Tender For purchase of equipments - purchase of equipment:chromatographic workstation with capillary injector, packed injector, and auto-sampler should be quoted. chromatography workstation instruments should be built with self-diagnostic features and active-time management tools for better productivity, general features of chromatography workstation: column oven can accommodate two columns with maximum temperature range up to 400 c with set point resolution of 0.1 c. it should support 20 ramps & maximum temperature ramp rates of 100 c /min. cool down of oven from 400 c to 50 c in less than 5 min. fully automated with electronic pneumatic control afc / ppc / epc (digital control) for injector gas afc/epc/ppc should provide optimum performance with all types of capillary columns. system should have the capability to install a minimum of three injection and four detector ports. capable of detecting h and o across 0.01% 100% ranges (i.e., both trace in a matrix and bulk near-pure streams) column oven: operational temperature range: ambient +10 to 400 c overheat protection: programmable up to 420 c injector port: split/spitless injector 1 no packed injector 1 no, maximum temperature: 400 c, pressure setting range 0 100 psi with control setpoint of 0.01psi for specified pressure range., carrier gas flow control should have constant flow, constant pressure modes and constant linear velocity. auto injector: automatic sample injector up to 15 vials 2 ml vial with crimp set 100 nos, detector: flame ionisation detector (fid) 1 no, minimum detectable quantity: 3 pgc/s or more liner dynamic range: 1 107, maximum acquisition rate: 4 ms (250hz), thermal conductivity detector, sensitivity: >40000 mv maximum acquisition rate: 4 ms, maximum operating temp: 400 cgas cylinders & fittings, gas sampling: zero air, h2, n2 and helium gas cylinder with 2-stage regulators, each 1 no. four-stage gas purification panel and gas tubing. quote a suitable gas sample injector apparatus for the analysis of co2 gas, gas standards and a suitable packed column quote a 6-port gas sampling valve suitable for both manual (through syringe) and auto injection (online) quote sample line, sample loop, heated lines, filters, safety hydrogen purging, and flow control of gas. calibration gasses: suitable gas standards such as ar, he, h2, o2, co and ch4 should be providedpc and ups: pc i5 (or higher), 8gb ram, 1tb hdd, 22-inch led monitor (or higher), ssd: 512 gb, windows 10 os (or higher), wired keyboard and mouse. laser printer b/w, online ups sine wave capacity of 5 kva with battery power backup of 1 hour should be provided by the supplier general terms and conditions:warranty: 3 years manufacturer s warranty certificate. vendor should be an authorised provider of sophisticated high-precision chromatograph workstation systems for the past 15 years or more with: a proven track record in multiple countries and national institutes standard quality certifications such (iso 9001) 5+ past installations of similar systems in india. compliance statement should be enclosed with the quotation. the installation should be done at free of cost. hands-on training for 1 day for two trainees (faculty and scholars) must be provided on operation, maintenance and troubleshooting to two to two-three persons at the site of installation. if required, hands-on training must also be given to our faculty/scholars at a later stage, without any financial commitment to university. the technical details of the quoted instrument must be available on the official website of the principal supplier. the vendor should provide the list of end-users (recent) with contact details. the vendor must submit the latest reference letters from their previous users. trained service engineers in india (with suitable certificates) for the quoted model must be readily available to resolve the technical problems. a list of recent scientific publications in reputed journals from the user institutions where the quoted mode
