.999 over 0.1 w 5 mw rangevi. enclosure- light-tight with vibration damping. - internal black anodized surfaces.b.measurement specificationsi. specific rotation: range: -180 to +180 resolution: 0.001 accuracy: 0.01 ii. concentration-range: 0.01 0.5 g/ml (sucrose in water) detection limit: 0.001 g/mliii. temperature control-stability: 0.1 c at 20 c (standard condition), experiment name: to determine the wavelength and velocity of ultrasonic waves in a liquid (kerosene oil, xylene, etc.) by studying the diffraction through ultrasonic gratinga.core componentsi. ultrasonic generator- - frequency range: 1 10 mhz ( 0.1% stability). - adjustable output: 0 50 w. - digital display (resolution: 0.01 mhz).ii. transducer- piezoelectric (pzt) crystal, resonant at 2 5 mhz. - liquid-coupled design for efficient energy transferiii. liquid cell- optical glass (low thermal expansion). - dimensions: 100 50 50 mm (l w h). - sealed with quartz windows.iv. light source- he-ne laser (632.8 nm, 2 mw) or sodium lamp (589.3 nm). - beam collimation: 0.5 mrad divergence.v. optical system- adjustable slit (10 500 m). - collimating lens (f = 150 mm, 50 mm). - precision rotation stage for detector (0.01 resolution).vi. detection system- photodiode/pmt detector with linear response (400 800 nm). - traveling microscope (0.01 mm resolution) or ccd camera ( 5 mp).b.measurement specificationsi.wavelength ( )range: 0.1 2 mm, resolution: 0.001 mm, accuracy: 1%ii. velocity (v)range: 800 2000 m/s (liquids) resolution: 1 m/s accuracy: 2%iii. diffraction angles- measurement range: 30 resolution: 0.01 , experiment name: to verify the stefans law of radiation and to determine stefan s constanta.core componentsi.black body radiator- cavity-type design (emissivity 0.99). - material: nickel-plated copper.- operating range: 50 c 600 c. - aperture diameter: 10 mm 0.1 mm.ii. heating system- pid-controlled furnace (0 600 c). - stability: 0.5 c at 300 c. - power: 500 w (ac 230v).iii. temperature sensor- type k thermocouple or pt100 rtd. - accuracy: 0.5 c at 500 c (nist-traceable).iv. radiation detector- thermopile sensor (spectral range: 0.3 20 m). - responsivity: 10 v/w.- active area: 10 10 mm .v optical path. - water-cooled collimating tube with baffles.- adjustable aperture to define solid angleb.measurement specificationsi. temperature range100 c 500 c (reso

CTN :40644384 Due date: 17 Jul, 202517 Jul, 2025 NA
Tender For supply of amplitude modulation transmitter kit , amplitude demodulation receiver kit , frequency modulation transmitter kit , frequency demodulation receiver kit , noise power spectral density measurement kit , fourier synthesis kit , filter or noise and audio amplifier kit , communication training system , electronic work bench , analog communication training system with 9khz to 3.6 ghz spectrum analyzer
 Loading, Please wait...

Connect us via What's Up