Tender For corrigendum : e-tender for procurement o surgical instrument for different health institution - name of the item with specification, adrenalectomy gall badder forceps,265mm, adson periosteal elevators chisel -edge width 8mm,165mm(98 litres), adson periosteal elevators sharp width-5mm,165mm, air rotor hand piece, atraumatic fixation and dissecting forceps 5mmx220mm, atraumatic fixation and dissecting forceps 5mmx310mm, atraumatic fixation and dissecting forceps 5mmx420mm, allis atraumatic tissue grasping forceps straight 5mmx310mm, allis tissue grasping forceps 150mm, allis tissue grasping forceps 180mm, allis tissue grasping forceps atraumatic jaw,200mmchamber, allis tissue grasping forceps atraumatic jaw,150mm, allis tissue grasping forceps atraumatic jaw,180mm, allis traumanil jaw tissue forceps,255mm, airway (metalic)size(0-4)set of 5,230mm, ambubag(siliconised)adult and paediatric with accessories, amputation set, american pattem suction tip with stillet,size:3, american pattem suction tip with stillet,size:4, artery forcep 8"(straight), artery forcep 8"(curved), auto b.p calf, artery forcep toothted, artery forcep plain, artery forcep small, ash ureter forceps with araumatic jaw,240mm, ayre cone knives for ring biopsy-230mm, babcock tissue grasping forcep 180mm, babcock tissue grasping forcep 200mm, babcock tissue grasping forcep 150mm, babcock tissue grasping forcep 10mmx310mm, babcock tissue grasping forcep 10mmx370mm, bandage cutting scissor, b.p handle no 3 long, b.p handle no 4 long, b.p handle no.4, b.p handle,200mm no.8, boycles apparatos, braun obstetrical forceps,305mm, boyer craniotomy forceps slightly curved-290mm, bozemann uretine dressing forceps straight 230mm, bozemann uterine dressing forceps with longitudinal groove-250, castroviejo needle holder with catch t/c tip,180mm, cusco vaginal specullam small,90mmx25mm, cord clamp, d & c set, davis boyels mouth gag. 5 tongue blades, davis boyels mouth gag with anaes tube , 5 tongue blades, debakey needle holder standard t/c tip,250mm, defibrillator specification a) biphasic low energy current based b) 4ed mode as well as manual defibrillation and pacing . c) wide range of energy selection 1 to 200 joules.d) must have synchronized cardio version capability .e) 3 lead ecg monitoring f) adult and pediatric padles, g) >5" colour display. h) ecg analysis system. i) light weight j) lithium battery with functioning for >2 hrs after charging.k) iso/ce certified, doyens mouth gag.100 mm, dressing scissors sharp x sharp straight 180 mm, dressing scissors sharp x sharp curved 180 mm, dressing scissors sharp x blunt straight 125 mm, dressing scissors sharp x blunt straight 180mm, dressing scissors sharp x blunt curved 180mm, deavers abdominal retractor adult 12mm,300mm, deavers abdominal retractor adult 25mm,300mm, deavers abdominal retractor adult 15mm,300mm, deavers abdominal retractor adult 50mm,300mm, deavers abdominal retractor adult 38mm,300mm, deavers abdominal retracror adult 75mm,300mm, desjardins gall bladder forceps,225mm, desjardins gall bladder forceps,240 mm, doyens retractor 40mm x60mm,230mm, delivery set, episiotomy scissor, electric cautery machine,specification no of bipolar modes available:2 bipoler current meter: yes power efficiency :98 or more available of advance cutting modes for skin incision type of display :led no of segments of display:7 warrenty (option of comprehensive warranty is available through bidding only,which if opted will supersede normal warranty in the catalogue):3 or more monoplolar foot switch supplied :1 bipolar foot switch :1 hand swithcing pencil:reusable patient plate: reusable bipolar forceps:1 forceps cord:1 universal adoptor :1 type of output of elctro surgical generator monopolar and biopolar outputs designed for all surgical procedure including general surgery,gynecology ,minimal invasive surgery,orthopaedic and oral surgery machine should be able ot monior changes in tissue impedance continuously and adjusts power :yes
Tender For providing of testing service for on-board /commissioned equipment/ instrument related to plant - civil; penetrant testing facility, specific gravity, moisture content, ph, atterberg limits , soil/particle grain size using sieve/hydrometer analysis, shrinkage lim..
Tender For supply of laboratory and scientific equipment - laboratory and scientific equipment, thermogravimetric analysis-differential scanning calorimetry (tga-dsc) instrument with 03 years warranty(details as per annexure-a), comprehensive maintenance contract (cmc) charges for thermogravimetric analysis-differential scanning calorimetry (tga-dsc) instrument for 3 years(details as per annexure-a)